Korean J Thorac Cardiovasc Surg.  2006 May;39(5):354-358.

The Comparative Study of on Pump CABG during Pulsatile (T-PLS(TM)) and Nonpulsatile (Bio-pump(TM)) Perfusion

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, College of Medicine, Soonchunhyang University, Korea. yswon@schbc.ac.kr

Abstract

BACKGROUND: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine the risks and benefits of T-PLS(TM) through the comparison of clinical effects of T-PLS(TM) (pulsatile pump) and Bio-pump(TM) (non-pulsatile pump) used for coronary bypass surgery. MATERIAL AND METHOD: The comparison was made on 40 patients who had coronary bypass using T-PLS(TM) and Bio-pump(TM) (20 patients for each) from April 2003 to June 2005. All of the surgeries were operated on pump beating coronary artery bypass graft using cardiopulmonary extra-corporeal circulation. Risk factors before surgery and the condition during surgery and the results were compared. RESULT: There was no significant difference in age, gender ratio, and risk factors before surgery such as history of diabetes, hypertension, smoking, obstructive pulmonary disease, coronary infarction, and renal failure between the two groups. Surgery duration, hours of heart-lung machine operation, used shunt and grafted coronary branch were little different between the two groups. The two groups had a similar level of systolic arterial pressure, diastolic arterial pressure and mean arterial pressure, but pulse pressure was measured higher in the group with T-PLS(TM) (46+/-15 mmHg in T-PLS(TM) vs 35+/-13 mmHg in Bio-pump(TM), p<0.05). The T-PLS(TM)-operated patients tended to produce more urine volume during surgery, but the difference was not statistically significant (9.7+/-3.9 cc/min in T-PLS(TM) vs 8.9+/-3.6 cc/min in Bio-pump(TM), p=0.20). There was no significant difference in mean duration of respirator usage and 24-hour blood loss after surgery between the two groups. Plasma free Hb was measured lower in the group with T-PLS(TM) (24.5+/-21.7 mg/dL in T-PLS(TM) versus 46.8+/-23.0 mg/dL in Bio-pump(TM), p<0.05). There was no significant difference in coronary infarction, arrhythmia, renal failure and morbidity rate of cerebrovascular disease. There was a case of death after surgery (death rate of 5%) in the group tested with T-PLS(TM), but the death rate was not statistically significant.
CONCLUSION
Coronary bypass was operated with T-PLS(TM) (Pulsatile flow pump) using a heart-lung machine. There was no unexpected event caused by mechanical error during surgery, and the clinical process of the surgery was the same as the surgery for which Bio-pump(TM) was used. In addition, T-PLS(TM) used surgery was found to be less detrimental to blood corpuscles than the pulsatile flow has been known to be. Authors of this study could confirm the safety of T-PLS(TM).

Keyword

Coronary artery bypass; Cardiopulmonary bypass; Pulsatile flow; Perfusion

MeSH Terms

Arrhythmias, Cardiac
Arterial Pressure
Blood Cells
Blood Pressure
Cardiopulmonary Bypass
Coronary Artery Bypass
Extracorporeal Circulation
Heart-Lung Machine
Humans
Hypertension
Infarction
Lung Diseases, Obstructive
Mortality
Perfusion*
Plasma
Pulsatile Flow
Renal Insufficiency
Risk Assessment
Risk Factors
Smoke
Smoking
Transplants
Ventilators, Mechanical
Smoke
Full Text Links
  • KJTCS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr