The effect of thickness of the provisional crown and fixed partial denture materials on the translucency and masking effect

Jae HJ, Kim SH, Lee SH, Pae AR

  • KMID: 2195627
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):724-734.
STATEMENT OF PROBLEM: Translucency and masking effect of provisional crown and fixed partial denture materials is an important esthetic consideration. But, provisional resin materials differ substantially in their ability to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A two-year study of implant retained overdentures in the treatment of totally edentulous jaws

Kwon HB, Kim EH, Lee SH

  • KMID: 2195631
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):760-768.
STATEMENT OF PROBLEM: Conventional denture treatment for totally edentulous patients is associated with a variety of functional and psychosocial problems. The placement of implants in the anterior region of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface microgrooves of thirty micrometers in width on titanium substrata enhance proliferation and alter gene expression of cultured human gingival fibroblasts

Lee SW, Kim SY, Lee KW

  • KMID: 2195634
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):787-794.
STATEMENT OF PROBLEM: Surface microgrooves on Ti substrata have been shown to alter the expression of genes responsible for various biological activities of cultured fibroblasts. However, their effect on enhancing...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Biomechanics of abutments supporting removable partial dentures underunilateral loading

Kim SK, Heo SJ, Koak JY, Lee JT, Roh HK, Kim HJ, Lee SH, Lee JH

  • KMID: 2195630
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):753-759.
STATEMENT OF PROBLEM: In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress under unilateral loading...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Detorque force of TiN-coated abutment screw with various coating thickness after repeated closing and opening

Kim HS, Kim HJ, Chung CH

  • KMID: 2195632
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):769-779.
STATEMENT OF PROBLEM: When TiN coating is applied to the abutment screw, occurrence of greater preload and prevention of the screw loosening could be expected due to decrease of frictional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparative study of the 1-piece and 2-piece conical abutment joint: the strength and the fatigue resistance

Kwon TK, Yang JH, Kim SH, Han JS, Lee JB

  • KMID: 2195633
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):780-786.
STATEMENT OF PROBLEM: The performance and maintenance of implant-supported prostheses are primarily dependent upon load transmission both at the bone-to-implant interface and within the implant-abutment-prosthesis complex. The design of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparative study of shear bond strength between cp-Ti / Co-Cr alloy and composite resins

Yoon SH, Pae A, Lee SH, Lee H

  • KMID: 2195636
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):805-814.
STATEMENT OF PROBLEM: Composite resin-veneered metal restorations can be used as an alternative to porcelain-fused-metal restorations. But, because of the relatively low bond strength of veneering composite to metal framework,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The effect of monomer to powder ratio on polymerization shrinkage-strain kinetics of polymer-based provisional crown and fixed partial denture materials

Kim SH

  • KMID: 2195628
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):735-742.
STATEMENT OF PROBLEM: Although a number of previous investigations have been carried out on the polymerization shrinkage-strain kinetics of provisional crown and fixed partial denture (FPD) materials, the effect of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface analyses of titanium substrate modified by anodization and nanoscale Ca-P deposition

Lee JM, Kim CW, Lim YJ, Kim MJ

  • KMID: 2195635
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):795-804.
STATEMENT OF PROBLEM: Nano-scale calcium-phosphate coating on the anodizing titanium surface using ion beam-assisted deposition (IBAD) has been recently introduced to improve the early osseointegration. However, not much is known...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of surface treatment methods on the shear bond strength of resin cement to zirconia ceramic

Lee HJ, Ryu JJ, Shin SW, Suh KW

  • KMID: 2195629
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):743-752.
STATEMENT OF PROBLEM: The aims of the study were to evaluate the effect of current surface conditioning methods on the bond strength of a resin composite luting cement bonded to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A strain gauge analysis of implant-supported cantilevered fixed prosthesis under distal static load

Sohn BS, Heo SJ, Chang IT, Koak JY, Kim SK

  • KMID: 2195626
  • J Korean Acad Prosthodont.
  • 2007 Dec;45(6):717-723.
STATEMENT OF PROBLEM: Unreasonable distal cantilevered implant-supported prosthesis can mask functional problems of reconstruction temporarily, but it can cause serious strain and stress around its supported implant and surrounding alveolar...