Korean J Thorac Cardiovasc Surg.  2010 Dec;43(6):602-613.

Measurement of Porcine Aortic and Pulmonary Valve Geometry and Design for Implantable Tissue Valve

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Seoul National University Hospital, Korea. kyj@plaza.snu.ac.kr
  • 2Department of Thoracic and Cardiovascular Surgery, Sejong General Hospital, Sejong Heart Institute, Korea.

Abstract

BACKGROUND
As life expectancy has been increased, the cardiac valve disease has been increased. In past, mechanical valve for valve replacement surgery was used widely, but it has many weaknesses, such as hemorrhage, teratogenic effect caused by warfarin, acute mechanical failure, taking warfarin during life, etc. So, the tissue valve is used widely and researches for durability of tissue valve are in progress. Tissue valves being used are all imported in Korea, and there is a lack of information on its geometry and design. So, we studied the geometry of porcine aortic and pulmonary valve, and tried to suggest theoretical basis for making the aortic and pulmonary valve. MATERIAL AND METHOD: We harvested aortic and pulmonary valves of 25 pigs and measured the geometry of valve at fresh and glutaraldehyde (GA) fixed state. In each group, we measured the diameter of the base, diameter of commissure, valve height, commissural height, etc. Also, for making implantable porcine and bovine pericardial valve, we designed the valve stent form, thickness, height, and leaflet size, form, thickness by different size of valve. RESULT: The aortic and pulmonary valve geometry and ratio were measured in each group. The right coronary cusp of aortic valve and right facing cusp of pulmonary valve was bigger than other cusps and non coronary cusp was smaller than others (RCC:NCC:LCC=1:0.88:1). Valve height was correlated to the leaflet size. We designed the outer diameter of stented porcine aortic valve from 19 mm to 33 mm and designed stent height and width, using previous measured ratio of each structure, stent thickness, working thickness (for making valve). Also, we designed the size of stent and form for stented bovine pericardial valve, considering diameter of valve, leaflet length, height and leaflet minimum coaptation area.
CONCLUSION
By measuring of 25 pig's aortic and pulmonary valve geometry and ratio, we can make theoretical basis for making implantable stented porcine valve and bovine pericardial valve in various size. After making implantable valve using these data, it is necessary to do in vivo and in vitro researches, furthermore.

Keyword

Tissue engineering; Valve; Design

MeSH Terms

Aortic Valve
Glutaral
Heart Valves
Hemorrhage
Korea
Life Expectancy
Pulmonary Valve
Stents
Swine
Tissue Engineering
Warfarin