1). Brantigan JW, Steffe AD, Geiger JM. A carbon fiber implant to aid interbody lumbar fusion. Mechanical test ing. Spine. 1991; 16(6 Suppl):S277–82.
2). Ma GW. Posterior lumbar interbody fusion with special -ized instruments. Clin Orthip. 1985; 193:57–63.
3). Takeda M. Experience in posterior lumbar interbody fusion: Unicortical versus bicortical autologus grafts. Clin Orthop. 1985; 193:120–6.
4). Enker P Steffee AD. Interbody fusion and instrumentation. Clin Orthop. 1994; 300:90–101.
5). Lin PM. Posterior lumbar interbody fusion technique: Complications and fitfalls. Clin Orthop. 193:90–102. 1985.
6). Wetzel FT, LaRocca H. The failed posterior lumbar interbody fusion. Spine. 1991; 16:839–45.
Article
7). Verlooy J, De Smedt K, Selosse P. Failure of a modified posterior lumbar interbody fusion technique to produce adequate pain relief in isthmic spondylolytic grade 1 spondylolisthesis patients. Spine. 1993; 18:1491–5.
Article
8). Wimmer C, Krismer M, Gluch H, Ogon M, Stockl B. Autogenic versus allogenic bone grafts in anterior lumbar interbody fusion. Clin Orthop. 1999; 360:122–6.
Article
9). Simmon JW. Posterior lumbar interbody fusion with posterior elements as chip graft. Clin Orthop. 1985; 193:85–89.
10). Pitzen T, Geisler FH, Matthis D, Muller-Storz H, Steudel WI. Motion of threaded cages in posterior lumbar interbody fusion. Eur Spine J. 2000; 9:571–6.
Article
11). Gorlich Y, Lebek S, Reichel H. Substitution of tibial bony defects with allogeneic and autogeneic cancellous bone: Encouraging preliminary results in 18 knee replace -ments. Arch Orthop Trauma Surg. 1999; 119:220–2.
12). Leopold SS, Jacobs JJ, Rosenberg AG. Cancellous allograft in revision total hip arthroplasty. A clinical review. Clin Orthop. 2000; 371:86–97.
13). Bendo JA, Spivak JM, Neuwirth MG, Chung P. Use of the anterior interbody fresh-frozen femoral head allograft in circumferential lumbar fusions. J Spinal Disord. 2000; 13:144–9.
Article
14). Liljenqvist U, O’ Brien JP, Renton P. Simultaneous combined anterior and posterior lumbar fusion with femoral cortical allograft. Eur Spine J. 1998; 7:125–31.
Article
15). Wang JS, Tagil M, Aspenberg P. Load-bearing increases new bone formation in impacted and morselized allografts. Clin Orthop. 2000; 378:274–81.
Article
16). Kozak JA, Heilman AE, O’ Brien JP. Anterior lumbar fusion options. Technique and graft materials. Clin Orthop. 1994; 300:45–51.
Article
17). Rothman SL, Glenn MW Jr. CT evaluation of interbody fusion. Clin Orthop. 1985; 193:47–56.
Article
18). Tullberg T, Brandt B, Rydberg J, Fritzell P. F usi on rate after posterior lumbar interbody fusion with carbon fiber implant: 1-year followup of 51 patients. Eur Spine J. 1996; 5:178–82.
19). Bauer TW, Muschler GF. Bone graft materials. An overview of the basic science. Clin Orthop. 2000; 371:10–27.
20). Friedlaender GE. Bone grafts. The basic science ratio -nale for clinical applications. J Bone Joint Surg Am. 1987; 69:786–90.
21). Goldberg VM, Stevenson S. Natural history of autografts and allografts. Clin Orthop. 1987; 225:7–16.
Article