Korean Circ J.  2013 May;43(5):303-308. 10.4070/kcj.2013.43.5.303.

Comparison of Two Different Strategies of Intravascular Ultrasound Guidance during Percutaneous Coronary Intervention; Routine versus Selective

Affiliations
  • 1Department of Internal Medicine, Cardiovascular Center, Seoul National University Hospital, Seoul, Korea. hyosoo@snu.ac.kr

Abstract

BACKGROUND AND OBJECTIVES
Intravascular ultrasound (IVUS) is helpful during percutaneous coronary intervention (PCI), because it can be used to confirm good apposition or optimal expansion of stents. In this study, we compared angiographic result as well as clinical outcomes between two different strategies of IVUS-guidance, the selective vs. the routine.
SUBJECTS AND METHODS
The study population consisted of 279 patients undergoing electric and emergency intracoronary implatation of TAXUS stent from August 2003 through September 2006. For this study, we divided physicians into two groups; doctors to perform PCI under 'routine' IVUS-guidance vs. PCI under 'selective' IVUS-guidance. Among a total of 279 patients (384 lesions) who underwent PCI with TAXUS stent, 87 patients underwent the procedure under the strategy of 'routine' IVUS-guidance, whereas 192 patients under 'selective' IVUS-guidance.
RESULTS
The baseline clinical features of the patients are similar between the two groups. The actual rate of IVUS usage was 89.2% in the routine group and 68.2% in the selective group (p<0.01). A high rate of adjunctive ballooning was determined as a remarkable procedure-related parameter which was comparable between the two groups (72.5% vs. 76.1% in routine vs. selective, p=0.57). The minimal lumen diameter at immediate post-PCI was significantly larger in the routine IVUS group than that in the selective group (2.58 mm vs. 2.48 mm, p=0.03). However, the difference disappeared during the follow-up period (1.98 mm vs. 1.98 mm, p=0.94). Clinical outcomes at 1 year were not different between the two groups.
CONCLUSION
PCI under the strategy of 'selective' IVUS-guidance was comparable to PCI under 'routine' IVUS-guidance in terms of angiographic and clinical outcomes in circumstances with frequent use of adjunctive ballooning after stenting.

Keyword

Ultrasonography, interventional; Drug-eluting stents; Dilatation, percutaneous coronary intervention

MeSH Terms

Drug-Eluting Stents
Emergencies
Follow-Up Studies
Humans
Percutaneous Coronary Intervention
Stents
Taxus
Ultrasonography, Interventional

Reference

1. St Goar FG, Pinto FJ, Alderman EL, Fitzgerald PJ, Stadius ML, Popp RL. Intravascular ultrasound imaging of angiographically normal coronary arteries: an in vivo comparison with quantitative angiography. J Am Coll Cardiol. 1991; 18:952–958.
2. Tobis JM, Mallery JA, Gessert J, et al. Intravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro. Circulation. 1989; 80:873–882.
3. Baptista J, di Mario C, Escaned J, et al. Intracoronary two-dimensional ultrasound imaging in the assessment of plaque morphologic features and the planning of coronary interventions. Am Heart J. 1995; 129:177–187.
4. Gussenhoven EJ, Essed CE, Lancée CT, et al. Arterial wall characteristics determined by intravascular ultrasound imaging: an in vitro study. J Am Coll Cardiol. 1989; 14:947–952.
5. Tobis JM, Mallery J, Mahon D, et al. Intravascular ultrasound imaging of human coronary arteries in vivo. Analysis of tissue characterizations with comparison to in vitro histological specimens. Circulation. 1991; 83:913–926.
6. Nakamura S, Mahon DJ, Maheswaran B, Gutfinger DE, Colombo A, Tobis JM. An explanation for discrepancy between angiographic and intravascular ultrasound measurements after percutaneous transluminal coronary angioplasty. J Am Coll Cardiol. 1995; 25:633–639.
7. Kastrati A, Dibra A, Mehilli J, et al. Predictive factors of restenosis after coronary implantation of sirolimus- or paclitaxel-eluting stents. Circulation. 2006; 113:2293–2300.
8. Pfisterer M, Brunner-La Rocca HP, Buser PT, et al. Late clinical events after clopidogrel discontinuation may limit the benefit of drug-eluting stents: an observational study of drug-eluting versus bare-metal stents. J Am Coll Cardiol. 2006; 48:2584–2591.
9. Carrozza JP Jr, Kuntz RE, Levine MJ, et al. Angiographic and clinical outcome of intracoronary stenting: immediate and long-term results from a large single-center experience. J Am Coll Cardiol. 1992; 20:328–337.
10. Cavaye DM, White RA. Intravascular ultrasound imaging: development and clinical applications. Int Angiol. 1993; 12:245–255.
11. Daemen J, Wenaweser P, Tsuchida K, et al. Early and late coronary stent thrombosis of sirolimus-eluting and paclitaxel-eluting stents in routine clinical practice: data from a large two-institutional cohort study. Lancet. 2007; 369:667–678.
12. Fitzgerald PJ, Oshima A, Hayase M, et al. Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study. Circulation. 2000; 102:523–530.
13. Oemrawsingh PV, Mintz GS, Schalij MJ, Zwinderman AH, Jukema JW, van der Wall EE. TULIP Study. Thrombocyte activity evaluation and effects of Ultrasound guidance in Long Intracoronary stent Placement. Intravascular ultrasound guidance improves angiographic and clinical outcome of stent implantation for long coronary artery stenoses: final results of a randomized comparison with angiographic guidance (TULIP Study). Circulation. 2003; 107:62–67.
14. Schiele F, Meneveau N, Seronde MF, et al. Medical costs of intravascular ultrasound optimization of stent deployment. Results of the multicenter randomized 'REStenosis after Intravascular ultrasound STenting' (RESIST) study. Int J Cardiovasc Intervent. 2000; 3:207–213.
15. Mudra H, di Mario C, de Jaegere P, et al. Randomized comparison of coronary stent implantation under ultrasound or angiographic guidance to reduce stent restenosis (OPTICUS Study). Circulation. 2001; 104:1343–1349.
16. Roy P, Steinberg DH, Sushinsky SJ, et al. The potential clinical utility of intravascular ultrasound guidance in patients undergoing percutaneous coronary intervention with drug-eluting stents. Eur Heart J. 2008; 29:1851–1857.
17. Russo RJ, Silva PD, Teirstein PS, et al. A randomized controlled trial of angiography versus intravascular ultrasound-directed bare-metal coronary stent placement (the AVID Trial). Circ Cardiovasc Interv. 2009; 2:113–123.
18. Orford JL, Denktas AE, Williams BA, et al. Routine intravascular ultrasound scanning guidance of coronary stenting is not associated with improved clinical outcomes. Am Heart J. 2004; 148:501–506.
19. Choi JW, Goodreau LM, Davidson CJ. Resource utilization and clinical outcomes of coronary stenting: a comparison of intravascular ultrasound and angiographical guided stent implantation. Am Heart J. 2001; 142:112–118.
20. Rogacka R, Latib A, Colombo A. IVUS-Guided Stent Implantation to Improve Outcome: A Promise Waiting to be Fulfilled. Curr Cardiol Rev. 2009; 5:78–86.
21. Hong MK, Mintz GS, Lee CW, et al. Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation. Eur Heart J. 2006; 27:1305–1310.
22. Fujii K, Mintz GS, Kobayashi Y, et al. Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for instent restenosis. Circulation. 2004; 109:1085–1088.