J Korean Radiol Soc.  1999 Dec;41(6):1101-1106. 10.3348/jkrs.1999.41.6.1101.

Efficiency of Ultrasonography and CT Angiography in Follow-up Studies of Carotid Stent and Percutaneous Transluminal Angioplasty

Affiliations
  • 1Department of Radiology, Pundang CHA General Hospital, Pochon CHA University, College of Medicine, Korea.
  • 2Department of Neurosurgery, Pundang CHA General Hospital, Pochon CHA University, College of Medicine, Korea.
  • 3Department of Neurology, Pundang CHA General Hospital, Pochon CHA University, College of Medicine, Korea.

Abstract

PURPOSE: The aim of this study was to determine a more appropriate method for follow-up of carotid stenting by comparing the efficiency of US and CT angiography. MATERIALS AND METHODS: Eleven carotid arteries of seven patients(men: 5, women: 2, mean age: 56.4years) who underwent stent placement and percutaneous transluminal angioplasty(PTA) because of carotid stenosis were studied. The follow-up periods ranged from three to eleven(mean, five) months, and US and CT angiography were performed in one day. Color duplex sonography was performed with a 10 MHz linear array transducer. After spiral CT scan were obtained, MPR images were reconstructed on a workstation. Retrospective imaging analysis specifically focused on [1] stent configuration, [2] the accuracy of internal diameter measurement, [3] the detection of blood flow and the measurement of blood flow velocity, [4] the presence of atheroma and intraluminal thrombi, [5] the measurement of stent location, and [6] artifacts. RESULT: US was more accurate than CT angiography for measuring internal diameter. In all cases, US and CT angiography were able to detect the blood flow at carotid artery, and utilizing the Doppler spectrum, flow velocity was measured. US showed atheromas in all cases but CT angiography demonstrated calcified atheromas in three cases only. In six cases, US failed to determine stent location, though in this respect CT angiography was successful in all cases. Artifacts of US were small reverbe ration artifact(11/11) of the stent and a defective color Doppler signal caused by acoustic shadowing of atheroma calcification(3/11). Artifacts of CT angiogrpahy were hard-beam artifact of the stent(11/11) and motion artifact(3/11). CONCLUSION: US was superior to CT angiography in accuracy of measuring stent diameter, hemodynamic assessment, high-resolution views of the luminal state of the stent and minimal artifacts for the non-inva s i ve follow-up studies of carotid stenting.

Keyword

Carotid arteries, interventional procedure; Carotid arteries, US

MeSH Terms

Acoustics
Angiography*
Angioplasty*
Artifacts
Blood Flow Velocity
Carotid Arteries
Carotid Stenosis
Female
Follow-Up Studies*
Hemodynamics
Humans
Phenobarbital
Plaque, Atherosclerotic
Retrospective Studies
Shadowing (Histology)
Stents*
Tomography, Spiral Computed
Transducers
Ultrasonography*
Phenobarbital
Full Text Links
  • JKRS
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr