Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

38 results
Display

Comparison of Temperatures of the Resin Cement in Polycrystalline Ceramic Brackets Irradiated Using a Diode Laser

Son YT, Son K, Kim KM, Lee JM, Kim JW, Yu W, Lee KB

Purpose: The primary objective of this study was to evaluate the change in the temperature of the adhesive resin in polycrystalline ceramic brackets irradiated using a diode laser at different...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of repeated use of an implant handpiece on an output torque: An in-vitro study

Son K, Son YT, Kim JY, Lee JM, Yu WJ, Kim JW, Lee KB

Purpose This study aimed to evaluate the effect of repeated use of an implant handpiece under an implant placement torque (35 Ncm) and overloading torque condition (50 Ncm) on an...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Marginal and internal fit of interim crowns fabricated with 3D printing and milling method

Son YT, Son K, Lee KB

Purpose: The purpose of this study was to assess the marginal and internal fit of interim crowns fabricated by two different manu-facturing method (subtractive manufacturing technology and additive manufacturing technology)....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical usefulness of post-operative 18F-fluorodeoxyglucose positron emission tomography-computed tomography in canine hemangiosarcoma

Lee G, Kwon SY, Son K, Park S, Lee JH, Cho KO, Min JJ, Choi J

This report describes the usefulness of positron emission tomography-computed tomography (PET-CT) for evaluating recurrent or residual tumors following surgery. CT and 18F-fluorodeoxyglucose PET-CT were pre- and post-operatively applied to multiple...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of occlusal load on the stress distribution of four cavity configurations of noncarious cervical lesions: a three-dimensional finite element analysis study

Jeon SJ, Park JK, Kim HC, Woo SG, Kim KH, Son K, Hur B

The objective of this study was to investigate the effect of excessive occlusal loading on stress distribution on four type of cervical lesion, using a three dimensional finite element analysis...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Stress distribution of endodontically treated maxillary second premolars restored with different methods: Three-dimensional finite element analysis

Lim DY, Kim HC, Hur B, Kim KH, Son K, Park JK

The purpose of this study was to evaluate the influence of elastic modulus of restorative materials and the number of interfaces of post and core systems on the stress distribution...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Temperature change and performance of bur efficiency for two different drill combinations

Hwang-Bo H, Park JY, Lee SY, Son K, Lee KB

Purpose. The purpose of this study was to evaluate the performance efficiency of two different drill combinations according to the heat generated and drilling time. Materials and methods. In this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of occlusal load on the cervical stress distribution: A three-dimensional finite element study

Lee HM, Hur B, Kim HC, Woo SG, Kim KH, Son K, Park JK

The objective of this study was to investigate the effects of various occlusal loads on the stress distribution of the buccal cervical region of a normal maxillary second premolar, using...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of the volumetric dimensions of a complete arch on the accuracy of scanners

Kim MK, Son K, Yu BY, Lee KB

PURPOSE The present study aimed to evaluate the accuracy of a desktop scanner and intraoral scanners based on the volumetric dimensions of a complete arch. MATERIALS AND METHODS Seven reference...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of repeated learning for two dental CAD software programs

Son K, Lee WS, Lee KB

PURPOSE: The purpose of this study is to assess the relationship between the time spent designing custom abutments and repeated learning using dental implant computer aided design (CAD) software. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Dose Distribution Using a Radiophotoluminescence Glass Dosimeter in Biobeam8000 Gamma Irradiation Device

Shin SH, Lee S, Son K, Lee HH, Kim KB, Jung H, Ji YH

  • KMID: 1451806
  • Korean J Med Phys.
  • 2011 Dec;22(4):198-205.
Gamma irradiator is widely used for cell, animal experiment, irradiation for blood, dose measurement, and education. Biobeam8000 gamma irradiator (STS Steuerungstechnik &. Strahlenschutz GmbH, Braunschweig, Germany, Cs137, 81.4 TBq) that...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Accuracy of different electronic torque drivers: A comparative evaluation

Ko BD, Son K, Kang SH, Lee KB

PURPOSE: This study aims to evaluate the loosening torque on the implant fixture, and to assess the accuracy of difference electronic torque drivers. MATERIALS AND METHODS: Three electronic torque drivers were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparative study of the improvement after different self-assessment methods of tooth preparation

Kim J, Son K, Lee KB

PURPOSE: The purpose of this study was to compare the degree of tooth preparation abilities of students according to three self-assessment methods. MATERIALS AND METHODS: forty-eight sophomores in Kyungpook National University...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluating usability of and satisfaction with two types of dental CAD software

Kim SM, Lee WS, Son K, Lee KB

PURPOSE: This study evaluated the usability of and satisfaction with two types of computer-aided design (CAD) software among users who had experience with dental implant CAD software and those who...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the accuracy of intraoral scanner by three-dimensional analysis in single and 3-unit bridge abutment model: In vitro study

Huang MY, Son K, Lee WS, Lee KB

PURPOSE: The purpose of this study was to evaluate the accuracy of three types of intraoral scanners and the accuracy of the single abutment and bridge abutment model. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Surface Treatment Technique for Interim Crown Fabricated by Three-Dimensional Printing with Digital Light-Processing Technology

Son K, Lee J, Lee KB

Purpose: The technique introduced in this study describes a technique for surface treatment that applies a photocuring resin to the surface of an interim crown fabricated by three-dimensional (3D) printing...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative study of two CAD software programs on consistency between custom abutment design and the output

Lim HM, Lee KB, Lee WS, Son K

PURPOSE: This study was aimed to compare the consistency between the custom abutment design and the output in two CAD software programs. MATERIALS AND METHODS: Customized abutments were designed by using...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluating Accuracy according to the Evaluator and Equipment Using Electronic Apex Locators

Yu BY, Son K, Lee KB

Purpose: Using two types of electronic apex locators, this study aimed to investigate the differences in accuracy according to the evaluator and equipment. Materials and Methods: Artificial teeth of the lower...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Displacement of scan body during screw tightening: A comparative in vitro study

Kim J, Son K, Lee KB

PURPOSE The purpose of this study was to evaluate the occurrence of displacement while tightening the screw of scan bodies, which were compared according to the material type. MATERIALS AND METHODS Three...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of machining precision of single ceramic restorations on the marginal and internal fit

Son K, Yu BY, Lee KB

Purpose: The purpose of this study was to evaluate the machining precision and the marginal and internal fit of single restorations fabricated with three types of lithium disilicate ceramic blocks...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr