The Changes in Anterior Chamber Depth and Refractive Error Associated with Diverse Intraocular Lenses

Affiliations
  • 1Department of Ophthalmology and Visual Science, Yeouido St. Mary's Hosptal, The Catholic University of Korea College of Medicine, Seoul, Korea. sara514@catholic.ac.kr

Abstract

PURPOSE
The changes in anterior chamber depth (ACD) and refractive error in pseudophakia with 6 types of intraocular lenses (IOLs) after cataract surgery were compared in the present study.
METHODS
The medical records of 108 eyes (73 patients) who underwent cataract surgery with 6 types of IOLs, 5 types of single-piece IOLs and 1 type of 3-piece IOLs between March 2007 and April 2010 were retrospectively reviewed. ACD and refractive error were measured preoperatively, and at 1 day, 1 week, 1 month and 3 months postoperatively and the data were extracted and analyzed.
RESULTS
In the case of the SN60WF lens, the ACD was significantly shallow as compared to other IOLs at each follow-up period and refractive error was significantly myopic at 3 months postoperatively. In the case of SN60WF and ZA9003 lenses, the ACD was significantly changed at 3 months postoperatively from 1 day postoperatively. In the case of the MI60 lens, refractive error was slightly hyperopic, but not statistically significant.
CONCLUSIONS
There was difference in ACD changes after cataract surgery associated with various IOLs, which affected the postoperative refractive errors.

Keyword

Anterior chamber depth; Intraocular lenses; Refractive error

MeSH Terms

Anterior Chamber
Cataract
Eye
Follow-Up Studies
Lenses, Intraocular
Medical Records
Pseudophakia
Refractive Errors
Retrospective Studies

Figure

  • Figure 1. The postoperative mean anterior chamber depth (ACD) in 6 types of IOL. In the SN60W F, the ACD is significantly shallow as compared to other IOLs at each follow-up period.

  • Figure 2. The postoperative differences of mean anterior chamber depth after cataract surgery. In the SN60W F and ZA9003, there is significant change in ACD at 3 months postoperatively from 1 day postoperatively.

  • Figure 3. The postoperative refractive error (mean spherical equivalent differences) between the target refraction and the actual refraction at each period. In the SN60W F, refractive error is significantly myopic at 3 months postoperativlely. In the MI60, refractive error is slightly hyperopic, but not statistically significant.


Cited by  1 articles

Accuracy of Three Intraocular Lens-power Formulas in Predicting Refractive Outcomes in Different Intraocular Lenses
Sung Il Kang, Kun Moon, Jong Hwa Jun
J Korean Ophthalmol Soc. 2016;57(12):1891-1896.    doi: 10.3341/jkos.2016.57.12.1891.


Reference

References

1. John T, Shah AA. New surgical technique: upside-down phacoemulsification with posterior chamber intraocular lens and Descemet's stripping automated endothelial keratoplasty. Ann Ophthalmol (Skokie). 2009; 41:16–23.
2. Olsen T, Thim K, Corydon L. Theoretical versus SRK I and SRK II calculation of intraocular lens power. J Cataract Refract Surg. 1990; 16:217–25.
Article
3. Remsch H, Kampmeier J, Muche R, et al. [Comparison of the optical coherence method (Zeiss IOL-Master) with two ultrasono-graphic biometric methods for the calculation of posterior chamber intraocular lenses after phacoemulsification as part of clinical routine]. Klin Monbl Augenheilkd. 2004; 221:837–42.
4. Saka N, Moriyama M, Shimada N, et al. Changes of axial length measured by IOL master during 2 years in eyes of adults with pathologic myopia. Graefes Arch Clin Exp Ophthalmol. 2012.
5. van der Linden JW, van Velthoven M, van der Meulen I, et al. Comparison of a new-generation sectorial addition multifocal intraocular lens and a diffractive apodized multifocal intraocular lens. J Cataract Refract Surg. 2012; 38:68–73.
Article
6. López-Gil N, Montés-Micó R. New intraocular lens for achromatizing the human eye. J Cataract Refract Surg. 2007; 33:1296–302.
Article
7. Holladay JT, Moran JR, Kezirian GM. Analysis of aggregate surgically induced refractive change, prediction error, and intraocular astigmatism. J Cataract Refract Surg. 2001; 27:61–79.
Article
8. Chen MJ, Liu YT, Tsai CC, et al. Relationship between central cor-neal thickness, refractive error, corneal curvature, anterior chamber depth and axial length. J Chin Med Assoc. 2009; 72:133–7.
Article
9. Olsen T. Prediction of the effective postoperative (intraocular lens) anterior chamber depth. J Cataract Refract Surg. 2006; 32:419–24.
Article
10. Watson A, Armstrong R. Contact or immersion technique for axial length measurement? Aust N Z J Ophthalmol. 1999; 27:49–51.
11. Høvding G, Natvik C, Sletteberg O. The refractive error after implantation of a posterior chamber intraocular lens. The accuracy of IOL power calculation in a hospital practice. Acta Ophthalmol. 1994; 72:612–6.
Article
12. Tanaka T. Refractive error in VA-60 BB acrylic intraocular lenses. J Cataract Refract Surg. 2005; 31:1673–4.
13. Erickson P. Effects of intraocular lens position errors on postoperative refractive error. J Cataract Refract Surg. 1990; 16:305–11.
Article
14. Oh SH, Kim JK, Lee DH. The clinical results of hydrophobic single-piece acrylic intraocluar lenses after cataract surgery. J Korean Ophthalmol Soc. 2004; 45:2007–13.
15. Chae JK, Jang JW, Choi TH, Lee HB. Changes in refraction and anterior chamber depth according to the type of intraocular lenses. J Korean Ophthalmol Soc. 2006; 47:1935–42.
16. Moon SH, Lee DH, Lew HM. The change of anterior chamber depth according to the types of intraocular lens. J Korean Ophthalmol Soc. 1998; 39:2280–5.
17. Rose LT, Moshegov CN. Comparison of the Zeiss IOLMaster and applanation A-scan ultrasound: biometry for intraocular lens calculation. Clin Experiment Ophthalmol. 2003; 31:121–4.
Article
18. Brandser R, Haaskjold E, Drolsum L. Accuracy of IOL calculation in cataract surgery. Acta Ophthalmol Scand. 1997; 75:162–5.
Article
19. Szaflik J, Kaminska A, Gajda S, Jedruch A. [Accuracy of the SRK II, SRK/T, Holladay and Hoffer Q IOL power calculation formulas -in hyperopic patients after phacoemulsification]. Klin Oczna. 2005; 107:615–9.
20. Zaldivar R, Shultz MC, Davidorf JM, Holladay JT. Intraocular lens power calculations in patients with extreme myopia. J Cataract Refract Surg. 2000; 26:668–74.
Article
21. Armstrong TA. Refractive effect of capsular bag lens placement with the capsulorhexis technique. J Cataract Refract Surg. 1992; 18:121–4.
Article
22. Minassian DC, Rosen P, Dart JK, et al. Extracapsular cataract extraction compared with small incision surgery by phacoemulsification: a randomised trial. Br J Ophthalmol. 2001; 85:822–9.
Article
23. Shammas HJ, Shammas MC, Garabet A, et al. Correcting the cor-neal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis. Am J Ophthalmol. 2003; 136:426–32.
Article
24. Celikkol L, Ahn D, Celikkol G, Feldman ST. Calculating intraocular lens power in eyes with keratoconus using videokeratography. J Cataract Refract Surg. 1996; 22:497–500.
Article
25. Shioya M, Ogino N, Shinjo U. Change in postoperative refractive error when vitrectomy is added to intraocular lens implantation. J Cataract Refract Surg. 1997; 23:1217–20.
Article
26. Holladay JT, Prager TC, Ruiz RS, et al. Improving the predictability of intraocular lens power calculations. Arch Ophthalmol. 1986; 104:539–41.
Article
27. Whitehouse G. Effect of lens style on postoperative refractive astigmatism after small incision cataract surgery. Clin Experiment Ophthalmol. 2000; 28:290–2.
Article
28. Petternel V, Menapace R, Findl O, et al. Effect of optic edge design and haptic angulation on postoperative intraocular lens position change. J Cataract Refract Surg. 2004; 30:52–7.
Article
29. Olsen T, Corydon L, Gimbel H. Intraocular lens power calculation with an improved anterior chamber depth prediction algorithm. J Cataract Refract Surg. 1995; 21:313–9.
Article
30. Olsen T. Sources of error in intraocular lens power calculation. J Cataract Refract Surg. 1992; 18:125–9.
Article
31. Arai M, Ohzuno I, Zako M. Anterior chamber depth after posterior chamber intraocular lens implantation. Acta Ophthalmol. 1994; 72:694–7.
Article
32. Wirtitsch MG, Findl O, Menapace R, et al. Effect of haptic design on change in axial lens position after cataract surgery. J Cataract Refract Surg. 2004; 30:45–51.
Article
33. Landers J, Liu H. Choice of intraocular lens may not affect refractive stability following cataract surgery. Clin Experiment Ophthalmol. 2005; 33:34–40.
34. Lee JY, Lee SH, Chung SK. Decentration, tilt and anterior chamber depth: aspheric vs spheric acrylic intraocular lens. J Korean Ophthalmol Soc. 2009; 50:852–7.
Article
35. Amzallag T, Pynson J. [Lens biomaterials for cataract surgery]. J Fr Ophtalmol. 2007; 30:757–67.
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr