Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

PUBLICATION DATE

18 results
Display

Analysis of Couch Sag Using Image Processing of MVCT Images in Tomotherapy

Park HR, Kim YH, Park D, Kim W, Ki Y, Kim D, Bae JS

In Tomotherapy the couch sags during the treatment due to the weight of the patient. In this study, we developed a simple method to obtain the amount of the sag...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Structure of an Oncology Information System Based on a Cost-Effective Relational Database for Small Departments of Radiation Oncology

Jeon H, Kim DW, Joo JH, Ki Y, Kim W, Park D, Nam J, Kim DH

Purpose: Radiation oncology information systems (ROIS) have evolved toward connecting and integrating information between radiation treatment procedures. ROIS can play an important role in utilizing modern radiotherapy techniques that have...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Anesthetic considerations for a patient with situs inversus totalis undergoing cardiac surgery: A case report

Koo CH, Shim JK, Kim N, Ki Y, Park J, Kim JC

A 58-year-old male patient with situs inversus totalis, a rare congenital malformation characterized by all asymmetric organs being formed as the mirror images of their normal morphologies, underwent mitral valve...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Prognostic value of the maximum standardized uptake value for the locoregional control in early glottic cancer

Kim D, Ki Y, Joo J, Jeon H, Park D, Nam J, Kim W

Purpose: To evaluate the prognostic value of the pretreatment maximum standardized uptake value (SUVmax) for locoregional control (LRC) of early glottic cancer treated with primary radiotherapy. Materials and Methods: We retrospectively...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of a Method to Measure the Radiation Isocenter Size of Linear Accelerators and Quantitative Analysis of the Radiation Isocenter Size for Clinac 21EX Linear Accelerator

Jeon H, Nam J, Park D, Kim YH, Kim W, Kim D, Ki Y, Kim D

  • KMID: 2243877
  • Korean J Med Phys.
  • 2011 Sep;22(3):131-139.
A method to get a size of the radiation isocenter of linear accelerators using star-shot images was presented and a computer program was developed to automate the method. Accuracy of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility of Improving the Accuracy of Dose Calculation Using Hybrid Computed Tomography Images: A Phantom Study

Jeon H, Kim DW, Joo JH, Ki Y, Kim W, Park D, Nam J, Kim DH

Purpose: Kilovoltage computed tomography (kV-CT) is essential for radiation treatment planning. However, kV-CT images are significantly distorted by artifacts when a metallic prosthesis is present in the patient's body. Thus, the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Minimization of Treatment Time Using Partial-Arc Volumetric Modulated Arc Therapy with Bladder Filling Protocol for Prostate Cancer

Lee H, Kim DW, Joo JH, Ki Y, Kim W, Park D, Nam J, Kim DH, Jeon H

Purpose: Radiotherapy after bladder filling protocol (BFP) is known to enhance treatment quality and reduce side effects in prostate cancer, a common male solid cancer globally. However, due to the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Coenzyme Q10 on Radiation Nephropathy in Rats

Ki Y, Kim W, Kim YH, Kim D, Bae JS, Park D, Jeon H, Lee JH, Lee J, Nam J

The kidney is one of the most radiosensitive organs in the abdominal cavity and is the dose-limiting structure in cancer patients receiving abdominal or total body irradiation. In the present...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An Experimental Method for the Scatter Correction of MV Images Using Scatter to Primary Ratios (SPRs)

Jeon H, Park D, Lee J, Nam J, Kim W, Ki Y, Kim D, Lee JH, Kim D

In general radiotherapy, mega-voltage (MV) x-ray images are widely used as the unique method to verify radio-therapeutic fields. But, the image quality of MV images is much lower than that...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Reading Deviations of Glass Rod Dosimeters Using Different Pre-processing Methods for Radiotherapeutic in-vivo Dosimetry

Jeon H, Nam J, Park D, Kim YH, Kim W, Kim D, Ki Y, Kim D, Lee JH

  • KMID: 2315750
  • Prog Med Phys.
  • 2013 Jun;24(2):92-98.
The experimental verification of treatment planning on the treatment spot is the ultimate method to assure quality of radiotherapy, so in-vivo skin dose measurement is the essential procedure to confirm...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility of Automated Detection of Inter-fractional Deviation in Patient Positioning Using Structural Similarity Index: Preliminary Results

Youn H, Jeon H, Lee J, Lee J, Nam J, Park D, Kim W, Ki Y, Kim D

The modern radiotherapy technique which delivers a large amount of dose to patients asks to confirm the positions of patients or tumors more accurately by using X-ray projection images of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Adaptive Image Rescaling for Weakly Contrast-Enhanced Lesions in Dedicated Breast CT: A Phantom Study

Kim B, Kim HK, Kim J, Ki Y, Joo JH, Jeon H, Park D, Kim W, Nam J, Kim DH

Purpose Dedicated breast CT is an emerging volumetric X-ray imaging modality for diagnosis that does not require any painful breast compression. To improve the detection rate of weakly enhanced lesions,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of Probiotics for Preventing Radiation-Induced Morphological Changes in Intestinal Mucosa of Rats

Ki Y, Kim W, Cho H, Ahn K, Choi Y, Kim D

Radiation therapy is an important treatment modality for abdominal or pelvic cancer, but there is a common and serious complication such as radiation-induced enteritis. Probiotics is reported to have positive...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparison of Anti-Pseudomonal effects by Multi-purpose Contact Lens Solutions

Kim J, Park HR, Cho Y, Ki Y, Hahn TW, Hahn YH, Tchah H

  • KMID: 2125408
  • J Korean Ophthalmol Soc.
  • 2002 Jan;43(1):178-188.
PURPOSE: To compare the antimicrobial effects of various kinds of multi-purpose solutions, study effective ways of washing contact lens (CLs), and suggest the most effective lens care system using P....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Treatment Planning System for AC Electric Field Therapy Based on Absorbed Energy

Oh G, Jo Y, Ki Y, Sung H, Yoon M

  • KMID: 2510048
  • Prog Med Phys.
  • 2020 Sep;31(S1):S19.
Purpose: Tumor Treating Electric Fields (TTF) therapy is cancer therapy that passed FDA in the United States. However, TTF therapy doesn’t have the concept of dose commonly used in radiotherapy...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Impact of diastolic dysfunction in patients with preserved ejection fraction undergoing permanent cardiac pacemaker placement

Jeong H, Kim H, Kim S, Kim H, Ki Y, Choi D, Park K, Lee K, Yoon N, Park H, Cho J

Background: Chronic right-ventricular (RV) pacing can exacerbate heart failure in patients with a low ejection fraction (EF). There is little information on the effects of diastolic dysfunction (DD) in patients...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Role of Post-Treatment 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography in Patients Receiving Definitive Chemoradiation for Locally Advanced Head and Neck Squamous Cell Carcinomas

Kim JJ, Oh SB, Jung KS, Park K, Kim SJ, Ki Y, Lee JC, Oh SY

Background and Objectives 18F-fluorodeoxyglucose PET/CT scans can be a useful method to detect recurrence. However, its role in locally advanced head and neck squamous cell carcinomas (HNSCCs) patients after definitive...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Adjuvant external beam radiation and brachytherapy for vaginal resection margin positive cervical cancer

Kim D, Ki Y, Kim W, Park D, Lee J, Lee J, Jeon H, Nam J

PURPOSE: To evaluate the treatment outcomes of adjuvant external beam radiation therapy (EBRT) and vaginal brachytherapy (VB) following radical hysterectomy in cervical cancer patients with involved vaginal resection margin (VRM). MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr