Comparison of Clinical Outcomes in Implantable Collamer Lens Implantation between AQUA ICL(R) and Conventional ICL

Affiliations
  • 1HanGil Eye Hospital, Incheon, Korea. chobj@empal.com

Abstract

PURPOSE
To compare the clinical outcomes between AQUA ICL(R) (V4C) and conventional implantable collamer lens (ICL, V4B) in patients with high myopia.
METHODS
We compared preoperative and postoperative visual acuities, spherical equivalent, intraocular pressure, postoperative vault and visual quality assessed using optical quality analyzing system (OQAS(R)) between 20 eyes implanted with ICL (V4B) and 22 eyes implanted with AQUA ICL(R) (V4C).
RESULTS
Visual acuity (log MAR) and spherical equivalent at postoperative 3 months were 0.06 +/- 0.09 and -0.26 +/- 0.17 D in the V4B group and 0.03 +/- 0.03 and -0.23 +/- 0.19 D in the V4C group, respectively. There was no statistical difference in visual acuity and spherical equivalent between the 2 groups (p > 0.05). Postoperative intraocular pressure (IOP) elevated significantly in both groups until 6 hours after the operation (p < 0.05) compared with preoperative IOP. No significant IOP elevation was observed from the first postoperative day to postoperative 3 months (p > 0.05). V4C resulted in lower IOP than V4B 6 hours postoperatively. In ICL (V4B) and AQUA ICL(R) (V4C) groups, the objective scattering index (OSI) was 1.29 +/- 0.90 and 1.36 +/- 0.68, modulation transfer function (MTF) cut off value was 29.62 +/- 11.31 c/deg and 29.61 +/- 9.56 c/deg and Sterhl ratio was 0.18 +/- 0.07 and 0.17 +/- 0.04, respectively, 3 months postoperatively. None of these values were significantly different between the 2 groups.
CONCLUSIONS
AQUA ICL(R) (V4C) implantation is an effective, convenient and safe surgery for myopia correction and yields better outcome than ICL (V4B) in terms of early postoperative IOP.

Keyword

AQUA ICL; Conventional ICL; Implantable collamer lens; Intraocular pressure

MeSH Terms

Humans
Intraocular Pressure
Myopia
Visual Acuity

Figure

  • Figure 1. Intraocular pressure (IOP) changes in two groups postoperatively. Both of conventional implantable collamer lens (ICL) (V4B) group and AQUA ICL® (V4C) group presented temporary elevation of IOP postoperatively, which was stabilized thereafter. At postoperative 6 hours, IOP of V4B group showed higher value (27.36 ± 9.25) than that of V4C group (18.44 ± 4.21) significantly ( p = 0.001). Other val-ues at different instances showed no statistically significant difference. Preop = preoperative period. * p-value within each group was acquired from Wilcoxon signed rank test; † p-values between 2 groups were acquired from Mann-Whitney U-test.


Reference

References

1. Heitzmann J, Binder PS, Kassar BS, Nordan LT. The correction of high myopia using the excimer laser. Arch Ophthalmol. 1993; 111:1627–34.
Article
2. Holladay JT, Dudeja DR, Chang J. Functional vision and corneal changes after laser in situ keratomileusis determined by contrast sensitivity, glare testing, and corneal topography. J Cataract Refract Surg. 1999; 25:663–9.
Article
3. Lee SY, Cheon HJ, Baek TM, Lee KH. Implantable contact lens to correct high myopia (Clinical Study with 24 months follow-up). J Korean Ophthalmol Soc. 2000; 41:1515–22.
4. Dejaco-Ruhswurm I, Scholz U, Pieh S. . Long-term endothe-lial changes in phakic eyes with posterior chamber intraocular lenses. J Cataract Refract Surg. 2002; 28:1589–93.
Article
5. Edelhauser HF, Sanders DR, Azar R. . Corneal endothelial as-sessment after ICL implantation. J Cataract Refract Surg. 2004; 30:576–83.
Article
6. Sanders DR. Anterior subcapsular opacities and cataracts 5 years after surgery in the visian implantable collamer lens FDA trial. J Refract Surg. 2008; 24:566–70.
Article
7. Sánchez-Galeana CA, Zadok D, Montes M. . Refractory intra-ocular pressure increase after phakic posterior chamber intraocular lens implantation. Am J Ophthalmol. 2002; 134:121–3.
Article
8. Smallman DS, Probst L, Rafuse PE. Pupillary block glaucoma sec-ondary to posterior chamber phakic intraocular lens implantation for high myopia. J Cataract Refract Surg. 2004; 30:905–7.
Article
9. Murphy PH, Trope GE. Monocular blurring. A complication of YAG laser iridotomy. Ophthalmology. 1991; 98:1539–42.
10. Kumar N, Feyi-Waboso A. Intractable secondary glaucoma from hyphema following YAG iridotomy. Can J Ophthalmol. 2005; 40:85–6.
Article
11. Siam GA, de Barros DS, Gheith ME. . Post-peripheral iridot-omy inflammation in patients with dark pigmentation. Ophthalmic Surg Lasers Imaging. 2008; 39:49–53.
Article
12. Spaeth GL. The normal development of the human anterior cham-ber angle: a new system of descriptive grading. Trans Ophthalmol Soc U K. 1971; 91:709–39.
13. Alfonso JF, Lisa C, Fernández-Vega Cueto L. . Clinical out-comes after implantation of a posterior chamber collagen copoly-mer phakic intraocular lens with a central hole for myopic correction. J Cataract Refract Surg. 2013; 39:915–21.
Article
14. Higueras-Esteban A, Ortiz-Gomariz A, Gutiérrez-Ortega R. . Intraocular pressure after implantation of the visian implantable collamer lens with CentraFLOW without iridotomy. Am J Ophthalmol. 2013; 156:800–5.
Article
15. Uozato H, Shimizu K, Kawamorita T, Ohmoto F. Modulation transfer function of intraocular collamer lens with a central artifi-cial hole. Graefes Arch Clin Exp Ophthalmol. 2011; 249:1081–5.
Article
16. Park CW, Lee YE, Joo CK. Changes in optical quality of cataract patients' corrected visual acuity before and after phacoemulsification. J Korean Ophthalmol Soc. 2013; 54:1208–12.
Article
17. Shin KH, Kim KH, Kwon JW. Two cases of glare after Iridotomy for phakic intraocular lens implantation. J Korean Ophthalmol Soc. 2011; 52:1537–40.
Article
18. Zadok D, Chayet A. Lens opacity after neodymium: YAG laser iri-dectomy for phakic intraocular lens implantation. J Cataract Refract Surg. 1999; 25:592–3.
19. Dhawahir-Scala FE, Clark D. Neodymium: YAG laser peripheral iridotomy: cause of a visually incapacitating cataract? Ophthalmic Surg Lasers Imaging. 2006; 37:330–2.
20. Jeng S, Lee JS, Huang SC. Corneal decompensation after argon la-ser iridectomy-a delayed complication. Ophthalmic Surg. 1991; 22:565–9.
Article
21. Wu SC, Jeng S, Huang S, Lin SM. Corneal endothelial damage af-ter neodymium: YAG laser iridotomy. Ophthalmic Surg Lasers. 2000; 31:411–6.
22. Anderson JE, Gentile RC, Sidoti PA, Rosen RB. Stage 1 macular hole as a complication of laser iridotomy. Arch Ophthalmol. 2006; 124:1658–60.
Article
23. Kawamorita T, Uozato H, Shimizu K. Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation. Graefes Arch Clin Exp Ophthalmol. 2012; 250:935–9.
Article
24. Martinez-de-la-Casa JM, Garcia-Feijoo J, Castillo A, Garcia-Sanchez J. Reproducibility and clinical evaluation of rebound tonometry. Invest Ophthalmol Vis Sci. 2005; 46:4578–80.
Article
25. Abraham LM, Epasinghe NC, Selva D, Casson R. Comparison of the ICare rebound tonometer with the Goldmann applanation ton-ometer by experienced and inexperienced tonometrists. Eye (Lond). 2008; 22:503–6.
Article
26. Allan BD, Argeles-Sabate I, Mamalis N. Endophthalmitis rates af-ter implantation of the intraocular Collamer lens: survey of users between 1998 and 2006. J Cataract Refract Surg. 2009; 35:766–9.
Article
27. Scuderi GL, Cascone NC, Regine F. . Validity and limits of the rebound tonometer (ICare[R]): clinical study. Eur J Ophthalmol. 2011; 21:251–7.
Full Text Links
  • JKOS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr