Korean J Thorac Cardiovasc Surg.  2008 Apr;41(2):239-246.

Percutaneous Endovascular Stent-graft Treatment for Aortic Disease in High Risk Patients: The Early and Mid-term Results

Affiliations
  • 1Department of Thoracic and Cardiovascular Surgery, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Korea. mluemoon@snubh.org
  • 2Department of Radiology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Korea.

Abstract

BACKGROUND: Aortic surgery for high risk patients has high mortality and morbidity rates, and the necessity of performing aortic surgery in cancer patients is questionable because of their short life expectancy. Endovascular repair of aneurysm repair can be considered for high risk patients and cancer patients because it has relatively lower invasiveness and shorter recovery times than aortic surgery does. Especially, percutaneous endovascular stent graft treatment is more useful for high risk patients because it does not require general anesthesia. MATERIAL AND METHOD: From July 2003 to September 2007, twelve patients who had inoperable malignancy or who had a high risk of complication because of their combined diseases during aortic surgery underwent endovascular aortic aneurysm repair. The indications for endovascular repair were abdominal aortic aneurysm in 5 patients, descending thoracic aortic aneurysm in 6 patients and acute type B aortic dissection in one patient. The underlying combined disease of these patients were malignancy in 3 patients, respiratory disease in 6 patients, old age with neurologic disease in 6 patients, Behcet's diseae in one patient and chronic renal failure in one patient. RESULT: Stent grafts were inserted percutaneously in all cases. There were 4 hospital deaths and there were 3 delayed deaths during the follow-up periods. There were no deaths from aortic disease, except one hospital death. There were several complications: a mild cerebrovascular accident occurred in one patient, acute renal failure occurred in 2 patients and ischemic bowel necrosis occurred in one patient. Mild type I endoleak was observed in 2 patients and type II endoleak was observed in a patient after stent graft implantation. Newly developed type I endoleak was observed in a patient during the follow-up period.
CONCLUSION
Percutaneous endovascular stent graft insertion is relatively safe procedure for high risk patients and cancer patients. Yet it seems that its indications and its long term results need to be further researched.

Keyword

Aneurysm; Stents; Aorta, abdominal; Aorta, thoracic

MeSH Terms

Acute Kidney Injury
Anesthesia, General
Aneurysm
Aorta, Abdominal
Aorta, Thoracic
Aortic Aneurysm
Aortic Aneurysm, Abdominal
Aortic Aneurysm, Thoracic
Aortic Diseases
Endoleak
Follow-Up Studies
Humans
Kidney Failure, Chronic
Life Expectancy
Necrosis
Stents
Stroke
Transplants
Full Text Links
  • KJTCS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr