J Korean Acad Prosthodont.
2000 Aug;38(4):492-499.
Staining Resistance of The Soft Denture Liners
Abstract
- This study was investigated to compare the staining resistance of soft denture liners. Specimens wee made of Coe-soft. Coe-Comfort, Soft-liner, Visco-gel, and were stored in 1% methyleneblue solution for 24 hours. The amounts of color change before and after treatment with mono-poly and thermocycling were measured by colorimeter(TC-6FX, Tokyo Denshoku Co. Ltd, Japan) for evaluation of staining resistance. The following conclusions were drawn from this study. 1. The staining resistance of Visco-gel was increased, but there was no changer of staining resistance in Coe-soft, Coe-comfort, and Soft-liner after treatment with monopoly. 2. The staining resistance of the Coe-comfort was the least in all soft denture liners. 3. The staining resistance of Visco-gel and Soft-liner were decreased after thermocycling.