Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

54 results
Display

Successful management of absent sternum in an infant using porcine acellular dermal matrix

Semlacher , Nuri MA

Congenital absent sternum is a rare birth defect that requires early intervention for optimal long-term outcomes. Descriptions of the repair of absent sternum are limited to case reports, and no...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Utility of a modified components separation for abdominal wall reconstruction in the liver and kidney transplant population

Black CK, Zolper EG, Walters ET, Wang J, Martinez J, Tran A, Naz I, Kotha V, Kim PJ, Sher SR, Evans KK

BACKGROUND: Incisional hernia is a common complication following visceral organ transplantation. Transplant patients are at increased risk of primary and recurrent hernias due to chronic immune suppression and large incisions....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Recurrent Urinary Tract Infection from Urethral Mesh Erosion after Midurethral Mesh Sling Surgery

Han JY

This paper presents three cases of recurrent urinary tract infections from urethral mesh erosion after transobturator midurethral sling (MUS) surgery. The patients were operated on using a MUS with a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Current surgical management of pelvic organ prolapse: Strategies for the improvement of surgical outcomes

Ko KJ, Lee KS

There are a variety of surgical management strategies to help surgeons repair pelvic organ prolapse (POP). Surgical treatment for POP includes native tissue repair, augmentation with mesh, and minimally invasive...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Treatment of Anterior Vaginal Wall Prolapse Using Transvaginal Anterior Mesh With Apical Fixation: A Prospective Multicenter Study With up to 2 Years of Follow-up

Palma PC, de Castro Monteiro MV, Ledesma MA, Altuna S, Sardi JJ, Riccetto C

PURPOSE: To evaluate the safety and efficacy of a surgical polypropylene mesh for correction of anterior vaginal prolapse, with or without apical defects, by providing simultaneous reinforcement at the anterior...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Short-term outcomes of the transvaginal minimal mesh procedure for pelvic organ prolapse

Takazawa N, Fujisaki A, Yoshimura , Tsujimura , Horie S

PURPOSE: This study aimed to evaluate the clinical outcomes and complications of transvaginal minimal mesh repair without using commercially available kits for treatment of pelvic organ prolapse (POP). MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An evaluation of the Manufacturer And User Facility Device Experience database that inspired the United States Food and Drug Administration's Reclassification of transvaginal mesh

Sandberg J, Gray I, Pearlman A, Terlecki R

PURPOSE: To assess the utility of the Manufacturer And User Facility Device Experience (MAUDE) database in objectively capturing adverse events for transvaginal mesh in the United States. MATERIALS AND METHODS: We...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of partially-absorbable lightweight mesh with heavyweight mesh for inguinal hernia repair: multicenter randomized study

Lee SD, Son T, Lee JB, Chang YS

PURPOSE: Prosthetic mesh is widely used for inguinal hernia repair; however, pain and stiffness can develop. This study was a prospective, multicenter, single-blind, randomized trial to assess postoperative pain and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Efficacy and safety of a novel partially absorbable mesh in totally extraperitoneal hernia repair

Yang HW, Kang SH, Jung SY, Min BW, Lee SI

PURPOSE: Partially absorbable mesh has been introduced and used for inguinal hernia repair for the purpose of minimizing pain and improving abdominal wall compliance. In this study, we evaluate the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Parastomal hernias after radical cystectomy and ileal conduit diversion

Donahue TF, Bochner BH

Parastomal hernia, defined as an "incisional hernia related to an abdominal wall stoma", is a frequent complication after conduit urinary diversion that can negatively impact quality of life and present...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A clinical study on the trocar-guided mesh repair system for pelvic organ prolapse surgery

Bak SG, Moon JB, Hong SK, Kim KJ, Kim KA, Lee JH

OBJECTIVE: To evaluate the complication and recurrence rates in patients undergoing trocar-guided mesh implant for pelvic organ prolapse (POP) treatment. METHODS: A retrospective study was performed based on the medical records...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Wrapping Method for Inserting Titanium Micro-Mesh Implants in the Reconstruction of Blowout Fractures

Choi TJ, Burm JS, Yang WY, Kang SY

Titanium micro-mesh implants are widely used in orbital wall reconstructions because they have several advantageous characteristics. However, the rough and irregular marginal spurs of the cut edges of the titanium...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Coskun and Lichteinstein hernia repair methods for groin hernia

Dinc T, Cete HM, Saylam B, Ozer MV, Duzgun AP, Coskun F

PURPOSE: Coskun hernia repair technique has been reported to be an effective new fascia transversalis repair with its short-term follow-up results. Our aim is to determine the results of Coskun...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Simultaneous treatment of anterior vaginal wall prolapse and stress urinary incontinence by using transobturator four arms polypropylene mesh

Sharifiaghdas F, Daneshpajooh A, Mirzaei M

PURPOSE: To evaluate the medium-term efficacy and safety of transobturator four-arm polypropylene mesh in the treatment of high-stage anterior vaginal wall prolapse and concomitant stress urinary incontinence (SUI). MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Preliminary evaluation of a three-dimensional, customized, and preformed titanium mesh in peri-implant alveolar bone regeneration

Jung GU, Jeon JY, Hwang KG, Park CJ

OBJECTIVES: The purpose of this preliminary study is to evaluate the effectiveness of a customized, three-dimensional, preformed titanium mesh as a barrier membrane for peri-implant alveolar bone regeneration. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Correction of Congenital Metacarpal Synostosis with Polypropylene Mesh as an Interpositional Material

Kang HJ, Kwak YH

  • KMID: 2336297
  • J Korean Orthop Assoc.
  • 2013 Aug;48(4):314-318.
Metacarpal synostosis is an uncommon congenital hand malformation characterized by the coalescence of two or more adjacent metacarpals. Patients visit the hospital due to abduction deformity, which is usually a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Suitability of Absorbable Mesh Insertion for Oncoplastic Breast Surgery in Patients with Breast Cancer Scheduled to Be Irradiated

Kim T, Cho H

  • KMID: 2374550
  • J Breast Cancer.
  • 2013 Mar;16(1):84-89.
PURPOSE: The objective of this study was to investigate the influence of radiotherapy on the cosmetic outcome after immediate breast reconstruction using an absorbable mesh in breast cancer. METHODS: From July...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Management of Infected Mesh after Laparoscopic Incisional Hernia Repair

Lee GJ, Chung M

Laparoscopic repair using mesh is a standard technique for ventral hernia repair. Complications of laparoscopic ventral hernia repair increase according to the increment of laparoscopic repair. Subcutaneous emphysema and mesh...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the outcomes between laparoscopic totally extraperitoneal repair and prolene hernia system for inguinal hernia; review of one surgeon's experience

Choi YY, Han SW, Bae SH, Kim SY, Hur KY, Kang GH

PURPOSE: To compare the outcomes between laparoscopic total extraperitoneal (TEP) repair and prolene hernia system (PHS) repair for inguinal hernia. METHODS: A retrospective analysis of 237 patients scheduled for laparoscopic TEP...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Results from Over One Year of Follow-Up for Absorbable Mesh Insertion in Partial Mastectomy

Koo MY, Lee SK, Hur SM, Bae SY, Choi MY, Cho DH, Kim S, Choe JH, Kim JH, Kim JS, Lee JE, Nam SJ, Yang JH

PURPOSE: Recently, several clinicians have reported the advantages of simplicity and cosmetic satisfaction of absorbable mesh insertion. However, there is insufficient evidence regardint its long-term outcomes. We have investigated the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2021 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr