Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

125 results
Display

Color stability of three dimensional-printed denture teeth exposed to various colorants

Koh ES, Cha HS, Kim TH, Ahn JS, Lee JH

PURPOSE: This study evaluated color stability of Dentca 3D-printed denture teeth, in comparison to color stabilities of four conventional types of denture teeth, upon being immersed in various colorants. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mechanical properties and biocompatibility of experimental 3D printing denture base resin

Park DR, Bae JM

This study was conducted to compare the flexural properties and biocompatibility of experimental 3D printing resins with commercial 3D-printing resins and conventional denture base resin. Auto polymerized pour-type denture base...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fabrication of additive manufacturing interim denture and comparison with conventional interim denture: A case report

Kim HA, Lim HP, Kang H, Yang H, Park SW, Yun KD

With development of digital dentistry, the 3-dimensional (3D) manufacturing industry using computer-aided design and computer-aided manufacturing (CAD/CAM) has grown dramatically in recent years. Denture fabrication using digital method is also...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Rehabilitation with implant-supported fixed dental prostheses using digital duplication technique on customized artificial tooth, interim denture and implant surgical template: A case report

Jeong DG, Oh KC, Shim JS, Park JM

Bone and soft tissue conditions are important for successful implant treatment. But, the placement itself is also very important. Implants which is installed in the wrong position result in the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative analysis of case series for the prosthetic rehabilitation of edentulous patients using suction denture

Kim YJ, Song YG

In patients with severely resorbed alveolar bone, it is difficult to gain retention in denture. Lack of retention makes denture unstable and lead to trouble in using denture. Suction denture...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study

Arat Bilhan S, Geckili O, Cilingir A, Bozdag E, Bilhan H

OBJECTIVES: In mandibular edentulism, the treatment option with a two-interforaminal implant-retained bridge and a removable partial denture is rarely evaluated in literature. The aim of this in vitro study was...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Functional impression technique using temporary denture for rehabilitation of severely atrophic maxillary and mandibular ridges

Suh YK, Bae JY, Kim HH

Soft liner is used to functional impression technique when dental stone is immediately poured after taking impression because of viscoelasticity. In this case, a 78-year-old male visited for new dentures....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Rehabilitation of fully edentulous patient using Ceramill full denture system (FDS)

Lee Y, Kwon KR, Pae A, Noh K, Paek J, Hong SJ

CAD/CAM technology has already been used in most areas of prosthetics. The range of CAD/CAM application in denture fabricating process has been gradually increasing since the CAD/CAM technology was introduced...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

Lee S, Hong SJ, Paek J, Pae A, Kwon KR, Noh K

PURPOSE: The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS: The maxillary edentulous master cast was fabricated and round shaped...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Physical properties and color stability of injection-molded thermoplastic denture base resins

Song SY, Kim KS, Lee JY, Shin SW

PURPOSE: The purpose of this study was to compare mechanical and physical properties of injection-molded thermoplastic denture base resins. MATERIALS AND METHODS: In this study, six commercially available products (VA; Valplast,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prosthetic treatment for Down's syndrome patient with dental cross bite problem using maxillary double crown denture

Doh SJ, Cho JH

Patients with Down's syndrome have several dental complications such as small teeth caused by underdevelopment of dentin and enamel, periodontitis, agenesis of teeth, prolonged retention of primary teeth and malocclusion...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prosthetic treatment for patient with congenital bilateral cleft lip and palate to close oro-nasal communication using maxillary double crown and clasp retained removable denture

Doh SJ, Cho JH

Patients with cleft lip and palate have several problems such as oro-nasal communication, dental cross-bite caused by the insufficient growth of maxilla, poor pronunciation and esthetic problem. Removable denture with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Complete denture artificial teeth arrangement deformation in wax denture after festooning: deformation over time

Lee SH, Kwak YH, Kim HJ

PURPOSE: The purpose of this study was to evaluate the deformation of the complete denture artificial teeth arrangement after festooning over time. MATERIALS AND METHODS: 10 wax dentures of equal teeth...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Causes of failures of long-term used double crown denture and new rehabilitation with dental implant and tooth combined denture using remaining teeth and implants

Seo JG, Cho JH

Hybrid telescopic double crown have ever been good treatment option for patient with periodontally unfavorable few remaining teeth for successful prognosis. Tooth and implant combined telescopic double crown can be...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Literature review and case report of prosthetic rehabilitation with telescopic denture

Sung HG, Jo EH, Ko KH, Huh YH, Park CJ, Cho LR

Telescopic denture has advantages such as transfer the occlusal force to the long axis of the abutment, easiness of oral hygiene management, increase of retention and stability, splint effect due...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Denture wearers' recognition for their oral health status, denture cleansing methods, and insurance health system

Kim S, Kim SK, Noh K, Ahn SJ, Baik SH, Kim JH, Yoo DK, Kim KR, Kwon KR

PURPOSE: The aim of the present investigation was to understand the incidence, prevalence of denture stomatitis in denture wearers, who were over 60 years old, and use the results for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effects of relining materials on the flexural strength of relined thermoplastic denture base resins

Sun Y, Song SY, Lee KS, Park JH, Ryu JJ, Lee JY

PURPOSE: The aim of this study was to evaluate the effects of relining materials on the flexural strength of relined thermoplastic denture base resins (TDBRs). MATERIALS AND METHODS: For shear bond...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Migrating foreign body in an adult bronchus: An aspirated denture

Panigrahi , Sahay N, Samaddar D, Chatterjee A

As a safety measure, dentures are routinely removed before surgery. Aspiration of a denture could be catastrophic, with medicolegal implications. Foreign body aspiration is uncommon in adults; however, aspirations may...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A case of removable dentures using digital method

Lee JS, Ahn SJ, Leesungbok R, Lee SW

Generally dentures are manufactured by conventional method, however the frequency of fabricating denture using digital method is increasing due to the recent development of digital technology in dentistry. The digital...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Nonthermal plasma on the shear bond strength of relining resin to thermoplastic denture base resin

Manaloto-Ceballos L, Labriaga W, Song SY, Park JH, Lee JY, Shin SW

PURPOSE: This study evaluated the effect of nonthermal plasma treatment on the bond strength of autopolymerizing relining resin to the injection molded thermoplastic denture base resins (TDBRs) with different surface...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2023 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr