Korean J Thorac Cardiovasc Surg.  2003 May;36(5):335-342.

The Clinical Experience of the Aortic Arch Replacement in Acute Type A Aortic Dissection

Affiliations
  • 1Department of Thoracic & Cardiovascular Surgery, College of Medicine, Dong-A University, Korea. gjcho@mail.donga.ac.kr

Abstract

BACKGROUND: The aortic arch replacement in an acute aortic dissection is technically demanding procedure that has a lot of postoperative morbidity and high mortality. The authors have applied several techniques of aortic arch replacement to overcome the risks of the procedure. Therefore we analysed the results of these techniques. MATERIAL AND METHOD: From March of 1996 to July of 2002, we performed 31 cases of the aortic arch replacement in the Stanford type A acute aortic dissection. There were 12 male and 19 female patients with 59.6+/-9.4 years of mean age. Among them 18 cases were treated with the hemiarch replacement and 13 cases with the total arch replacement. We approached the aortic arch through median sternotomy in all but 3 cases of Clamshell incision and applied the deep hypothermic circulatory arrest with retrograde cerebral perfusion. The associated procedures were 2 Bentall's procedures, an axillobifemoral bypass, a femorofemoral bypass and a carotid artery bypass. RESULT: The postoperative morbidities were 8 acute renal failures, 3 CNS complications, 2 low cardiac output syndromes, 2 malperfusion syndromes, and 2 deep wound infections. There were 4 cases of early hospital mortality which were from an acute renal failure, a postoperative bleeding, a low cardiac output syndrome, and a reperfusion syndrome. There were 3 cases of late hospital mortality which were from an acute renal failure, and 2 multiorgan failures. So the total mortality rate was 22.5%. There were 4 cases of late mortality after the discharge, which were form 2 cases of distal anastomotic rupture and 2 cases of intracranial hemorrhage.
CONCLUSION
The hemiarch replacement has relatively shorter operative time and lower hospital mortality but higher late mortality than the total arch replacement. The total arch replacement needs more technically demanding procedure.

Keyword

Aortic, arch; Aortic aneurysm, dissecting; Aortic aneurysm, arch

MeSH Terms

Acute Kidney Injury
Aorta, Thoracic*
Cardiac Output, Low
Carotid Arteries
Circulatory Arrest, Deep Hypothermia Induced
Female
Hemorrhage
Hospital Mortality
Humans
Intracranial Hemorrhages
Male
Mortality
Operative Time
Perfusion
Reperfusion
Rupture
Sternotomy
Wound Infection
Full Text Links
  • KJTCS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr