Effect of implant designs on insertion torque and implant stability quotient (ISQ) value

Piao CM, Heo SJ, Koak JY, Kim SK, Han CH, Fang XH

  • KMID: 2000683
  • J Korean Acad Prosthodont.
  • 2006 Jun;44(3):325-332.
Statement of problem. Primary implant stability has long been identified as a prerequisite to achieve osseointegration. So the application of a simple, clinically applicable noninvasive test to assess implant...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A study on the correlation between implant stability values and initial insertion torque

Lee JH, Yang JH

  • KMID: 2000682
  • J Korean Acad Prosthodont.
  • 2006 Jun;44(3):314-324.
Statement of problem. Osseointegration is important mechanism of dental implant but it is not easy to evaluate. Indirect measurement is non-invasive and clinically applicable but they need more study...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Marginal fit of the digident CAD/CAM zirconia ceramic crowns

Kim YS, Yang JH

  • KMID: 2000679
  • J Korean Acad Prosthodont.
  • 2006 Jun;44(3):275-283.
Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. However most of the statistical inferences are not definite...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A comparative study between degree of conversion and flexural strength of composite resins

Lee SH, Pae AR, Kim SH

  • KMID: 2000684
  • J Korean Acad Prosthodont.
  • 2006 Jun;44(3):333-342.
Statement of problem. Although many studies have been carried out to investigate the correlation between the degree of conversion and the flexural strength of composite resins, there is minimal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface characteristics of anodic oxidized titanium according to the pore size

Ha HS, Kim CW, Lim YJ, Kim MJ

  • KMID: 2000685
  • J Korean Acad Prosthodont.
  • 2006 Jun;44(3):343-355.
Statement of problem. The success of osseointegration can be enhanced with an implant that has improved surface characteristics. Anodic oxidation is one of the surface modifying method to achieve...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Application of finite element analysis to evaluate implant fractures

Kim YS, Kim CW, Lim YJ, Kim MJ

  • KMID: 2000681
  • J Korean Acad Prosthodont.
  • 2006 Jun;44(3):295-313.
Statement of problem. Higher fracture rates were reported for Branemark implants placed in the maxilla and for 3.75 mm diameter implants installed in the posterior region. Purpose. The purpose of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Photocatalytic antifungal activity against candida albicans by TiO2 coated acrylic resin denture base

Yang JY, Kim HJ, Chung CH

  • KMID: 2000680
  • J Korean Acad Prosthodont.
  • 2006 Jun;44(3):284-294.
Statement of problem. Proliferation of Candida albicans is primarily within the plaque on the fitting surface of the denture rather than on the inflamed mucosa. Consequently, the treatment of...