Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

171 results
Display

The Effect of Astigmatism Correction in Myopic Astigmatism by Toric Lenses: Comparison with Hard Contact Lenses

Lee JH, Yang SW

  • KMID: 2204921
  • J Korean Ophthalmol Soc.
  • 1988 Jun;29(3):373-375.
We compared the effects of astigmatism correction by toric lenses with that by hard contact lenses performing over-refraction in 14 eyes of 8 patients. The results are as following; 1)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pseudomonas Keratitis Due to Mishandling of Soft Contact lenses

Jeon SK, Tchah HW

  • KMID: 2123466
  • J Korean Ophthalmol Soc.
  • 1996 May;37(5):901-907.
Causative bacterias of keratitis due to mishandling of contact lenses are mainly Gram negative rods, and large percentage of them are Pseudomonas. We experienced 6 cases of culture-proven Pseudomonas keratitis...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Intraocular Pressure Difference With and Without Soft Contact Lenses by Noncontact Tonometry

Lee S, Kim M

  • KMID: 2336520
  • J Korean Ophthalmol Soc.
  • 1990 Apr;31(4):415-418.
Noncontact tonometer is a convenient instrument for checking of intraocular pressure without corneal touch. We compared the IOP of 45 eyes in 24 patients with and without soft contact lenses....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Presbyopia and contact lenses

Kim TJ

Presbyopia as a result of a gradual decrement in visual function at near is one of most prevalent conditions causing patient concern and complaints in the 40 years and older...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Observation on Soft Contact Lenses

Kim JM, Kim SM

  • KMID: 2204631
  • J Korean Ophthalmol Soc.
  • 1978 Mar;19(1):1-5.
Clinical observations were carried out in total 1,626 cases wearing fOft contact lenses made by International Contact Lens Lab. Seoul, Korea. The results of observation on 834 patients (1,626 eyes)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
+50 Method in Contact Lens Fitting

Choi DK

  • KMID: 2042473
  • J Korean Ophthalmol Soc.
  • 1974 Sep;15(3):201-204.
We fitted contact lenses in 216 eyes of 120 patients uniquely 0.50 D. steeper than the flattest meridian between January 1, 1971 and June 30, 1973. In this study all...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Keratitis with Elizabethkingia meningoseptica Occurring after Contact Lens Wear: A Case Report

Yang YS, Chun JW, Koh JW

To report keratitis with Elizabethkingia meningoseptica, which occurred in a healthy patient after wearing contact lenses for 6 months. A 24-year-old male patient visited our hospital with ocular pain. This...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Research on the Current Status of Contact Lenses in Korea

Choi TH, Kim HM, Cha HW, Kim JC, Kim MS, Lee HB, The Korean Contact Lens Study Society

  • KMID: 2337168
  • J Korean Ophthalmol Soc.
  • 2004 Nov;45(11):1833-1841.
PURPOSE: The purpose of this study is to present points of improvement data in developing a public educational approach for the correct understanding and use of contact lenses with a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Evaluation of Bausch and Lomb O3/O4 Soft Contact Lenses for Extended Wear

Youn DH, Rhee SW, Kim SM, Lee JH, Jung YC

  • KMID: 2336394
  • J Korean Ophthalmol Soc.
  • 1987 Apr;28(2):267-270.
The clinical evaluation of the "O3/O4" series of Bausch and Lomb company for extended wear were performed in 138 eyes of 69 patients. In 128 eyes(92.1%) of them the corrected...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Protease Activities in Various Kinds of Enzymatic Cleaners for Contact Lenses

Kim JH, Tanouchi H

  • KMID: 2336474
  • J Korean Ophthalmol Soc.
  • 1988 Feb;29(1):69-75.
UV-absorption method was able to determine protease activities in various kinds of enzymatic cleaners. Bioclen G and O2 had high protease activities at room temperature and were effective for artificial...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Results of Population-based Questionnaire on the Symptoms and Life styles Associated with Contact Lens

Dong EY, Kim EC, The Korean Contact Lens Study Society

  • KMID: 2336958
  • J Korean Ophthalmol Soc.
  • 2001 Jan;42(1):30-35.
The purpose of this study is to gather useful data in developing educational approach to the public about correct understanding and use of contact lenses by investigating public appreciation about...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Acanthamoeba Keratitis Related to Cosmetic Contact Lenses

Park YM, Hahn TW, Choi SH, Lee JS, Lee JE

  • KMID: 2021437
  • J Korean Ophthalmol Soc.
  • 2007 Jul;48(7):991-994.
PURPOSE: To report a rare case of Acanthamoeba keratitis in both eyes related to cosmetic contact lenses. METHODS: A 17-year-old girl with a history of wearing cosmetic contact lenses presented with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Experimental Studies on the Release of 17-Hydroxycorticosteroids from Soaked Soft Contact Lenses

Cho HW, Youn DH

  • KMID: 2122493
  • J Korean Ophthalmol Soc.
  • 1975 Dec;16(4):327-330.
The therapeutic application of the soft contact lenses are popular in ophthalmic use recently. Drug effects of greater magnitude and duration may be achieved by using a soft contact lens...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Study of Eye-Me(R) Soft Contact lens

Cho BJ, Wee WR, Lee JH

  • KMID: 2123256
  • J Korean Ophthalmol Soc.
  • 1993 Feb;34(2):91-97.
A clinical evaluation of Eye-Me(R) (Paik San, Korea), daily and extended wear, soft contact lenses was performed for a 3-month period. The two kinds of lenses were worn by 20...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Protease Activities in Various Kinds of Enzymatic Cleaneers for Contact Lenses

Kim JH, Tanouchi H

  • KMID: 2107482
  • J Korean Ophthalmol Soc.
  • 1987 Dec;28(6):1183-1189.
UV-absorption method was able to determine protease activities in various kinds of enzymatic cleaners. Bioclen G and O2 had high protease activeities at room temperature and were effective for artificial...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Permeability of Hydrophilic Contact Lenses

Ko MK

  • KMID: 1902454
  • J Korean Ophthalmol Soc.
  • 1977 Dec;18(4):343-346.
In this study, the oxygen permeabilities and diffusion rates of several soft contact lenses were measured and compared. The hydrophilic contact lenses used in this experiment were composed of four...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Fungal Keratitis as a Complication of Orthokeratology Contact Lens

Lee JK, Lee JE, Lee JS

PURPOSE: To present a case report of fungal keratitis related to prolonged overnight use of orthokeratology contact lenses. METHODS: A 13 year-old girl presented with a corneal ulcer in her left...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Nonsurgical correction of presbyopia

Na KS

This study aimed to describe the basic optical properties for presbyopia correction, including eyeglasses and contact lenses. Conventional eyeglasses are the most established technology for presbyopia correction, and contact lenses...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Changes of Corneal Sensitivity in Myopic Patients with Daily Wear Soft Contact Lenses According to Duration

Lee KH, Kim MS

  • KMID: 2122741
  • J Korean Ophthalmol Soc.
  • 1987 Aug;28(4):749-752.
Corneal sensitivity was measured with the Cachet-Bonnet aesthesiometer in control group of 24 people with 24 eyes and in 36 people with 56 eyes who had worn daily wear soft...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Alcaligenes xylosoxidans Keratitis in a Soft Contact Lens Wearer

Cho YK, Gi DH, Kim HK, La TY

PURPOSE: To report a case of corneal ulcer due to Alcaligenes xylosoxidans in a soft contact lens wearer. CASE SUMMARY: A 20-year-old female patient presented with a corneal ulcer. The patient...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr