Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

8 results
Display

Case Reports On The Magnetic Retained Overdentures

Vang MS, Choi CH, Kim YY

  • KMID: 2118663
  • J Korean Acad Prosthodont.
  • 2002 Feb;40(1):88-97.
The purpose of this study was to evaluate a cases which was treated with magnetic attachments on the patients in edentulous mandible and maxilla.Author made magnetic overdenture for two patients...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Marginal Adaptation Of The Conical Inner Crown Fabricated With Cad/cam

Kim IS, Kang DW

  • KMID: 2118658
  • J Korean Acad Prosthodont.
  • 2002 Feb;40(1):30-41.
This study was to evaluate the fabrication method and marginal adaptation of the conical inner crown fabricated with CAD/CAM.The informations on abutment teeth were transferred to a computer with a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Comparative Study on the Accuracy of Master Casts by Implant Impression Techniques

Rhyu SM, Cho IH, Lim HS, Lim JH

  • KMID: 2118657
  • J Korean Acad Prosthodont.
  • 2002 Feb;40(1):18-29.
As the inaccuracy which was made in implant impression prevented passive fit,it needed to solder the sectioned framework at several locations to correct the inaccuracy. Many clinicians have suggested impression...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Study On The Color Stability Of Composite Resin

Kim HJ, Kim KJ, Cho HW, Jin TH

  • KMID: 2118662
  • J Korean Acad Prosthodont.
  • 2002 Feb;40(1):79-87.
The purpose of this study was to investigate the color stability of composite resins used widely as esthetic restorative material.Surefil(Dentsply,U.S.A.),Esthet X(Dentsply,U.S.A.),Filtek P60(3M,U.S.A.),Filtek Z250(3M,U.S.A.),Synergy Compact(Coltene,Switzerland),and Synergy Duo(Coltene,Switzerland)were chosen for this study.Thirty...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study on the Bond Strength of Reline Resin to Pressure Injection Type Thermoplastic Denture Base Resin

Moon TS, Jeong CM, Jeon YC, Lim JS

  • KMID: 2118659
  • J Korean Acad Prosthodont.
  • 2002 Feb;40(1):42-52.
The purpose of this study was to evaluate the bond strength of reline resin to pressure injection type thermoplastic denture base resin.The denture base resins used in this study were...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Stress Analysis of Supporting Tissue and Implant According to Crown Restorative Materials and Type of Implant

Choi CH, Oh JS, Vang MS

  • KMID: 2118660
  • J Korean Acad Prosthodont.
  • 2002 Feb;40(1):53-67.
This study was aimed to analyze the stress distribution of implant and supporting tissue in single tooth implant restoration using Bra nemark system(Nobel Biocare,Gothenberg,Sweden) and Bicon system(Bicon Dental Implants,Boston,MA).Two dimensional...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mechanical Properties of Quartz Fiber Post

Lee YS, Kang IJ

  • KMID: 2118661
  • J Korean Acad Prosthodont.
  • 2002 Feb;40(1):68-78.
The post core system has been used for reconstructon of severely damaged crown by caries or trauma.But problems such as crown exfoliation,post core fracture and root fracture have been reported....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study On The Temperature Changes Of Bone Tissues During Implant Site Preparation

Kim PI, Kim YS, Jang KS, Kim CW

  • KMID: 2118656
  • J Korean Acad Prosthodont.
  • 2002 Feb;40(1):1-17.
The purpose of this study is to examine the possibility of thermal injury to bone tissues during an implant site preparation under the same condition as a typical clinical practice...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr