Measurement of Energy Parameters for Electron Gun Heater Currents and Output Dose Rate for Electron Beams from a Prototype Linac

Lim H, Lee M, Kim MY, Yi J, Lee M, Kang SK, Rhee DJ, Jeong DH

The dosimetric characteristics were experimentally evaluated for electron beams from the prototype linac developed for radiotherapy units. This paper focuses on the electron beam output and energy variations as a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Histological Characteristics of the Interface of Corneal Stroma and Descemet's Membrane

Jang JH, Park HJ, Ko MK

  • KMID: 2125575
  • J Korean Ophthalmol Soc.
  • 2003 Jul;44(7):1607-1612.
PURPOSE: This study was carried out to clarify the histological characteristics of the interface of the corneal stroma and Descemet's membrane of the human eye. METHODS: Nighteen donor eyes without...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on dose distribution of small irradiation field in the electron therapy

Kim SK, Shin SO, Kim MS

In electron therapy, low melting point alloy is used for shaping of the field. Electron field shaping material affect the output factor as well as the collimator system. The output...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Morpholgical Study of Korean Pubic Louse , Phthirus pubis ( Linnaeus , 1758 ) by Light and Scanning Electron Microscopy

Lee JS, Lee WK, Cho BK

  • KMID: 2231274
  • Korean J Dermatol.
  • 1990 Feb;28(1):26-33.
By light and scanning electron microscopy, the morphologies of Korean pubic louse(Phthirus pubis) were described and measured. Especially, electron microscopic structures of palpus, tuft organ, sensilla basiconicum and palpal lobe...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Recent advances in electron microscopy for the diagnosis and research of glomerular diseases

Honda K, Takaki T, Kang D

Recent technical advances in the detection of backscattered electrons during scanning electron microscopy (SEM) have improved resolution and have provided several new technologies for research and clinical practice in kidney...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Isolation and Identification of Melanosomes from Human Hair

Im SB, Lee SN, Hahn KW

Melanosomes were isolated from the human hair by graded centrifugation and identified by transmission and scanning electron microscopic examination. Melanosomes were separated from the keratinous structures by treating with strong...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Calculation of Energy Spectra for Electron Beam of Medical Linear Accelerator Using GEANT4

Joh YG, Kim HD, Kim BY, Kim SJ, Oh SA, Kang JK, Kim SK

  • KMID: 1451821
  • Korean J Med Phys.
  • 2011 Jun;22(2):85-91.
The energy spectra for electron beam of medical linear accelerator were calculated using a GEANT4 Medical Linac 2 example code. The incident electron mean energy were 6, 9, 12, 16,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Electron Energy Distribution for a Research Electron LINAC

Lim H, Lee M, Yi J, Kang SK, Kim MY, Jeong DH

The energy distribution was calculated for an electron beam from an electron linear accelerator developed for medical applications using computational methods. The depth dose data for monoenergetic electrons from 0.1...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Case of Woolly Hair

Lee SC, Yi JY, Kim SY, Cho BK, Song KY

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Localization of Keratinolytic Proteinase in Skin Tissue Sections of Guinea Pigs with Microsporum canis Infection by Immunoperoxidase Technique in Electron Microscopy

Lee KH, Park HW, Lee JB

An immunoperoxdase technique in electron microscopy was used to investigate the ultrastructural site of keratinolytic proteinase (KPase) of M crosporum cans in sections of skin from guinea pigs infected with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Syringocystadenoma Papilliferum: Unusual Location and Electron Microscopic Study

Hann SK, Choi YS, Choi EH

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study on the Effect of Field Shaping on Dose Distribution of Electron Beams

Kang WS, Cho MJ

  • KMID: 1657559
  • J Korean Soc Ther Radiol.
  • 1986 Dec;4(2):165-172.
In electron therapy, lead cutout or low-melting alloy block is used for shaping the field. Material for shaping electron field affects the output factor as well as the collimation system....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Variation of Effective SSD According to Electron Energies and Irradiated Field Sizes

Yang CY, Yum HY, Jung TS

  • KMID: 2097264
  • J Korean Soc Ther Radiol.
  • 1987 Dec;5(2):157-164.
It is known that fixed source to skin distance (SSD) cannot be used when the treatment field is sloped or larger than the size of second collimator in electron beam...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Electron Beam Dosimetries by Means of Several Kinds of Dosimeters

Kang WS

  • KMID: 2197254
  • J Korean Soc Ther Radiol.
  • 1989 Jun;7(1):93-100.
Several combinations of measuring devices and phantoms were studied to measure electron beams. Silicon PN junction diode was used to find the dependence of depth dose profile on field size...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Two Cases of Recurrent Herpes Zoster : Observation of the Herpes Virus by Electron Microscopy

Lee MG, Lee ES, Nam IW, Lee SN

  • KMID: 2231490
  • Korean J Dermatol.
  • 1987 Aug;25(4):520-524.
Herpes zoster is known to recur only rarely. However reports on the recurrence rates by various authors ranges from 0.l% to 8%. We have experienced 2 cases of recurrent herpes...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Freeze-fracture Scanning Electron Microscopy of the Human Retina

Lee SC, Kwon OW, Davidorf F

  • KMID: 1949589
  • J Korean Ophthalmol Soc.
  • 1991 Dec;32(12):1080-1085.
Our current understanding of the ultrastructure of the retina has been gained using transmis sion electron microscopy (TEM) of thin sections. Scanning electron microscopy was proven to be a very...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Three cases of epithelial skin cancer treated with high energy electron beam

You YH, Choi SB, Yi JY, Cho BK, Coi IB

  • KMID: 1693798
  • Korean J Dermatol.
  • 1993 Oct;31(5):829-934.
Higt energy electron beam therapy is a method which is used for the treatment of superficial tumors (less than 5 cm deep) with a characteristically sharp drop-off in dose beyond...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Scanning electron microscopic study of capillary change in bleomycin-induced pulmonary fibrosis

Kwon KY, Park KK, Chang ES

The architectural changes which occur in the capillaries are difficult to illustrate without a three-dimensional tool, such as scanning electron microscopy. Therefore, a scanning electron microscopic study was occasionally undertaken...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Reduction of Electron ContaminationUsing a Filter for 6MV Photon Beam

Lee CS, Yoo MJ, Yum HY

  • KMID: 2196513
  • J Korean Soc Ther Radiol.
  • 1997 Jun;15(2):159-166.
PURPOSE: Secondary electrons generated by interaction between primary X-ray beam and block tray in megavoltage irradiation, result in excess soft radiation dose to the surface layer. To reduce the surface...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Implementation and Evaluation of the Electron Arc Plan on a Commercial Treatment Planning System with a Pencil Beam Algorithm

Kang SK, Park S, Hwang T, Cheong KH, Lee MY, Kim KJ, Oh DH, Bae H

  • KMID: 1460197
  • Korean J Med Phys.
  • 2010 Sep;21(3):304-310.
Less execution of the electron arc treatment could in large part be attributed to the lack of an adequate planning system. Unlike most linear accelerators providing the electron arc mode,...
CITED
export Copy