Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

36 results
Display

Modelling of Elastic Blood Vessel under the Pulsatile Flow

Suh SH, Roh HW, Yoo SS, Kim DI, Lee BB

  • KMID: 2096765
  • J Korean Soc Vasc Surg.
  • 1999 Nov;15(2):213-217.
PURPOSE: Characteristics of pulsatile flow in 3-dimensional arterial geometry and elastic vessel wall should be investigated in order to understand the physiological blood flow in human body. In this study,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
PID controller design to generate pulsatile flow rate for in vitro experimental studies of physiological flows

Najjari MR, Plesniak M

Producing accurate pulsatile flow rates is essential for many in vitro experimental studies in biofluid dynamics research. A controller system was developed to control a flow loop to produce easily...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow

Son HS, Fang YH, Hwang Z, Min BJ, Cho JH, Park SM, Lee SH, Kim KT, Sun K

  • KMID: 2393739
  • Korean J Thorac Cardiovasc Surg.
  • 2005 Feb;38(2):101-109.
BACKGROUND: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Visualization of Pulsatile Flow of the Blood Substitute Fluids Using the Particle Image Velocimetry

Suh SH, Roh HW, Yoo SS, Kim DI, Lee BB

  • KMID: 2096764
  • J Korean Soc Vasc Surg.
  • 1999 Nov;15(2):205-212.
PURPOSE: The objective of the present study is to investigate the steady and pulsatile flow phenomena of the blood substitute fluids in the circular and bifurcated vessels numerically and experimentally....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Pulsatile Versus Nonpulsatile Blood Flow on Renal Tissue Perfusion in Extracorporeal Circulation

Kim HK, Son HS, Fang YH, Park SY, Kim KT, Sun K, Kim HJ

  • KMID: 2393753
  • Korean J Thorac Cardiovasc Surg.
  • 2005 Jan;38(1):13-22.
BACKGROUND: It has been known that pulsatile flow is physiologic and more favorable to tissue perfusion than nonpulsatile flow. The purpose of this study is to directly compare the effect...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study of Doppler Waveform Using Pulsatile Flow Model

Chung HW, Chung MJ, Park JH, Chung JW, Lee DH, Min BG

  • KMID: 2201482
  • J Korean Radiol Soc.
  • 1997 Aug;37(2):225-232.
PURPOSE: Through the construction of a pulsatile flow model using an artificial heart pump and stenosis to demonstrate triphasic Doppler waveform, which simulates in vivo conditions, and to evaluate the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Oral Administration of Cilostazol Increases Ocular Blood Flow in Patients with Diabetic Retinopathy

Hwang DJ, Shin JY, Yu HG

PURPOSE: To investigate the effect of cilostazol on ocular hemodynamics and to determine whether the administration of cilostazol increases the ocular blood flow in patients with diabetic retinopathy. METHODS: This prospective...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Computed numerical analysis of the biomechanical effects on coronary atherogenesis using human hemodynamic and dimensional variables

Lee BK, Kwon HM, Kim D, Yoon YW, Seo JK, Kim IJ, Roh HW, Suh SH, Yoo SS, Kim HS

The objectives of this investigation were to evaluate biomechanical factors in the atherosclerotic process using human in vivo hemodynamic parameters and computed numerical simulation qualitatively and quantitatively. The three-dimensional spatial...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Application of the Pulsatile Cardiopulmonary Bypass in Animal Model

Shin HK, Won YS, Lee JY, Her K, Yeum Y, Kim SC, Min BG

  • KMID: 1885884
  • Korean J Thorac Cardiovasc Surg.
  • 2004 Jan;37(1):1-10.
BACKGROUND: Currently, the cardiopulmonary machine with non-pulsatile pumps, which are low in internal circuit pressure and cause little damage to blood cells, is widely used. However, a great number of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Usefulness of Pulsatile Flow Detection in Measuring Resistive Index in Renal Doppler US

Kim SH

OBJECTIVE: To assess the usefulness of pulsatile flow detection (PFD), a newly developed function of color Doppler US, in measuring resistive index (RI) in renal Doppler US and to compare...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pulsatile Ocular Blood Flow in Healthy Koreans

Kim SK, Cho BJ, Hong S, Kang SY, Kim JS, Kim CY, Seong GJ

PURPOSE: To determine the normal reference range of pulsatile ocular blood flow (POBF) values in healthy Korean subjects and to find out the factors that may affect them. METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of Pulsatile Versus Nonpulsatile Blood Flow on Viscoelasticity and Red Blood Cell Aggregation in Extracorporeal Circulation

Ahn CB, Kang YJ, Kim MG, Yang S, Lim CH, Son HS, Kim JS, Lee SY, Son KH, Sun K

BACKGROUND: Extracorporeal circulation (ECC) can induce alterations in blood viscoelasticity and cause red blood cell (RBC) aggregation. In this study, the authors evaluated the effects of pump flow pulsatility on...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Treatment of Advanced Heart Failure: Beyond Medical Treatment

Choi JO

  • KMID: 2263519
  • Korean J Med.
  • 2012 Jun;82(6):658-666.
During last 2 decades, advance in the mechanical circulatory support has altered the management of end-stage heart failure and cardiogenic shock. This includes percutaneous mechanical support devices such as extracorporeal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Applications of Cine MR

Song KY, Ha YI, Kang DS, Park JH, Choi SW

  • KMID: 2067547
  • J Korean Neurosurg Soc.
  • 1998 Jun;27(6):808-814.
Evaluation of intracranial CSF flow was accomplished by the use of cine MR technique. In the cine MR, there were two methods of evaluation in CSF flow pattern. Qualitative and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Comparative Study of on Pump CABG during Pulsatile (T-PLS(TM)) and Nonpulsatile (Bio-pump(TM)) Perfusion

Park YW, Her K, Lim JU, Shin HK, Won YS

  • KMID: 2289160
  • Korean J Thorac Cardiovasc Surg.
  • 2006 May;39(5):354-358.
BACKGROUND: Pulsatile pumps for extracorporeal circulation have been known to be better for tissue perfusion than non-pulsatile pumps but be detrimental to blood corpuscles. This study is intended to examine...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparative Study of Nonpulsatile and Pulsatile Perfusion on Hemodynamics and Renal Function Centered on the patients undergoing coronary artery bypass grafting with cardiopulmonary bypass

Shim YH, Lee HH, Lee CS, Park JH, Hong YW, Kwak YL

BACKGROUND: It has been widely believed that pulsatile flow was better than nonpulsatile flow. However it remains uncertain whether pulsatile perfusion has shown substantive clinical improvement compared to standard, nonpulsatile...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
MR Angiography of Stenosis and Aneurysm Models in the Pulsatile Flow: Variation with Imaging Parameters and Concentration of Contrast Media

Park KJ, Park JH, Lee HJ, Won HJ, Lee DH, Min BG, Chang KH

  • KMID: 2025466
  • J Korean Radiol Soc.
  • 1997 Nov;37(5):801-811.
PURPOSE: The image quality of magnetic resonance angiography (MRA) varies according to the imaging techniques applied and the parameters affected by blood flow patterns, as well as by the shape...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Factors Affecting the Renal Doppler Waveform with the Use of an Electrical Circuit Model

Sung CK, Han BS, Kim SH

  • KMID: 1472119
  • J Korean Soc Ultrasound Med.
  • 2009 Jun;28(2):75-82.
PURPOSE: We have evaluated the influence of several variables such as vascular compliance and resistance and heart rate on the resistive index by the use of an electrical circuit model...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Factors influencing the renal arterial Doppler waveform: a simulation study using an electrical circuit model (secondary publication)

Sung CK, Han BS, Kim SH

PURPOSE: The goal of this study was to evaluate the effect of vascular compliance, resistance, and pulse rate on the resistive index (RI) by using an electrical circuit model to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Orbital Doppler Evaluation of Blood Flow Velocities in Optic Neuritis

Karami M, Janghorbani M, Dehghani A, Riahinejad M

PURPOSE: To evaluate orbital blood flow velocities and optic nerve diameter with Doppler and gray-scale sonography in patients with acute unilateral optic neuritis (ON). METHODS: Orbital Doppler and gray-scale sonography was...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr