Stent Graft Placement for Dysfunctional Arteriovenous Grafts

Jeon GS, Shin BS, Ohm JY, Ahn M

PURPOSE: This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. MATERIALS AND METHODS: Eleven patients who underwent stent graft placement for a dysfunctional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of a Nitinol Stent versus Balloon Angioplasty for Treatment of a Dysfunctional Arteriovenous Graft

Yoon YC, Shin BS, Ahn M, Park MH, Ohm JY, Kim HJ

PURPOSE: This study aimed to 1) evaluate the outcome of placing a nitinol stent for treating dysfunctional arteriovenous grafts (AVG), and 2) compare the results with those of successful balloon...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Usefulness of a Guiding Sheath for Fluoroscopic Colorectal Stent Placement

Song HY, Nam DH, Lee H

OBJECTIVE: To investigate the technical feasibility, clinical usefulness, and safety of a guiding sheath in fluoroscopic stent placement for patients with malignant colorectal obstructions. MATERIALS AND METHODS: Between June 2007 and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Risk Factors and Clinical Evaluation of Superficial Femoral Artery Stent Fracture: Protege GPS Stent

Lee D, Kim JK, Jung HD, Huh TW, Yim NY, Oh HJ, Chang NK, Choi SJ

  • KMID: 2344968
  • J Korean Soc Radiol.
  • 2010 Dec;63(6):513-518.
PURPOSE: To evaluate the occurrence of superficial femoral artery stent fractures, the risk factors of stent fracture, and the relationship between fractures and clinical findings. MATERIALS AND METHODS: Of the 38...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Endovascular Stent Placement for the Treatment of Superficial Femoral Artery Stenoses and Occlusions

Kim SK, Yang HS, Han JH, Chang NK, Yim NY, Yoon W, Kim JK

PURPOSE: The aim of this study was to evaluate effectiveness of an endovascular stent placement in the treatment of superficial femoral artery stenoses and occlusions. MATERIALS AND METHODS: An angioplasty and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnosis of Arteriovenous Fistulas following a Lumbar Discectomy

Roh BS, Choi MY, Jean SJ, Park SH, Kim HW, Kim JH

PURPOSE: To evaluate the relevant clinical and radiographical findings for the diagnosis of an arteriovenous fistula after a lumbar discectomy. MATERIALS AND METHODS: Five patients with an arteriovenous fistula following...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Noninvasive Assessment of In-Stent Restenosis of the Coronary Artery with Using 16-Slice Computed Tomography

Yoo E, Choi BW, Chung N, Seo JS, Kim YJ, Kim TH, Choe KO

PURPOSE: We strove to evaluate in-stent restenosis of the coronary artery by measuring the in-stent CT attenuation with using 16-multislice CT. MATERIALS AND METHODS: We analyzed the coronary CT angiography, with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Endovascular Stent-Graft Placement and Secondary Intervention for Abdominal Aortic Aneurysm in a Patient who had a Previously Inserted Iliac Stent

Jeon YS, Cho SG, Hong KC

Endovascular repair of abdominal aortic aneurysm is associated with low morbidity and mortality rates when compared to open surgery, and this can be used in patients who are at a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Primary Stent Placement for Chronic Spontaneous Infrarenal Abdominal Aortic Dissection: A Case Report

Kwon SH, Oh JH

Spontaneous infrarenal abdominal aortic dissection (SIAAD) is a rare entity with various clinical presentations. We recently encountered the even rarer condition of a female patient suffering from chronic SIAAD with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Efficacy of a Paclitaxel-Eluting Nitinol Stent on the Inhibition of Pseudointimal Hyperplasia in a Transjugular Intrahepatic Portosystemic Shunt: An Experimental Study in a Swine Model

Seo TS, Oh JH, Kwon SH, Park YK, Song HY, Yuk SH

PURPOSE: To evaluate the efficacy of a paclitaxel-eluting nitinol stent on the inhibition of pseudointimal hyperplasia in a transjugular intrahepatic portosystemic shunt. MATERIALS AND METHODS: Twelve pigs were used in this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Results of Carotid Artery Stenting using Filter Wire in 24 Consecutive Symptomatic Patients with Severe Stenosis

Choi HW, Lee TH, Kim HJ, Kim CW, Kim S, Choo KS, Lee SH

PURPOSE: The aims of this study were to analyze the results of carotid artery stenting using distal protection with FilterWire, and evaluate the effectiveness of FilterWire for distal embolic protection. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Interventional Management of Malignant Colorectal Obstruction: Use of Covered and Uncovered Stents

Choi JS, Choo SW, Park KB, Shin SW, Yoo SY, Kim JH, Do YS

Objective: We wanted to evaluate usefulness of uncovered stent in comparison with covered stent for the palliative treatment of malignant colorectal obstruction. Materials and Methods: Covered (n = 52, type...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
3D Multislice CT Angiography in Post-Aortic Stent Grafting: A Pictorial Essay

Sun Z

Helical CT angiography has been widely used in both pre- and post-aortic stent grafting and it has been confirmed to be the preferred modality when compared to conventional angiography. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Endovascular Therapy of Left Subclavian Artery Stenosis in Patients with Left Internal Mammary-Coronary Artery Bypass Graft

Jae HJ, Park JH, Shin CI, Lee BJ, Cho YK, Chung JW

PURPOSE: We wanted to evaluate the clinical usefulness of percutaneous transluminal angioplasty (PTA) and stenting of left subclavian artery (LSA) stenosis in the patients with a left internal mammary artery...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Spontaneous Rupture of the Left Common Iliac Vein: Management with Surgical Repair and Endovascular Stent

Kim YH, Lee SK, Ko SM, Choi JS, Koo JH, Kim HT, Cho WH

We report here on a case of spontaneous rupture of the left common iliac vein that was diagnosed preoperatively with computed tomography (CT), and the patient was successfully treated with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Metallic Stent Placement in Hemodialysis Graft Patients after Insufficient Balloon Dilation

Liang HL, Pan HB, Lin YH, Chen CY, Chung HM, Wu TH, Chou KJ, Lai PH, Yang CF

OBJECTIVE: We wanted to report our experience of metallic stent placement after insufficient balloon dilation in graft hemodialysis patients. MATERIALS AND METHODS: Twenty-three patients (13 loop grafts in the forearm...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Complications after Endovascular Treatment

Ko GY, Sung KB, Yoon HK

  • KMID: 1941010
  • J Korean Soc Vasc Surg.
  • 2006 May;22(1):60-68.
Endovascular treatment has rapidly progressed due to the improvements of the equipment and endovascular devices. Continual refinement of the technology and techniques associated with endovascular treatment has led interventionists to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Radioisotope Treatment for Benign Strictures of Non-vascular Luminal Organs

Shin JH

  • KMID: 2313020
  • Nucl Med Mol Imaging.
  • 2006 Apr;40(2):106-112.
Tissue hyperplasia is one of the most frequently encountered complications when self-expanding metallic stents are placed in benign non-vascular luminal organ strictures, thus causing restenosis of the lumen. The investigators...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An Experience with Placement of a Stent-Graft in a Renal Artery Aneurysm via the Brachial Artery: A Case Report

Park MH, Shin BS, Ahn M

We introduce here our case of a 4-cm, large saccular aneurysm in a patient with right flank pain that was treated by placement of a stent-graft via the left brachial...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Treatment of Malignant Gastroduodenal Obstruction with Using a Newly Designed Complex Expandable Nitinol Stent: Initial Experiences

Jung MH, Jung GS, Ko JH, Lee EJ, Oh KS, Huh JD, Cho YD, Park SJ

PURPOSE: We wanted to evaluate the usefulness of a new type of a complex expandable nitinol stent that was designed to reduce the stent's propensity to migration during the treatment...