J Korean Soc Radiol.  2012 Aug;67(2):85-92. 10.3348/jksr.2012.67.2.85.

Usefulness of Biphasic Contrast Injection in Multidetector CT of the Head and Neck: A Comparison with Monophasic Contrast Injection

Affiliations
  • 1Department of Radiology, Kyung Hee University Hospital at Gangdong, Kyung Hee University School of Medicine, Seoul, Korea. md.cwryu@gmail.com
  • 2Department of Radiology, Kyung Hee University Medical Center, Kyung Hee University School of Medicine, Seoul, Korea.

Abstract

PURPOSE
The purpose of this study was to evaluate the value of biphasic injection of contrast media in a CT of the head and neck.
MATERIALS AND METHODS
In the first step, vessel and tissue attenuation was measured in four different protocol groups: M1 (monophasic, injection rate: 100 mL at 3 mL/sec, delay time: 70 sec); B1 (biphasic, 100 mL at 3 mL/sec, 70 sec); M2 (monophasic, 100 mL at 2 mL/sec, 70 sec); and B2 (biphasic, 100 mL at 2 mL/sec, 120 sec). The biphasic injection protocol was an initial volus injection of 50 mL contrast medium and an additional volus injection of 50 mL contrast medium at 35 sec after initial injection. In the second step, the tissue attenuation of two groups was measured with a different contrast media volume and phase: M3 (monophasic, 100 mL at 2 mL/sec, 90 sec) and B3 (biphasic, 80 mL at 2 mL/sec, 90 sec, initial volus injection of 40 mL and an additional volus injection of 40 mL at 55 sec after initial injection). The measured CT numbers from vessels and tissues were compared between the different protocol groups.
RESULTS
The vessel attenuation of B1 was higher than that of M1 and B2 (p < 0.05). Despite a longer delay time, the vessel attenuation of B2 was not significantly different from that of M1 and M2. There was no significant differentiation of tissue attenuation between each group. In the second study, the attenuation of vessel and tissue was not different between B3 and M3.
CONCLUSION
Biphasic contrast injection leads to an increased attenuation of the vessel and also delays the optimal scan window.


MeSH Terms

Contrast Media
Glycosaminoglycans
Head
Resin Cements
Contrast Media
Glycosaminoglycans
Resin Cements

Reference

1. Harris EW, LaMarca AJ, Kondroski EM, Murtagh FR, Clark RA. Enhanced CT of the neck: improved visualization of lesions with delayed imaging. AJR Am J Roentgenol. 1996. 167:1057–1058.
2. Imhof H, Czerny C, Dirisamer A. Head and neck imaging with MDCT. Eur J Radiol. 2003. 45:Suppl 1. S23–S31.
3. Kalra MK, Maher MM, D'Souza R, Saini S. Multidetector computed tomography technology: current status and emerging developments. J Comput Assist Tomogr. 2004. 28:Suppl 1. S2–S6.
4. Groell R, Doerfler O, Schaffler GJ, Habermann W. Contrast-enhanced helical CT of the head and neck: improved conspicuity of squamous cell carcinoma on delayed scans. AJR Am J Roentgenol. 2001. 176:1571–1575.
5. Keberle M, Tschammler A, Hahn D. Single-bolus technique for spiral CT of laryngopharyngeal squamous cell carcinoma: comparison of different contrast material volumes, flow rates, and start delays. Radiology. 2002. 224:171–176.
6. Awai K, Imuta M, Utsunomiya D, Nakaura T, Shamima S, Kawanaka K, et al. Contrast enhancement for whole-body screening using multidetector row helical CT: comparison between uniphasic and biphasic injection protocols. Radiat Med. 2004. 22:303–309.
7. Cademartiri F, Luccichenti G, Marano R, Gualerzi M, Brambilla L, Coruzzi P. Comparison of monophasic vs biphasic administration of contrast material in non-invasive coronary angiography using a 16-row multislice computed tomography. Radiol Med. 2004. 107:489–496.
8. Fleischmann D, Rubin GD, Bankier AA, Hittmair K. Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography. Radiology. 2000. 214:363–371.
9. Rutten A, Meijs MF, de Vos AM, Seidensticker PR, Prokop M. Biphasic contrast medium injection in cardiac CT: moderate versus high concentration contrast material at identical iodine flux and iodine dose. Eur Radiol. 2010. 20:1917–1925.
10. Bartz BH, Case IC, Srinivasan A, Mukherji SK. Delayed MDCT imaging results in increased enhancement in patients with head and neck neoplasms. J Comput Assist Tomogr. 2006. 30:972–974.
11. Silverman PM. Lymph node imaging: multidetector CT (MDCT). Cancer Imaging. 2005. 5 Spec No A:S57–S67.
12. Dawson P. Multi-slice CT contrast enhancement regimens. Clin Radiol. 2004. 59:1051–1060.
13. Vidiri A, Guerrisi A, Pellini R, Manciocco V, Covello R, Mattioni O, et al. Multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) in the evaluation of the mandibular invasion by squamous cell carcinomas (SCC) of the oral cavity. Correlation with pathological data. J Exp Clin Cancer Res. 2010. 29:73.
14. Nemec SF, Linecker A, Czerny C, Imhof H, Krestan CR. Detection of cutaneous invasion by malignant head and neck tumors with MDCT. Eur J Radiol. 2008. 68:335–339.
15. Preda L, Lovati E, Chiesa F, Ansarin M, Cattaneo L, Fasani R, et al. Measurement by multidetector CT scan of the volume of hypopharyngeal and laryngeal tumours: accuracy and reproducibility. Eur Radiol. 2007. 17:2096–2102.
Full Text Links
  • JKSR
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr