Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

700 results
Display

Development of an Automated Image Analyzer for Microvessel Density Measurement in Bone Marrow Biopsies

Chung Y, Shin S, Shim H, Sohn JY, Lee DE, Lee H, Eom HS, Kim KG, Kong SY

Angiogenesis is important for the proliferation and survival of multiple myeloma (MM) cells. Bone marrow (BM) microvessel density (MVD) is a useful marker of angiogenesis and an increase in MVD...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Guidelines for Transrectal Ultrasonography-Guided Prostate Biopsy: Korean Society of Urogenital Radiology Consensus Statement for Patient Preparation, Standard Technique, and Biopsy-Related Pain Management

Lee MS, Moon MH, Kim CK, Park SY, Choi MH, Jung SI, Korean Society of Urogenital Radiology (KSUR)

The Korean Society of Urogenital Radiology (KSUR) aimed to present a consensus statement for patient preparation, standard technique, and pain management in relation to transrectal ultrasound-guided prostate biopsy (TRUS-Bx) to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pathologic discrepancies between colposcopy-directed biopsy and loop electrosurgical excision procedure of the uterine cervix in women with cytologic high-grade squamous intraepithelial lesions

Kim SI, Kim SJ, Suh DH, Kim K, No JH, Kim YB

OBJECTIVE: To investigate pathologic discrepancies between colposcopy-directed biopsy (CDB) of the cervix and loop electrosurgical excision procedure (LEEP) in women with cytologic high-grade squamous intraepithelial lesions (HSILs). METHODS: We retrospectively identified...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Core-Needle Biopsy Does Not Show Superior Diagnostic Performance to Fine-Needle Aspiration for Diagnosing Thyroid Nodules

Shin I, Kim EK, Moon HJ, Yoon JH, Park VY, Lee SE, Lee HS, Kwak JY

PURPOSE: To compare the diagnostic performances of fine-needle aspiration (FNA) and core-needle biopsy (CNB) for thyroid nodules according to nodule size. MATERIALS AND METHODS: This retrospective study included 320 thyroid nodules...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Concordance of Three International Guidelines for Thyroid Nodules Classified by Ultrasonography and Diagnostic Performance of Biopsy Criteria

Yim Y, Na DG, Ha EJ, Baek JH, Sung JY, Kim JH, Moon WJ

OBJECTIVE: To investigate the concordance of three international guidelines: the Korean Thyroid Association/Korean Society of Thyroid Radiology, American Thyroid Association, and American College of Radiology for thyroid nodules classified by...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of prostate cancer detection rates of various prostate biopsy methods for patients with prostate-specific antigen levels of < 10.0 ng/mL in real-world practice

Oh KT, Koo KC, Chung BH, Lee KS

PURPOSE: Several strategies of prostate biopsy (PBx) have been introduced to improve prostate cancer (PCa) detection rates. However, studies comparing cancer detection rates (CDRs) according to biopsy methods in real-world...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Does the Time Interval from Biopsy to Radical Prostatectomy Affect the Postoperative Oncologic Outcomes in Korean Men?

Kim SJ, Ryu JH, Yang SO, Lee JK, Jung TY, Kim YB

BACKGROUND: Prostate cancer (PC) is the second most common type of cancer in men worldwide and the fifth most common cancer among Korean men. Although most PCs grow slowly, it...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Inflammation appears as high Prostate Imaging–Reporting and Data System scores on prostate magnetic resonance imaging (MRI) leading to false positive MRI fusion biopsy

Rourke E, Sunnapwar , Mais D, Kukkar V, DiGiovanni J, Kaushik D, Liss MA

PURPOSE: To investigate if inflammation as a potential cause of false-positive lesions from recent UroNav magnetic resonance imaging (MRI) fusion prostate biopsy patients. MATERIALS AND METHODS: We retrospectively identified 43 men...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnostic Accuracy of Percutaneous Transthoracic Needle Lung Biopsies: A Multicenter Study

Lee KH, Lim KY, Suh YJ, Hur J, Han DH, Kang MJ, Choo JY, Kim C, Kim JI, Yoon SH, Lee W, Park CM

OBJECTIVE: To measure the diagnostic accuracy of percutaneous transthoracic needle lung biopsies (PTNBs) on the basis of the intention-to-diagnose principle and identify risk factors for diagnostic failure of PTNBs in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Imaging-Guided Biopsy, Percutaneous Ablation, and Active Surveillance for Small Renal Masses

Kim SH, Park KJ, Kim MH, Kim JK

The diagnosis rates of small renal masses less than 4 cm in diameter are increasing with the increasing number of CT and MRI examinations. Since these small renal masses include...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Endoscopic Ultrasound Biopsy Needles for Endoscopic Ultrasound-Guided Liver Biopsy

Eskandari , Koo P, Bang H, Gui D, Urayama S

BACKGROUND/AIMS: To compare the performance of latest commercially available endoscopic ultrasound biopsy needles. METHODS: Six latest commercially available needles were tested on a freshly harvested bovine liver; the tested needles included...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Endoscopic Ultrasound-Guided Liver Biopsy Using a Core Needle for Hepatic Solid Mass

Chon HK, Yang HC, Choi KH, Kim TH

BACKGROUND/AIMS: This study aimed to evaluate the feasibility and efficacy of endoscopic ultrasound-guided fine needle biopsy (EUS-FNB) using a core needle for hepatic solid masses (HSMs). Additionally, the study aimed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Endoscopic Ultrasound-Guided Fine Needle Aspiration and Biopsy in Gastrointestinal Subepithelial Tumors

Pih GY, Kim DH

The incidence of asymptomatic and incidentally found upper gastrointestinal subepithelial tumors (SETs) is increasing with the implementation of national cancer screening and the development of high-resolution endoscopy in Korea. However,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Endoscopic Ultrasound-Guided Liver Biopsies: Is the Future Here Yet?

El Hajj II, Al-Haddad

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Retrospective Study of the Significant Predictive Role of Inflammatory Degree in Initial and Repeat Prostate Biopsy Specimens for Detecting Prostate Cancer

Kim SH, Park B, Joung JY, Chung J, Seo HK, Lee KH, Park WS

PURPOSE: The purpose of this study was to determine whether histologic inflammation (HI) in initial and repeat prostate biopsy specimens was significantly associated with the detection of prostate cancer. MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of outcomes of free-hand 2-dimensional ultrasound-guided versus navigated 3-dimensional ultrasound-guided biopsy for supratentorial tumours: a single-institution experience with 125 cases

Patil AD, Singh V, Sukumar V, Shetty PM, Moiyadi AV

PURPOSE: The purpose of this study was to evaluate the relative utility and benefits of free-hand 2-dimensional intraoperative ultrasound (FUS) and navigated 3-dimensional intraoperative ultrasound (NUS) as ultrasound-guided biopsy (USGB)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Same-Day versus Overnight Observation after Outpatient Pediatric Percutaneous Liver Biopsy: A Retrospective Cohort Study

Kozlovich , Sochet AA, Son S, Wilsey MJ

PURPOSE: Percutaneous liver biopsy (PLB), a diagnostic procedure to identify several hepatobiliary disorders, is considered safe with low incidence of associated complications. While postoperative monitoring guidelines are suggested for adults,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Tissue Transglutaminase Antibody and Its Association with Duodenal Biopsy in Diagnosis of Pediatric Celiac Disease

Meena DK, Akunuri S, Meena P, Bhramer A, Sharma SD, Gupta R

PURPOSE: This study aimed to evaluate a possible association between the anti-tissue transglutaminase antibody (anti-tTG) titer and stage of duodenal mucosal damage and assess a possible cut-off value of anti-tTG...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative study of indocyanine green combined with blue dye with methylene blue only and carbon nanoparticles only for sentinel lymph node biopsy in breast cancer

Qin X, Yang M, Zheng X

PURPOSE: The combination of indocyanine green and methylene blue (ICG + MB) was reported to be an efficient tracer method in sentinel lymph node biopsy (SLNB). However, whether this method...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Utility of Radial Probe Endobronchial Ultrasound-Guided Transbronchial Lung Biopsy in Diffuse Lung Lesions

Kim EJ, Kim KC

BACKGROUND: Radial probe endobronchial ultrasound (R-EBUS) is widely used for diagnosing peripheral pulmonary lesions. However, the utility of R-EBUS-guided transbronchial lung biopsy (TBLB) for diffuse lung lesions (DLLs) remains unknown....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2021 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr