Monitoring Tumor Size Using PET with a Collimator during Boron Neutron Capture Therapy: Simulation Study

Yang HJ, Yoon DK, Suh TS

  • KMID: 2510100
  • Prog Med Phys.
  • 2020 Sep;31(S1):S55.
Purpose: The purpose of this study was to demonstrate the feasibility of sensing changes in a tumor during boron neutron capture therapy (BNCT) using a Monte Carlo simulation tool. Methods: In...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Simplified Sigmoidal Curve Fitting for 6 MV FFF Photon Beam of Halcyon to Determine Field Size for Beam Commissioning and Quality Assurance

Choi MG, Kim YJ, Yoon DK, Kim MS, Suh TS

  • KMID: 2510084
  • Prog Med Phys.
  • 2020 Sep;31(S1):S43.
Purpose: Delivery of a single energy 6 MV flattening filter free (FFF) photon beam is a main characteristic of an O-ring gantry type linear accelerator (linac) Halcyon. The purpose of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Reference based Simulation Study of Detector Comparison for BNCT-SPECT Imaging

Kim MS, Choi MG, Yoon DK, Suh TS

  • KMID: 2510053
  • Prog Med Phys.
  • 2020 Sep;31(S1):S25.
To investigate the optimal detector material for prompt gamma imaging during boron neutron capture therapy, in this study, we evaluated the characteristic regarding radiation reaction of available detector materials using...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
SPECT Image Analysis Using Computational ROC Curve Based on Threshold Setup

Kim MS, Shin HB, Kim S, Shim JG, Yoon DK, Suh TS

We proposed the objective ROC analysis method based on the setting of threshold value for evaluation of single photon emission computed tomography (SPECT) image. This proposed ROC analysis method uses...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of an Advanced Deformable Phantom to Analyze Dose Differences due to Respiratory Motion

Shin DS, Kang SH, Kim DS, Kim TH, Kim KH, Koo HJ, Cho MS, Ha JS, Yoon DK, Suh TS

The difference between three-dimensional (3D) and four-dimensional (4D) dose could be affected by factors such as tumor size and motion. To quantitatively analyze the effects of these factors, a phantom...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development Treatment Planning System Based on Monte-Carlo Simulation for Boron Neutron Capture Therapy

Kim MS, Kubo K, Monzen H, Yoon DK, Shin HB, Kim S, Suh TS

The purpose of this study is to develop the treatment planning system (TPS) based on Monte-Carlo simulation for BNCT. In this paper, we will propose a method for dose estimation...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluating Correlation between Geometrical Relationship and Dose Difference Caused by Respiratory Motion Using Statistical Analysis

Shin DS, Kang SH, Kim DS, Kim TH, Kim KH, Cho MS, Noh YY, Yoon DK, Suh TS

Dose differences between three-dimensional (3D) and four-dimensional (4D) doses could be varied according to the geometrical relationship between a planning target volume (PTV) and an organ at risk (OAR). The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dexmedetomidine combined with midazolam vs. dexmedetomidine alone for sedation during spinal anesthesia

Yoon DK, Ban JS, Lee SG, Lee JH, Kim E, An J

BACKGROUND: Dexmedetomidine is a useful sedative agent for spinal anesthesia. However, it has been reported that dexmedetomidine decreases heart rate in a dose-dependent manner. In the current study, we compared...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pixelized Measurement of (99m)Tc-HDP Micro Particles Formed in Gamma Correction Phantom Pinhole Scan: a Reference Study

Jung JY, Cheon GJ, Lee YS, Ha S, Chae MH, Chung YA, Yoon DK, Bahk YW

PURPOSE: Currently, traumatic bone diseases are diagnosed by assessing the micro (99m)Tc-hydroxymethylene diphosphonate (HDP) uptake in injured trabeculae with ongoing osteoneogenesis demonstrated by gamma correction pinhole scan (GCPS). However, the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Preliminary Study for Imaging of Therapy Region from Boron Neutron Capture Therapy

Jung JY, Yoon DK, Han SM, Jang H, Suh TS

The purpose of this study was to confirm the feasibility of imaging of therapy region from the boron neutron capture therapy (BNCT) using the measurement of the prompt gamma ray...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Comparative Analysis of External Dose Reconstruction in EPID and Internal Dose Measurement Using Monte Carlo Simulation

Jung JY, Yoon DK, Suh TS

The purpose of this study is to evaluate and analyze the relationship between the external radiation dose reconstruction which is transmitted from the patient who receives radiation treatment through electronic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Testosterone Replacement Treatment in Testosterone Deficiency Syndrome Patients with Metabolic Syndrome

Jeong SM, Ham BK, Park MG, Oh MM, Yoon DK, Kim JJ, Moon DG

PURPOSE: This study was conducted to investigate the effect of testosterone replacement treatment (TRT) in testosterone deficiency syndrome (TDS) patients with metabolic syndrome. MATERIALS AND METHODS: We reviewed the data of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surgical Treatment of Acute Arterial Occlusion after Applying the Vascular Closure Device for Hemostasis of Femoral Arteriotomy in Vascular Intervention

Yoon JC, Kwon JS, Kim HY, Kang HJ, Yoon DK, Chon SE, Lee JJ, Lee JH, Lee S, Park SG

  • KMID: 1448100
  • J Korean Soc Vasc Surg.
  • 2011 Feb;27(1):27-30.
Vascular intervention via the femoral artery can cause vascular access complications and complications from closure of the arteriotomic incision site such as bleeding, thrombotic complications and vascular trauma. These types...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Initial Biopsy Outcome Prediction in Korean Patients-Comparison of a Noble Web-based Korean Prostate Cancer Risk Calculator versus Prostate-specific Antigen Testing

Park JY, Yoon S, Park MS, Cho DY, Park HS, Moon DG, Yoon DK

We developed and validated a novel Korean prostate cancer risk calculator (KPCRC) for predicting the probability of a positive initial prostate biopsy in a Korean population. Data were collected from...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of the Partial Obstruction Site of the Renal Vein on Testis and Kidney in Rats: Is the Traditional Animal Model Suitable for Varicocele Research?

Ko KW, Kim SW, Moon DG, Kim JJ, Yoon DK, Park JY

  • KMID: 2314620
  • Korean J Urol.
  • 2010 Oct;51(10):733-733.
One of the authors' names was included by mistake. The author list should be corrected as follows. Corrected Author List: Ki Won Ko, Soo Woong Kim, Du Geon Moon, Je Jong Kim,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of the Partial Obstruction Site of the Renal Vein on Testis and Kidney in Rats: Is the Traditional Animal Model Suitable for Varicocele Research?

Ko KW, Chae JY, Kim SW, Moon DG, Kim JJ, Yoon DK, Park JY

PURPOSE: We investigated the influence of the location of the partial renal vein obstruction on the left kidney, the bilateral testes, and cauda epididymal sperm quality and determined whether this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Efficacy of Parenchymal Compression in Open Partial Nephrectomies: A Comparison with Conventional Vascular Clamping

Ko YH, Choi H, Kang SG, Kang SH, Park HS, Cheon J, Lee JG, Kim JJ, Yoon DK

  • KMID: 2314701
  • Korean J Urol.
  • 2010 Jan;51(1):8-14.
PURPOSE: We evaluated the efficacy of parenchymal compression in open partial nephrectomies (OPNs) compared with that of the conventional vascular clamping method. MATERIALS AND METHODS: OPNs were conducted by means...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparison of Outcomes between Transurethral Resection of the Prostate and High Power Potassium-titanyl-phosphate Laser Vaporization of the Prostate

Kang SC, Ham BK, Park SH, Ko KW, Yoon DK, Moon DG

  • KMID: 2298777
  • Korean J Androl.
  • 2009 Apr;27(1):42-48.
PURPOSE: Transurethral resection of the prostate (TURP) is the gold standard for the surgical treatment for benign prostatic hyperplasia (BPH), but the procedure's limitations are its invasiveness and the high...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Risk Factors of the Infectious Complications and Causative Microorganisms after Transrectal Ultrasound-guided Prostate Needle Biopsy

Jang HA, Kang JI, Bae YD, Jin MH, Park JY, Moon DG, Yoon DK, Kim JJ

  • KMID: 2226551
  • Korean J Androl.
  • 2008 Dec;26(4):212-217.
PURPOSE: Transrectal ultrasound-guided prostate needle biopsy (TRUS-PBx) is the standard procedure to diagnose prostate cancer. We evaluated the incidence and risk factors of infectious complications, the species cultured and rates...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Matched-cohort Comparison of Laparoscopic Renal Cryoablation using Ultra-thin Cryoprobes with Open Partial Nephrectomy for the Treatment of Small Renal Cell Carcinoma

Ko YH, Park HS, Moon DG, Lee JG, Kim JJ, Yoon DK, Kang SH, Cheon J

  • KMID: 1972645
  • Cancer Res Treat.
  • 2008 Dec;40(4):184-189.
PURPOSE: To evaluate the feasibility and efficacy of performing laparoscopic renal cryoablation (LRC) for the treatment of RCC, as compared with open partial nephrectomy (OPN), which is the established NSS. MATERIALS...