Abstract

The effectiveness of TiN ion-plating was examined with TiN ion-plated Co-Cr wires(016", 016"X.022") on three different types of bracket(TiN ion-plated metal bracket, ceramic bracket and plastic bracket). Maximum static frictional forces and characteristic curves obtained from the frictional characteristic graph, were compared and surface roughness of wires and bracket slots before and after friction experiment was observed by SEM. The obtained results were as follows. · The frictional forces of TiN ion-plated wires were significantly lower than those of non ion-plated wires(P<0.O5 ).· On the effect of wire shape, the frictional forces of round wires were significantly lower than those of rectangular wires(P<0.05). · As the result of the SEM observation on the wires and bracket slots after the friction experiment, the surface of non ion-plated wires was rougher than that of TiN ion-plated ones. · The difference between the static frictional forces and the kinetic frictional forces was not significant in case of the TiN ion-plated round wires, but the static frictional forces were a little higher than the kinetic frictional forces in the TiN ion-plated rectangular wires. · The static frictional forces were much higher than the kinetic frictional forces in the case of non ion-plated wires.

Keyword

TiN ion-plating; Co-Cr orthodontic wire; frictional resistance

MeSH Terms

Ceramics
Friction*
Orthodontic Wires*
Plastics
Tin*
Ceramics
Plastics
Tin
Full Text Links
  • KJOD
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr