1. Kachelriess M, Kalender WA. EKG-correlated image reconstruction from subsecond spiral computed tomography scans of the heart. Med Phys. 1998. 25:2417–2431.
Article
2. Nieman K, Oudkerk M, Rensing BJ, van Ooijen P, Munne A, van Geuns RJ. Coronary angiography with multi-slice computed tomography. Lancet. 2001. 357:599–603.
Article
3. Schroeder S, Kopp AF, Ohnesorge B, Flohr T, Baumbach A, Claussen CD, et al. Accuracy and reliability of quantitative measurements in coronary arteries by multi-slice computed tomography. Experimental and initial clinical results. Clin Raiol. 2001. 56:466–474.
Article
4. Kopp AF, Schroeder S, Kuettner A, Baumbach A, Georg C, Claussen CD, et al. Non-invasive coronary angiography with high resolution multidetector-row computed tomography. Results in 102 patients. Eur Heart J. 2002. 23:1714–1725.
Article
5. Nieman K, Cademartiri F, Lemos PA, Raaijmakers R, Pattynama PM, de Reyter PJ. Reliable noninvasive coronary angiography with fast submilimeter multislice spiral computed tomography. Circulation. 2002. 106:2051–2054.
Article
6. Leber AW, Knez A, Becker C, Becker A, White C, Steinbeck G, et al. Noninvasive intravenous coronary angiography using electron beam tomography and multislice computed tomography. Heart. 2003. 89:633–639.
Article
7. Schroeder S, Kopp AF, Kuettner A, Burgstahler C, Herdeg C, Seipel L, et al. Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography : Experience in 94 patients. Clin Imaging. 2002. 26:106–111.
Article
8. Nieman K, Rensing BJ, van Geuns RJ, Vos J, Pattynama PM, de Feyter PJ, et al. Non-invasive coronary angiography with multislice spiral computed tomography : impact of heart rate. Heart. 2002. 88:470–474.
Article
9. Giesler T, Baum U, Ropers D, Ulzheimer S, Wenkel E, Achenbach S, et al. Noninvasive visualization of coronary arteries using contrast-enhanced multidetector CT : influence of heart rate on image quality and stenosis detection. AJR. 2002. 179:911–916.
Article
10. Lembcke A, Rogalla P, Mews J, Blobel J, Enzweiler CN, Hamm B, et al. Imaging of the coronary arteries by means of multislice helical CT : optimization of image quality with multisegmental reconstruction and variable gantry rotation time. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 2003. 175:780–785.
11. Stierstorfer K, Flohr T, Bruder H. Segmented multiple plane reconstruction:a novel approximate reconstruction scheme for multi-slice spiral CT. Phys Med Biol. 2002. 47:2571–2581.
Article
12. Vembar M, Garcia MJ, Heuscher DJ, Matthews D, Bohme GE, Greenberg NL, et al. A dynamic approach to identifying desired physiological phases for cardiac imaging using multislice spiral CT. Med Phys. 2003. 30:1683–1693.
Article
13. Achenbach S, Ropers D, Holle J, Muschiol G, Daniel WG, Moshage W. In-plane coronary arterial motion velocity : measurement with electron-beam CT. Radiology. 2000. 216:457–463.
Article
14. Kopp AF, Schroeder S, Kuettner A, Heuschmid M, Georg C, Claussen CD, et al. Coronary arteries : retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window. Radiology. 2001. 221:683–688.
Article
15. Hong C, Becker CR, Huber A, Schoepf UJ, Ohnesorge B, Reiser MF, et al. ECG-gated reconstructed multi-detector row CT coronary angiography. Effect of varying trigger delay on image quality. Radiology. 2001. 220:712–717.
Article
16. Funabashi N, Kobayashi Y, Perlroth M, Rubin GD. Coronary artery : quantitative evaluation of normal diameter determined with electron-beam CT compared with cine coronary angiography-initial experience. Radiology. 2003. 226:263–271.
Article
17. Ropers D, Baum U, Pohle K, Anders K, Ulzheimer S, Achenbach S, et al. Detection of coronary artery stenosis with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation. 2003. 107:664–666.
Article
18. Maintz D, Juergens KU, Wichter T, Grude M, Heindel W, Fischbach . Imaging of coronary artery stents using multislice computed tomography : in vitro evaluation. Eur Raiol. 2003. 13:830–835.
Article
19. Kruger S, Mahnken AH, Sinha AM, Borghans A, Dedden K, Hanrath P, et al. Multislice spiral computed tomography for the detection of coronary stent restenosis and patency. Int J Cardiol. 2003. 89:167–172.
Article
20. Leber AW, Knez A, White CW, Becker A, von Ziegler F, Boekstegers P, et al. Composition of coronary atherosclerotic plaques in patients with acute myocardial infarction and stable angina pectoris determined by contrast-enhanced multislice computed tomography. Am J Cardiol. 2003. 91:714–718.
Article
21. Ning R, Tang X, Conover D, Yu R. Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit:preliminary phantom study. Med Phys. 2003. 30:1694–1705.
Article
22. Mahesh M. Next-generation x-ray CT units will provide <500 msec images with 3D resolution comparable to today's projection radiography. Med Phys. 2003. 30:1543–1544.