Korean J Ophthalmol.  2018 Dec;32(6):523-524. 10.3341/kjo.2018.0092.

Management of Postoperative Ocular Hypotony after Tube Surgery by Stenting Using Two 5-0 Nylon Threads

Affiliations
  • 1Department of Ophthalmology, Kim's Eye Hospital, Myung-Gok Eye Research Institute, Konyang University College of Medicine, Seoul, Korea. brainh@hanmail.net

Abstract

No abstract available.


MeSH Terms

Nylons*
Ocular Hypotension*
Stents*
Nylons

Figure

  • Fig. 1 Anterior segment photographs of (A–C) intraoperative and (D) postoperative intraluminal stenting of the tube using two 5-0 nylon threads. Two threads of 5-0 nylon were (A,B) stented and (C) cut with an ab interno approach. (E,F) To reduce the risk of stent displacement, bent threads can be used.


Reference

1. Rietveld E, van der Veen AJ. Postoperative pressure regulation in glaucoma shunt surgery: focal tube constriction is not the answer. J Glaucoma. 2004; 13:216–220.
2. Kim MK, Hwang YH, Ahn BH. Implantation of a modified baerveldt glaucoma implant with a smaller tube and intraluminal stent. Korean J Ophthalmol. 2017; 31:90–91.
Article
3. Han JC, Hwang YH, Ahn BH. Membrane-tube-type glaucoma shunt device for refractory glaucoma surgery. Graefes Arch Clin Exp Ophthalmol. 2017; 255:163–169.
Article
4. Ahn BH, Hwang YH, Han JC. Novel membrane-tube type glaucoma shunt device for glaucoma surgery. Clin Exp Ophthalmol. 2016; 44:776–782.
Article
5. Feinstein M, Moussa K, Han Y. Ab interno tube occlusion for postoperative hypotony in a patient with an Ahmed glaucoma drainage device. J Glaucoma. 2018; 27:e61–e63.