J Korean Orthop Assoc.  2013 Dec;48(6):449-456. 10.4055/jkoa.2013.48.6.449.

Comparison of Two Year Follow-Up Results in High Flexion Total Knee Arthroplasty with Lospa and Scorpio NRG

Affiliations
  • 1Department of Orthpaedic Surgery, Sun General Hospital, Daejeon, Korea. mydangjang@naver.com

Abstract

PURPOSE
The purpose of this study is to evaluate the clinical and radiologic results after high flexion Lospa (Corentec Inc.) and Scorpio NRG (Stryker Inc.) total knee arthroplasty.
MATERIALS AND METHODS
We prospectively compared 205 knees in 128 patients who underwent arthroplasty using Lospa (group A) and 164 knees in 102 patients who underwent arthroplasty using Scorpio NRG (group B) from September 2010 to March 2012 at Department of Orthopaedic Surgery, Sun General Hospital (Daejeon, Korea). Mean follow-up period was 23 months in group A and 24 months in group B. The radiologic analysis included the change of mechanical axis deviation and femoro-tibial angle, implant position (alpha, beta, gamma, delta), and patellar tilt. The clinical results were evaluated according to hospital for special surgery (HSS), knee society score (KSS), and range of motion.
RESULTS
Mechanical axis deviations were change in varus from 34.8 mm to 2.6 mm (p=0.02) in group A, and change in varus from 34.3 mm to 3.1 mm (p=0.04) in group B; no statistically significant difference was observed between them (p=0.13). Femoro-tibial angles were varus 4.3degrees to valgus 6.6degrees (p=0.02) in group A, and varus 4.4degrees to valgus 6.5degrees (p=0.03) in group B; no significant difference was observed between them (p=0.25). No significant difference in implant position was observed between the two groups (p=0.25 in alpha, p=0.17 in beta, p=0.12 in gamma, p=0.17 in delta). Mean HSS improved from 48.5 to 93.6 (p=0.02) in group A, and from 41.4 to 94.4 (p=0.01) in group B.
CONCLUSION
Lospa total knee arthroplasty showed excellent early radiologic, clinical results and no statistically significant difference in the results was observed between Lospa and Scorpio NRG.

Keyword

total knee arthroplasty; high flexion; Lospa

MeSH Terms

Arthroplasty*
Axis, Cervical Vertebra
Follow-Up Studies*
Hospitals, General
Humans
Knee*
Prospective Studies
Range of Motion, Articular
Solar System

Figure

  • Figure 1 Deep flexion favoring design of (A) Lospa total knee arthroplasty requires cutting of the posterior condyle to 10 mm compared with 8 mm of (B) Scorpio NRG.

  • Figure 2 A 72-year-old female showed (A) advanced osteoarthritis on both knees with left knee subluxation. She underwent Lospa total knee arthroplasty and demonstrated well positioned implants. (B) The α angle was measured between the parallel to the femoral condyles and a line drawn along the femoral shaft axis. The β angle was calculated between the parallel to the tibial metal baseplate and a line drawn along the tibial axis shaft. (C) Whereas sagittal tibial δ and femoral γ angles were measured on lateral knee radiographs with the patient lying and the knee flexion.


Reference

1. Endres S, Wilke A. High flexion total knee arthroplasty - mid-term follow up of 5 years. Open Orthop J. 2011; 5:138–142.
Article
2. Dennis DA, Komistek RD, Colwell CE Jr, et al. In vivo anteroposterior femorotibial translation of total knee arthroplasty: a multicenter analysis. Clin Orthop Relat Res. 1998; 356:47–57.
3. Kim YH, Sohn KS, Kim JS. Range of motion of standard and high-flexion posterior stabilized total knee prostheses. A prospective, randomized study. J Bone Joint Surg Am. 2005; 87:1470–1475.
4. Endres S. High-flexion versus conventional total knee arthroplasty: a 5-year study. J Orthop Surg (Hong Kong). 2011; 19:226–229.
Article
5. Zelle J, Janssen D, Van Eijden J, De Waal Malefijt M, Verdonschot N. Does high-flexion total knee arthroplasty promote early loosening of the femoral component? J Orthop Res. 2011; 29:976–983.
Article
6. Massin P, Dupuy FR, Khlifi H, et al. Does hyperflex total knee design improve postoperative active flexion? Orthop Traumatol Surg Res. 2010; 96:376–380.
Article
7. Bin SI, Nam TS. Early results of high-flex total knee arthroplasty: comparison study at 1 year after surgery. Knee Surg Sports Traumatol Arthrosc. 2007; 15:350–355.
8. Huang HT, Su JY, Wang GJ. The early results of high-flex total knee arthroplasty: a minimum of 2 years of follow-up. J Arthroplasty. 2005; 20:674–679.
Article
9. Song EK, Park SJ, Yoon TR, Park KS, Seo HY, Seon JK. Hi-flexion and gender-specific designs fail to provide significant increases in range of motion during cruciate-retaining total knee arthroplasty. J Arthroplasty. 2012; 27:1081–1084.
Article
10. Kim YH, Park JW, Kim JS. High-flexion total knee arthroplasty: survivorship and prevalence of osteolysis: results after a minimum of ten years of follow-up. J Bone Joint Surg Am. 2012; 94:1378–1384.
11. Han HS, Kang SB. Brief followup report: does high-flexion total knee arthroplasty allow deep flexion safely in Asian patients? Clin Orthop Relat Res. 2013; 471:1492–1497.
Article
12. Bauman RD, Johnson DR, Menge TJ, Kim RH, Dennis DA. Can a high-flexion total knee arthroplasty relieve pain and restore function without premature failure? Clin Orthop Relat Res. 2012; 470:150–158.
Article
13. Long WJ, Scuderi GR. High-flexion total knee arthroplasty. J Arthroplasty. 2008; 23:Suppl. 6–10.
Article
14. Zhang Y, Liu J, Tian MQ, et al. Effect of posterior condylar offset on knee flexion after high-flex posterior-stabilized total knee arthroplasty. Zhonghua Wai Ke Za Zhi. 2010; 48:764–768.
15. Bollars P, Luyckx JP, Innocenti B, Labey L, Victor J, Bellemans J. Femoral component loosening in high-flexion total knee replacement: an in vitro comparison of high-flexion versus conventional designs. J Bone Joint Surg Br. 2011; 93:1355–1361.
16. Han HS, Kang SB, Yoon KS. High incidence of loosening of the femoral component in legacy posterior stabilised-flex total knee replacement. J Bone Joint Surg Br. 2007; 89:1457–1461.
Article
17. Kurita M, Tomita T, Yamazaki T, et al. In vivo kinematics of high-flex mobile-bearing total knee arthroplasty, with a new post-cam design, in deep knee bending motion. Int Orthop. 2012; 36:2465–2471.
Article
18. Kellgren JH, Lawrence JS. Radiological assessment of osteo-arthrosis. Ann Rheum Dis. 1957; 16:494–502.
Article
19. Bindelglass DF, Vince KG. Patellar tilt and subluxation following subvastus and parapatellar approach in total knee arthroplasty. Implication for surgical technique. J Arthroplasty. 1996; 11:507–511.
20. Seon JK, Song EK. The accuracy of lower extremity alignment in a total knee arthroplasty using computer-assisted navigation system. J Korean Orthop Assoc. 2004; 39:566–571.
Article
21. Laskin RS. The effect of a high-flex implant on postoperative flexion after primary total knee arthroplasty. Orthopedics. 2007; 30:Suppl. 86–88.
22. Jung KH, Cho SD, Go SH, et al. Total knee arthroplasty with nexgen(r) system: 3-8 year follow-up results. J Korean Orthop Assoc. 2007; 42:730–736.
23. Akasaki Y, Matsuda S, Shimoto T, Miura H, Higaki H, Iwamoto Y. Contact stress analysis of the conforming post-cam mechanism in posterior-stabilized total knee arthroplasty. J Arthroplasty. 2008; 23:736–743.
Article
24. Abbas D, Gunn RS. Medium-term results of the Scorpio total knee replacement. Knee. 2006; 13:307–311.
Article
25. Thomsen MG, Husted H, Bencke J, Curtis D, Holm G, Troelsen A. Do we need a gender-specific total knee replacement? A randomised controlled trial comparing a high-flex and a gender-specific posterior design. J Bone Joint Surg Br. 2012; 94:787–792.
26. Lionberger DR, Eggers MD, Brewer KE, Fang L. Improved knee flexion following high-flexion total knee arthroplasty. J Orthop Surg Res. 2012; 7:22.
Article
27. Jia YT, Wang L, Zhang Y, Zhao C, Sun ZH, Liu J. Does mismatch of the femoral component aspect ratio influence the range of knee flexion after posterior-stabilized total knee arthroplasty? Chin J Traumatol. 2012; 15:152–157.
28. Kim YH, Yoon SH, Kim JS. Early outcome of TKA with a medial pivot fixed-bearing prosthesis is worse than with a PFC mobile-bearing prosthesis. Clin Orthop Relat Res. 2009; 467:493–503.
Article
Full Text Links
  • JKOA
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr