Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

662 results
Display

The comparison of initial retentive force in different double crown systems

Kwon HB, Roh YH, Lee SH

  • KMID: 2000647
  • J Korean Acad Prosthodont.
  • 2006 Dec;44(6):677-682.
STATEMENT OF PROBLEM: Various double crown systems have been used with removable partial dentures in the clinical field. Although retentive force between inner and outer crown are affected by several...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Technical complications of cement-retained implant-supported single crowns and splinted crowns with zirconia frameworks

You SC, Bae JY

PURPOSE: This study was to assess clinically the success rates and technical complications of cement-retained implant-supported single crowns and splinted crowns with zirconia frameworks. MATERIALS AND METHODS: 75 (single crowns: 51,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A STUDY ON FRACTURE STRENGTH OF CONVENTIONAL AND COPY-MILLED IN-CERAM CROWNS

Hwang JW, Yang JH, Lee SH, Chung HY

  • KMID: 2136387
  • J Korean Acad Prosthodont.
  • 1997 Jun;35(2):417-430.
The purpose of this study was to compare the fracture resistance of copy-milled and conventional In-Ceram crown. Four groups of ten uniform sized all-ceramic crowns were fabricated. In-Ceram Spinell and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Marginal fit of the digident CAD/CAM zirconia ceramic crowns

Kim YS, Yang JH

  • KMID: 2000679
  • J Korean Acad Prosthodont.
  • 2006 Jun;44(3):275-283.
Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. However most of the statistical inferences are not definite...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fracture strength of zirconia monolithic crowns and metal-ceramic crowns after cyclic loading and thermocycling

Lee SM, Jeong HC, Jeon YC

  • KMID: 2195693
  • J Korean Acad Prosthodont.
  • 2007 Feb;45(1):12-20.
PURPOSE: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness (0.5mm, 0.8mm, 1.1mm) and metal-ceramic crowns (1.0mm, 1.5mm). MATERIAL...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
In vitro marginal fit of the computer-aided milled cercon crowns

Chang JY, Yang JH, Han JS, Lee JB

  • KMID: 2000726
  • J Korean Acad Prosthodont.
  • 2005 Jun;43(3):306-313.
STATEMENT OF PROBLEM: There have been many studies about marginal discrepancy of single restorations made by various systems and materials. But most of statistical inferences are not definite because of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fracture strengths of ceromer crowns supported on the various abutment core materials

Kim YO, Ku CW, Park YJ, Yang HS

  • KMID: 2000768
  • J Korean Acad Prosthodont.
  • 2004 Dec;42(6):647-653.
STATEMENT OF PROBLEM: The effects of various core buildup materials which differs in the mechanical properties on the fracture strength of metal-free crowns is unknown. PURPOSE: This study was carried...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of the shades of background substructures on the overall color of zirconia-based all-ceramic crowns

Suputtamongkol K, Tulapornchai C, Mamani J, Kamchatphai W, Thongpun N

PURPOSE: The objective of this study was to determine the effect of the color of a background substructure on the overall color of a zirconia-based all-ceramic crown. MATERIALS AND METHODS: Twenty...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Marginal accuracy and fracture strength of Targis/Vectris Crowns prepared with different preparation designs

Song HY, Cho LR

  • KMID: 2195932
  • J Korean Acad Prosthodont.
  • 2000 Dec;38(6):791-799.
STATEMENT OF PROBLEM: Targis/Vectris restorations provide excellent esthetics. Marginal accuracy is significantly influenced by the preparation design. There were no studies to examine the effect of preparation design on the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative fracture strength analysis of Lava and Digident CAD/CAM zirconia ceramic crowns

Kwon TK, Pak HS, Yang JH, Han JS, Lee JB, Kim SH, Yeo IS

PURPOSE: All-ceramic crowns are subject to fracture during function. To minimize this common clinical complication, zirconium oxide has been used as the framework for all-ceramic crowns. The aim of this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A 2-year clinical evaluation of Sculpture crowns

Ku CW, Yang HS

  • KMID: 2195934
  • J Korean Acad Prosthodont.
  • 2000 Dec;38(6):806-813.
STATEMENT OF PROBLEMS: There are only a few studies available that deal with the clinical behavior of ceromer systems as potential substitutes for metal-ceramic crowns. PURPOSE: This prospective study was initiated...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Morphometric Study of Primary Anterior Zirconia Crowns in Korean Tooth Models

Park J, Lee S, Lee N, Jih M

The purpose of this study was to provide clinical recommendations for restoration with selection of the most similar zirconia crown by 3-dimensional analysis of the shape of the maxillary primary...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Colorimetric Analysis of Preformed Zirconia Anterior Crowns for Esthetic Restoration

Lee C, Park K, Yang Y, Lee D, Kim J

The purpose of this study was to identify which combination of zirconia crowns and cements is most similar in color to the maxillary primary incisors by varying the color of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of fracture strength between hybrid-ceramic crown and metal-ceramic crown

Ku CW, Yang HS

  • KMID: 2195903
  • J Korean Acad Prosthodont.
  • 2001 Feb;39(1):14-24.
The purpose of this study was to compare the fracture strengths and the fracture patterns of several hybrid-ceramic crowns and metal-ceramic crown. Ten crowns were constructed for each group according...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study of the shear bond strength of metal brackets and ceramic brackets and the condition after debonding

Yoon JJ, Ryu YK

  • KMID: 2271203
  • Korean J Orthod.
  • 1992 Jun;22(2):327-343.
Metal brackets and ceramic brackets were bonded to natural teeth, porcelain crowns and gold crowns. After stored in artificial saliva solution for 72 hours at 37degreesC, the shear bond strengths...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fracture strength of zirconia ceramic crowns according to tooth position

Lee IS, Kim JM, Dong JK

  • KMID: 2321770
  • J Korean Acad Prosthodont.
  • 2010 Apr;48(2):94-100.
PURPOSE: The purpose of this study was to compare the fracture strength of the zirconia ceramic crowns according to tooth position. MATERIAL AND METHODS: After 10 metal dies were made for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparison of the fidelity of various zirconia-based all-ceramic crowns fabricated with CAD/CAM systems

Kim SJ, Jo KH, Lee KB

STATEMENT OF PROBLEM: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems there is a need...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
FRACTURE STRENGTH OF THE IPS EMPRESS CROWN:THE EFFECT OF OCCLUSAL DEPTH AND AXIAL INCLINATION ON UPPER FIRST PREMOLAR CROWNS

Dong JK, Oh SC, Kim SD

  • KMID: 2321663
  • J Korean Acad Prosthodont.
  • 1999 Feb;37(1):127-133.
The purpose of this study was to compare the fracture strength of the IPS Empress ceramic crown according to the occlusal depth (1.5mm, 2.0mm, 2.5mm) and axial inclination (4degree, 8degree,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques

Yun MJ, Jeon YC, Jeong CM, Huh JB

PURPOSE: The purpose of this study was to compare the fit of cast gold crowns fabricated from the conventional and the digital impression technique. MATERIALS AND METHODS: Artificial tooth in a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of marginal fidelity of copy-milled and CAD/CAM all ceramic crowns

Jeong SM, Kang DW, Wolf C

  • KMID: 2195894
  • J Korean Acad Prosthodont.
  • 2001 Jun;39(3):243-249.
STATEMENT OF THE PROBLEM: The interest in all-ceramic restorations has increased as more techniques have become available. With the introduction of machinable dental ceramics and CAD/CAM systems of Copy-milling systems...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr