Korean J Thorac Cardiovasc Surg.  2001 Apr;34(4):322-328.

Membranous PTFE Monocusp Valveon the Right Ventricular Outflo Tract

Affiliations
  • 1Department of Cardiovascular Surgery, Yonsei Cardiovascular Center, Yonsei Univeresity College of Medicine, Korea.
  • 2Department of Pediatric Cardiology, Yonsei Cardiovascular Center, Yonsei Univeresity College of Medicine, Korea.

Abstract

BACKGROUND: We studied the effect of membranous ePTFE(expanded polytetrafluoroethylene, Goretex) monocusp valve, known to lessen pseudointimal formation, on the right ventricular outflow tract(RVOT). MATERIAL AND METHOD: From May, 1996 to February, 1997, we operated 47 patients who received surgery on RVOT in whom we could measure the right ventricular pressure until the post-operative day 1. There were two groups: the comparative group with 19 patients using membranous Goretex monocusp valves and the ontrol group with 28 patients not using Goretex for the reconstruction of RVOT. Two groups did not show statistically significant differences in age, body weight, and McGoon ratio(p>0.05). The previous surgery was performed 19 times in the control group and 22 times in the comparative group. The RVOT reconstructions were performed by the methods of reparation a l'etage ventriculaire(REV) in 2 cases, RV to PA connection in 8 cases, redo-RVOT patch enlargement in 2, and RVOT patch enlargement in 16 cases of the control group. The comparative group had REV operation in 5 cases, Rastelli procedure in 6, redo-RVOT patch enlargement in 5, RVOT patch enlargement in 3 cases. RESULT: The comparative group showed significant difference shorter duration of indweling chest tube compared to the control group(p<0.04). No eminent significances were found on the aortic cross clamp time and the total bypass time. On the postoperative 7th day, right/left ventricular pressure ratio and RVOT pressure gradient were not different. During the follow-up, pulmonary insufficiency was significantly different between the two groups(p<0.04). One patient in the comparative group was died due to sepsis.
CONCLUSION
We found that the effects of membranous Goretex monocusp valve on the RVOT was good in early results with a reduced pulmonary insufficiency. Continuous long-term follow-up study should be performed on the matter of the membranow valve function and late stenosis.

Keyword

Ventricular outflow obstruction; Pulmonary valve; Polytetrafluoroethylene

MeSH Terms

Body Weight
Chest Tubes
Constriction, Pathologic
Follow-Up Studies
Humans
Polytetrafluoroethylene*
Pulmonary Valve
Sepsis
Ventricular Outflow Obstruction
Ventricular Pressure
Polytetrafluoroethylene
Full Text Links
  • KJTCS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr