Int J Arrhythm.  2020 Sep;21(3):e14. 10.1186/s42444-020-00022-8.

Relationship between right ventricular pacing and non-sustained ventricular arrhythmias in patients with dual-chamber pacemaker and normal range left ventricular ejection fraction

Affiliations
  • 1Department of Internal Medicine, OhioHealth Doctors Hospital, 5100 West Broad Street, Columbus, OH 43228, USA
  • 2Section of Cardiac Electrophysiol‑ ogy, Department of Cardiology, OhioHealth Heart and Vascular Physicians, Riverside Methodist Hospital, 3535 Olentangy River Road, Columbus, OH 43214, USA

Abstract

Background
Right ventricular pacing (RVP) increases heart failure, AF, and death rates in pacemaker patients and ventricular arrhythmias (VAs) in defibrillator patients. However, the impact of RVP on VAs burden and its clinical significance in pacemaker patients with normal range LVEF of > 50–55% remains unknown. We sought to evaluate the relationship of RVP and VAs and its clinical impact in a pacemaker patient population.
Methods
Records of 105 patients who underwent de novo dual-chamber pacemaker implant or a generator change (Medtronic™ or Boston Scientific™) for AV block and sinus node disease at a tertiary care center between September 1, 2015, and September 1, 2016, were retrospectively reviewed.
Results
Data from 105 patients (51% females, mean age 76 ± 1 years, mean LVEF 61 ± 0.7%) without history of VAs (98.2%) were reviewed over 1044 ± 23 days. Dependent patients (100% RVP) exhibited the lowest VAs burden when compared to < 100% RVP (isolated PVCs, PVC runs of < 4 beats, and NSVT; p ≤ 0.001). Patients with < 1% RVP also exhibited low VA burden with intermediate RVP (1–99.9%) being most arrhythmogenic for PVC runs (p = 0.04) and for isolated PVCs (p = 0.006). Antiarrhythmics/beta and calcium channel blockers use and stress tests performed to evaluate VAs which were positive requiring intervention did not differ significantly. Burden of > 1/h of PVC runs and increasing PVC runs/h were significantly associated with hospitalization (p = 0.04) and all-cause mortality (p = 0.03), respectively.
Conclusions
In pacemaker patients with normal range LVEF (> 50–55%), 100% RVP is associated with the lowest burden of NSVT. Furthermore, patients with < 1% RVP also exhibit low VA burden; however, intermittent RVP seems to significantly correlate with non-sustained VAs.

Keyword

Right ventricular pacing; Non-sustained ventricular arrhythmias; Dual-chamber pacemaker; Premature ventricular complex
Full Text Links
  • IJA
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr