1. Callaghan JJ, Dysart SH, Savory CG. The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series. J Bone Joint Surg Am. 1988. 70:337–346.
Article
2. Engh CA, Bobyn JD. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res. 1988. 231:7–28.
Article
3. Engh CA, Bobyn JD. Biological fixation in total hip arthroplasty. Slack. 1985. 135–189.
4. Kim YH, Kim VE. Cementless porous-coated anatomic medullary locking total hip prosthesis. J Arthroplasty. 1994. 9:243–252.
5. Claus AM, Hopper RH Jr, Engh CA. Fracture of the greater trochanter induced by osteolysis with the anatomic medullary locking prosthesis. J Arthroplasty. 2002. 17:706–712.
6. Dowd JE, Sychterz CJ, Young AM, Engh CA. Characterization of long-term femoral-head-penetration rates. Association with and prediction of osteolysis. J Bone Joint Surg Am. 2000. 82:1102–1107.
7. Wagner M, Wagner H. Medium-term resuts of a modern metal-on-metal system in total hip replacement. Clin Orthop Relat Res. 2000. 379:123–133.
8. Jacobs JJ, Rosenbaum DH, Hay RM, Gitelis S, Black J. Early sarcomatous degeneration near a cementless hip replacement. A case report and review. J Bone Joint Surg Br. 1992. 74:740–744.
Article
9. Langkamer VG, Case CP, Collins C, et al. Tumors around implants. J Arthroplasty. 1997. 12:461–464.
Article
10. Christel PS. Biocompatibility of surgical-grade dense polycrystalline alumina. Clin Orthop Relat Res. 1992. 282:10–18.
Article
11. Garino JP. Modern ceramic-on-ceramic total hip systems in the United States: early results. Clin Orthop Relat Res. 2000. 379:41–47.
12. Kim SY, Kim YG, Yeo JY, Kim DH, Ihn JC. Ceramic on ceramic bearing total hip arthroplasty in young patients with osteonecrosis of femoral head. J Korean Orthop Assoc. 2004. 39:233–238.
13. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969. 91:737–755.
14. Gruen TA, McNeice GM, Amstutz HC. "Modes of failure" of cemented stem type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979. 141:17–27.
15. Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987. 69:45–55.
Article
16. Brooker AF, Bowerman JW, Robinson RA, Riley LH Jr. Ectopic ossification following total hip arthroplasty. Incidence and a method of classification. J Bone Joint Surg Am. 1973. 55:1629–1632.
17. DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976. 121:20–32.
Article
18. Livermore J, Ilstrup D, Morrey B. Effect of femoral head size on wear of the polyethylene acetabular component. J Bone Joint Surg Am. 1990. 72:518–528.
Article
19. Kawamura H, Dunbar MJ, Murray P, Bourne RB, Rorabeck CH. The porous coated anatomic total hip replacement. A ten to fourteen-year follow-up study of a cementless total hip arthroplasty. J Bone Joint Surg Am. 2001. 83:1333–1338.
20. Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990. 257:107–128.
Article
21. Yang IH, Park SH, Han CD. Cementless total hip arthroplasty using ceramic-on-ceramic Summit® System: 3 years follow up. J Korean Hip Soc. 2007. 19:9–15.
22. Yoo MC, Cho YJ, Kim KI, et al. Long term follow up study of cementless total hip arthroplasty for osteonecrosis of the femoral head -Minimum 10-years follow-up study-. J Korean Hip Soc. 2004. 16:1–9.
23. Engh CA Jr, Culpepper WJ 2nd, Engh CA. Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J Bone Joint Surg Am. 1997. 79:177–184.
Article
24. Hwang SK, Son YK. The clinical and radioraphic results of primary cementless AML total hip arthroplasties. -Minimun 10-years follow-up study-. J Korean Hip Soc. 1999. 11:142–149.
25. Han CD, Choe WS, Yoo JH. Effect of the polyethylene wear on osteolysis in cementless primary total hip arthroplasty: Minimun 5 years follow-up study. J Korean Orthop Assoc. 1998. 33:746–758.
26. Barrack RL, Jasty M, Bragdon C, Haire T, Harris WH. Thigh pain despite bone ingrowth into uncemented femoral stems. J Bone Joint Surg Br. 1992. 74:63–66.
Article
27. Campbell AC, Rorabeck CH, Bourne RB, Chess D, Nott L. Thigh pain after cementless hip arthroplasty. J Bone Joint Surg Br. 1992. 74:63–66.
28. Morlock WJ, Nassutt R, Janssen R, Wilimann G, Honl M. Mismatched wear couple zirconium oxide and aluminum oxide in total hip arthroplasty. J Arthroplasty. 2001. 16:1071–1074.
Article
29. Walter WL, O'toole GC, Walter WK, Ellis A, Zicat BA. Squeaking in ceramic-on-ceramic hips: the importance of acetabular component orientation. J Arthroplasty. 2007. 22:496–503.
30. Baek SH, Kim SY. Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis. J Bone Joint Surg Am. 2008. 90:1314–1320.
Article