J Korean Orthop Assoc.  1994 Apr;29(2):641-654. 10.4055/jkoa.1994.29.2.641.

Press-Fit Condylar Total Knee Arthroplasty

Abstract

The goal of total knee replacement is to relieve pain, to stabilize joint movement and to correct deformity. It is indicated for patients with rheumatoid arthritis, osteoarthritis and severe post-traumatic arthritis. The author analyzed 71 patients(106 cases), who received the PFC type of total knee replacement from August 1992 and the results were as follows; 1. Among the 71 patients, male was 8 patients and female was 63 patients whose average age was 56 years and average follow up period was 24 months, ranged from 8 months to 3 years 8 months. 2. Rheumatoid arthritis was the most common cause with 31 patients(56 cases) followed by osteoarthritis with 39 patients(49 cases). There was also one patient(1 case) that showed bony union of the knee due to old tuberculosis. The average duration of the illness was 12 years and the average weight of the patients was 57.7kg. 3. Flexion contracture decreased from an average of 21 degrees to 5 degrees after the operation. The range of motion increased from an average of 92 degrees before the operation to 117 degrees afterwards in cases of rheumatoid arthritis and decreased slightly from 108 degrees to 106 degrees in cases of osteoarthritis. 4. The tibiofemoral angle was corrected from an average 1.5 degrees varus before the operation to an average 6.7 degrees valgus after operation. Eighty seven percent of patients with rheumatoid arthritis showed valgus deformity and seventy eight percent of degenerative osteoarthritis patients showed varus deformity preoperatively. 5. Radiographically, the joint line position shifted an average 2.3mm in rheumatoid arthritis and an average 0.3mm in osteoarthritis. The component position, the femoral flexion was an average 89.6 degrees in the anteroposterior view, an average 87 degrees in the lateral view. 6. The thickness of the patella measured in the operating room of 61 cases was an average 21mm and after resection of patella, the remaining bone measured an average of 13.6mm. 7. To achieve soft tissue balance, 29 patients(33 cases) underwent medial stripping and 23 patients(30 cases) had patella lateral release. 8. The Insall Knee Rating Score was used to evaluate the results. The results were 69 cases excellent, 33 cases good, 3 fair and 1 poor. Ninety two percent of the patients had good or excellent results in average 24 months follow-up. 9. The complications consisted of one case of delayed deep infection, one case of patellar subluxation and one case of supracondylar fracture of the femur.


MeSH Terms

Arthritis
Arthritis, Rheumatoid
Arthroplasty, Replacement, Knee*
Congenital Abnormalities
Contracture
Female
Femur
Follow-Up Studies
Humans
Joints
Knee
Male
Operating Rooms
Osteoarthritis
Patella
Range of Motion, Articular
Tuberculosis
Full Text Links
  • JKOA
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr