J Korean Radiol Soc.  1998 Jan;38(1):137-140. 10.3348/jkrs.1998.38.1.137.

Ultrasound-Guided Renal Biopsy with Automated Biopsy Gun Technique: Efficacy and Complications

Affiliations
  • 1Department of Diagnostic Radiology, Masan Samsung Hospital.

Abstract

PURPOSE: To evaluate the diagnostic yield and complications of percutaneous ultrasound-guided renal biopsyusing a biopsy gun in patients with diffuse renal disease.
MATERIALS AND METHODS
Using an automated biopsy gunmounted with a 16G needle, biopsies were performed on 90 patients with diffuse renal disease. In a total of 95biopsies, diagnostic yield, the mean number of glomeruli and frequency of complication were retrospectivelyanalysed.
RESULTS
Tissue adequate for histological diagnosis was obtained in 92% of procedures. Mean glomerularyield was 8.3, and complications were seen in 26% of the procedures, 25% of these were minor, and 1% were major.
CONCLUSION
For the diagnosis of diffuse renal disease, utrasound-guided percutaneous renal biopsy using anautomated biopsy gun is accurate and safe.

Keyword

Biopsies, technology; Kidney, biopsy; Ultrasound(US), guidance

MeSH Terms

Biopsy*
Diagnosis
Humans
Needles
Full Text Links