Korean J Intern Med.  2021 Sep;36(5):1204-1210. 10.3904/kjim.2020.643.

Evaluation of copper alloys for reducing infection by methicillin resistant Staphylococcus aureus and vancomycin resistant Enterococcus faecium in intensive care unit and in vitro

Affiliations
  • 1Department of Internal Medicine, Dongguk University Ilsan Hospital, Goyang, Korea
  • 2Department of Pathology, Seoul National University Boramae Hospital, Seoul National University College of Medicine, Seoul, Korea
  • 3Department of Infectious Diseases, Uijeongbu Eulji Medical Center, Eulji University, Uijeongbu, Korea
  • 4Department of Infectious Diseases, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
  • 5Department of Internal Medicine, Seoul St. Mary’s Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea

Abstract

Background/Aims
Multi-drug resistant pathogens are increasing among healthcare-associated infections. It is well known that copper and copper alloys have antimicrobial activity. We evaluated the activity of copper against bacteria in a hospital setting in Korea.
Methods
This study was conducted in a laboratory and medical intensive care unit (ICU). Methicillin resistant Staphylococcus aureus (MRSA) and vancomycin resistant Enterococcus faecium (VRE) were inoculated onto copper, copper alloy and stainless steel plates. After 24 hours of incubation, colony-forming units (CFU) were counted in the laboratory. Two similar rooms were chosen in the ICU; one room had copper-containing surface, and the other room contained items with a stainless steel surfaces. Items were sampled weekly for 8 weeks when the rooms were not crowded and when the rooms were busier with healthcare workers or visitors.
Results
In vitro time-kill curves showed copper or, a copper alloy yielded a significant reduction in MRSA and VRE CFUs over 15 minutes. Upon exposure to stainless steel plates, CFUs were slowly reduced for 24 hours. In vivo, MRSA CFUs were lower in rooms with copper-containing surfaces compared with controls, both after cleaning and after patients had received visitors (p < 0.05). Analysis of VRE revealed similar results, but VRE CFUs from copper-containing surfaces of drug carts in the ICU did not decrease significantly.
Conclusions
Copper has antimicrobial activity and appears to reduce the number of multi-drug resistant microorganisms in a hospital environment. This finding suggests the potential of the use of copper fittings, instruments and surfaces in hospital.

Keyword

Copper; Antibacterial activity; Methicillin-resistant Staphylococcus aureus; Vancomycin resistant Enterococcus faecium; Intensive care units
Full Text Links
  • KJIM
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr