Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

68 results
Display

Monte Carlo Simulation Codes for Nuclear Medicine Imaging

Chung YH, Beak CH, Lee SJ

  • KMID: 1484980
  • Nucl Med Mol Imaging.
  • 2008 Apr;42(2):127-136.
Monte Carlo simulation methods are especially useful in studying a variety of problems difficult to calculate by experimental or analytical approaches. Nowadays, they are extensively applied to simulate nuclear medicine...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Monte Carlo Simulation Study of a Therapeutic Proton Beam Delivery System Using the Geant4 Code

Shin J, Shim H, Kwak J, Kim D, Park S, Cho KH, Lee SB

  • KMID: 2243993
  • Korean J Med Phys.
  • 2007 Dec;18(4):226-232.
We studied a Monte Carlo simulation of the proton beam delivery system at the National Cancer Center (NCC) using the Geant4 Monte Carlo toolkit and tested its feasibility as a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A review of the Bayesian approach with the MCMC and the HMC as a competitor of classical likelihood statistics for pharmacometricians

Choi K

This article reviews the Bayesian inference with the Monte Carlo Markov Chain (MCMC) and the Hamiltonian Monte Carlo (HMC) samplers as a competitor of the classical likelihood statistical inference for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Monte Carlo Photon and Electron Dose Calculation Time Reduction Using Local Least Square Denoising Filters

Cheong KH, Suh TS, Cho BC, Jin H

  • KMID: 2080300
  • Korean J Med Phys.
  • 2005 Sep;16(3):138-147.
The Monte Carlo method cannot have been used for routine treatment planning because of heavy time consumption for the acceptable accuracy. Since calculation time is proportional to particle histories, we...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Energy Spectrum of KRISS 60Co Irradiation System

Yi CY, Chun KJ, Hah SH, Kim HM

  • KMID: 1482444
  • Korean J Med Phys.
  • 2008 Jun;19(2):139-141.
The photon energy spectrum of KRISS 60Co irradiation system (AECL Eldorado 8) was calculated by means of the Monte Carlo method. The collimators were modeled realistically, and the material and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative Study of Exposure Assessment of Dust in Building Materials Enterprises Using ART and Monte Carlo

Jiang W, Wu Z, Zhang M, Zhang H

Background Dust generated during the processing of building materials enterprises can pose a serious health risk. The study aimed to compare and analyze the results of ART and the Monte Carlo...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of DICOM Convert Program for the Geant4 Monte Carlo Simulation of the Radiotherapy

Kang J, Lee DJ

The DICOM converter program of the Geant4 Monte Carlo simulation code for the application of radiotherapy was developed. We analysis the header part of the DICOM file and find various...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields

Jeong DH, Lee JO, Kang JK, Kim SK, Kim SK, Moon SR

  • KMID: 1840643
  • J Korean Soc Ther Radiol Oncol.
  • 1998 Jun;16(2):195-202.
PURPOSE: In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dose Verification Study of Brachytherapy Plans Using Monte Carlo Methods and CT Images

Cheong KH, Lee MY, Kang SK, Bae H, Park S, Kim KJ, Hwang TJ, Oh DH

  • KMID: 1460191
  • Korean J Med Phys.
  • 2010 Sep;21(3):253-260.
Most brachytherapy treatment planning systems employ a dosimetry formalism based on the AAPM TG-43 report which does not appropriately consider tissue heterogeneity. In this study we aimed to set up...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Verification of the PMCEPT Monte Carlo dose Calculation Code for Simulations in Medical Physics

Kum O

  • KMID: 1482448
  • Korean J Med Phys.
  • 2008 Mar;19(1):21-34.
The parallel Monte Carlo electron and photon transport (PMCEPT) code [Kum and Lee, J. Korean Phys. Soc. 47, 716 (2006)] for calculating electron and photon beam doses has been developed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study on the 6 MV Photon Beam Characteristics and Analysis Method from Medical Linear Accelerators Using Geant4 Medical Linac2 Example

Kim BY, Kim HD, Kim SJ, Oh SA, Kang JG, Kim SK

  • KMID: 1451820
  • Korean J Med Phys.
  • 2011 Jun;22(2):79-84.
In this study, Geant4 based Monte Carlo simulations were carried out for medical linear accelerator. Modified Medical Linac2 toolkit was used for calculation. The energy spectrum, most probable energy and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development Treatment Planning System Based on Monte-Carlo Simulation for Boron Neutron Capture Therapy

Kim MS, Kubo K, Monzen H, Yoon DK, Shin HB, Kim S, Suh TS

The purpose of this study is to develop the treatment planning system (TPS) based on Monte-Carlo simulation for BNCT. In this paper, we will propose a method for dose estimation...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Validation of the finger counting method using the Monte Carlo simulation

Kang H, Cho Y, Lee J, Cha H, Lee H, Choi D, Cho GC, Lee D, Ahn JY, Sohn Y

PURPOSE: The dose of drug and the size of instrument are determined based on children's weight. We aimed to validate the finger counting method (FCM) for weight estimation in Korean...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Phantom Dose in a Rotating Total Skin Electron Irradiation (RTSEI) Using Monte Carlo Method and Optically Stimulated Luminescent Dosimeter (OSLD)

Shin JB, Kim C, Lee D, Yoon K, Park MJ, Goh Y, Kim Sw, Lee M, Hong SM, Noh S, Kang S, Cho B, Kwak J, Jeong C

  • KMID: 2510038
  • Prog Med Phys.
  • 2020 Sep;31(S1):S10.
Purpose: The purpose is to study the optimal Rotating total skin electron irradiation (RTSEI) treatment method through phantom dose evaluation using Monte Carlo method and optically stimulated luminescent dosimeter (OSLD). Methods:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Verification of Secondary Electron Generated by Head Screw in Gamma Knife Using Monte Carlo N-Particle Simulation

Kim H, Lee JW

Purpose: The interaction of various substances inserted into the human body and radiation can confirm the radiation enhancement effect. A Leksell frame inserted into the human body for gamma knife...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Methodological issues for determining intervals of subsequent cancer screening

Bae JM

The gap between nationwide recommendations of cancer screening and the related evidences obtained from Korean adults should be filled. Estimation of the mean sojourn time (MST) in a specific cancer...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of GATE Monte Carlo Code for Simulation and Dosimetry of New I-125 Seeds in Eye Plaque Brachytherapy

Taherparvar P, Fardi Z

Purpose Dose distributions are calculated by Monte Carlo (MC) simulations for two low-energy models 125 I brachytherapy source—IrSeed-125 and IsoAid Advantage (model IAI-125A)—loaded in the 14-mm standardized plaque of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of Monte Carlo Simulation Code for the Dose Calculation of the Stereotactic Radiosurgery

Kang J, Lee DJ

  • KMID: 2315736
  • Prog Med Phys.
  • 2012 Dec;23(4):303-308.
The Geant4 based Monte Carlo code for the application of stereotactic radiosurgery was developed. The probability density function and cumulative density function to determine the incident photon energy were calculated...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Monte Carlo Calculation on the Dose Modulation Using Dynamic Magnetic Fields for 10 MV X-rays

Kim KH, Oh YK, Shin KC, Kim JK, Jeong DH, Kim JK, Cho MJ, Kim SY

  • KMID: 2243992
  • Korean J Med Phys.
  • 2007 Dec;18(4):221-225.
Monte Carlo calculations were performed to demonstrate the dose modulation with dynamic magnetic fields in phantom. The goal of this study is to obtain the uniform dose distributions at a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation

Jung JY, Yoon DK, Suh TS

The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2026 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr