Korean J Blood Transfus.  2003 Jun;14(1):44-54.

Prestorage leukoreduced RBCs: Evaluation for two different quadruple collection bags with an inline RBC filter

Affiliations
  • 1Central Blood Center, Korean Red Cross, Seoul, Korea.
  • 2Seoul Nambu Blood Center, Korean Red Cross, Seoul, Korea.
  • 3Blood Services Bureau, Korean Red Cross, Seoul, Korea.
  • 4Department of Labolatory Medicine, Yonsei University College of Medicine, Seoul, Korea.
  • 5Department of Laboratory Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.

Abstract

BACKGROUND: The Korean Red Cross(KRC) are considering the introduction of prestorage leukoreduced RBCs, as it is thought one of best way to prevent WBC-associated adverse transfusion reactions. We evaluated two different quadruple top-and-bottom collection bags, specially designed for this purpose by two manufacturers(Boin Medica Co.,Ltd and Green Cross Medical Corporation, Korea), consisted of a CPD bag, a SAG-M bag and an inline RBC filter, either RCM1 (Pall Medical, U.S.A.) or BioR 01 1N (Fresenius Hemocare, Germany) each.
METHODS
Fifty one bags from Boin and sixty bags from Green Cross and consequent blood components were studied in twice over a period of two years. As an inline filter, Boin used RCM1 and Green Cross used RCM1(1st) and BioR 01 1N(2nd). They were divided into group A(filtration performed after processing of RBCs) and B(filtration performed after storage of overnight at 4 degrees C). WBC-reduced RBCs were tested for pH, plasma K+, plasma Hb and blood culture every 7 days to investigate storage time-dependent changes up to 42 days.
RESULTS
The results of pH, plasma K+ and plasma Hb from CPD added whole blood, RBCs, SAG-M added RBCs and WBC-reduced RBCs did not show significant differences. We observed both of adding SAG-M solution and filtration procedure did not effect on the prestorage leukoreduced RBCs. WBCs were removed effectively by prestorage filtration. But in the case of failed units, the design or method to integrate an RBC filter may be a cause for the failure.
CONCLUSION
We concluded that two different quadruple collection bags with integral RCM1 filter from Boin(2nd) and Green Cross(1st) are useful for production of prestorage leukoreduced RBCs.

Keyword

Prestorage leukoreduction; quadruple top-and bottom collection bag; inline filter

MeSH Terms

Blood Group Incompatibility
Filtration
Hydrogen-Ion Concentration
Plasma
Full Text Links
  • KJBT
Actions
Cited
CITED
export Copy
Close
Share
  • Twitter
  • Facebook
Similar articles
Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr