Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

80 results
Display

Risk Factors of Allogenous Bone Graft Collapse in Two-Level Anterior Cervical Discectomy and Fusion

Woo JB, Son DW, Lee SH, Lee JS, Lee SW, Song GS

OBJECTIVE: Anterior cervical discectomy and fusion (ACDF) is commonly used surgical procedure for cervical degenerative disease. Among the various intervertebral spacers, the use of allografts is increasing due to its...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Monitoring osseointegrated prosthesis loosening and fracture using electrical capacitance tomography

Gupta S, Loh KJ

A noncontact, noninvasive, electrical permittivity imaging technique is proposed for monitoring loosening of osseointegrated prostheses and bone fracture. The proposed method utilizes electrical capacitance tomography (ECT), which employs a set...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The vanishing stent: Repeated fracture and dissolution of nitinol gastric stents in a long term cancer survivor

Randle Lunt C, Najaran P, Edwards DE, Bell JK, Mullan D, Laasch HU

Nitinol self expandable metal stents are increasingly utilised for malignant obstruction in the proximal gastrointestinal tract. We describe a case in which repeated fracture of proximal duodenal stents with dissolution...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Acetabular Cup Revision Arthroplasty Using Morselized Impaction Allograft

Lee JM, Kim TH

The rate of acetabular cup revision arthroplasty is gradually rising along with an increased risk of osteolysis and prosthesis loosening over time and an increase in life expectancy. The goals...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Is Immediate Postoperative Mechanical Axis Associated with the Revision Rate of Primary Total Knee Arthroplasty? A 10-Year Follow-up Study

Park JK, Seon JK, Cho KJ, Lee NH, Song EK

BACKGROUND: Achieving neutral limb alignment during total knee arthroplasty (TKA) has been considered an important determinant in the long-term prosthesis survival. The purpose of this study was to evaluate the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Results of Total Hip Arthroplasty with 36-mm Metallic Femoral Heads on 1st Generation Highly Cross Linked Polyethylene as a Bearing Surface in Less than Forty Year-old Patients: Minimum Ten-year Results

Choi WK, Kim JJ, Cho MR

PURPOSE: We evaluated long-term clinical and radiographic results in patients underwent primary total hip arthroplasty (THA) using 36-mm metallic femoral head and 1st generation highly cross-linked polyethylene among patients aged...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Rare Case of Intra-Articular Displacement of EndoButton Following Anterior Cruciate Ligament Reconstruction

Ho SW, Lee KT

The EndoButton is a commonly used device for femoral fixation of anterior cruciate ligament grafts. Complications from its usage remain rare. Incorrect femoral tunnel placement may increase the risk of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Biomechanical Comparison Study of Three Fixation Methods for Proximal Chevron Osteotomy of the First Metatarsal in Hallux Valgus

Kim JS, Cho HK, Young KW, Kim JS, Lee KT

BACKGROUND: Fixation of proximal chevron metatarsal osteotomy has been accomplished using K-wires traditionally and with a locking plate recently. However, both methods have many disadvantages. Hence, we developed an intramedullary...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Lower T1 Slope as a Predictor of Subsidence in Anterior Cervical Discectomy and Fusion with Stand-Alone Cages

Lee SH, Lee JS, Sung SK, Son DW, Lee SW, Song GS

OBJECTIVE: Preoperative parameters including the T1 slope (T1S) and C2–C7 sagittal vertical axis (SVA) have been recognized as predictors of kyphosis after laminoplasty, which is accompanied by posterior neck muscle...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of Uncinate Process Resection on Subsidence Following Anterior Cervical Discectomy and Fusion

Lee SH, Lee JS, Sung SK, Son DW, Lee SW, Song GS

OBJECTIVE: Subsidence is a frequent complication of anterior cervical discectomy and fusion. Postoperative segmental micro-motion, thought to be a causative factor of subsidence, has been speculated to increase with uncinate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Novel Partially Covered Self-Expandable Metallic Stent with Proximal Flare in Patients with Malignant Gastric Outlet Obstruction

Takahara N, Isayama H, Nakai Y, Yoshida S, Saito T, Mizuno S, Yagioka H, Kogure H, Togawa O, Matsubara , Ito Y, Yamamoto N, Tada M, Koike K

BACKGROUND/AIMS: Endoscopic placement of self-expandable metal stents (SEMSs) has emerged as a palliative treatment for malignant gastric outlet obstruction (GOO). Although covered SEMSs can prevent tumor ingrowth, frequent migration of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Partially Covered Metal Stents May Not Prolong Stent Patency Compared to Uncovered Stents in Unresectable Malignant Distal Biliary Obstruction

Kim JY, Ko GB, Lee TH, Park SH, Lee YN, Cho YS, Jung Y, Chung IK, Choi HJ, Cha SW, Moon JH, Cho YD, Kim SJ

BACKGROUND/AIMS: Controversy still exists regarding the benefits of covered self-expandable metal stents (SEMSs) compared to uncovered SEMSs. We aimed to compare the patency and stent-related adverse events of partially covered...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Causes of Aseptic Persistent Pain after Total Knee Arthroplasty

Lim HA, Song EK, Seon JK, Park KS, Shin YJ, Yang HY

BACKGROUND: Persistent pain after total knee arthroplasty (TKA) is dissatisfying to the patient and frustrating to the surgeon. The purpose of this study is to evaluate the aseptic causes and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cementless Total Hip Arthroplasty Involving Trochanteric Osteotomy without Subtrochanteric Shortening for High Hip Dislocation

Lee SJ, Yoo JJ, Kim HJ

BACKGROUND: Total hip arthroplasty with subtrochanteric shortening osteotomy is widely performed for high hip dislocation. However, suboptimal leg length discrepancy correction and nonunion of the osteotomy site remain concerns. Although...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Factors That Affect Stent-Related Complications in Patients with Malignant Obstruction of the Esophagus or Gastric Cardia

Iwasaki H, Mizushima , Suzuki Y, Fukusada S, Kachi K, Ozeki T, Anbe K, Tsukamoto , Okumura F, Joh T, Sano H

BACKGROUND/AIMS: Self-expandable metallic stent (SEMS) placement is effective for dysphagia that results from malignant obstruction of the esophagus or gastric cardia; however, stent-related complications may be life-threatening. Thus, the goal...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Stability of the prosthetic screws of three types of craniofacial prostheses retention systems

Lanata-Flores AG, Sigua-Rodriguez EA, Goulart DR, Bomfim-Azevedo VL, Olate S, de Albergaria-Barbosa JR

OBJECTIVES: This study aimed to evaluate the stability of prosthetic screws from three types of craniofacial prostheses retention systems (bar-clip, ball/O-ring, and magnet) when submitted to mechanical cycling. MATERIALS AND METHODS:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Pararectal Migration of a Malleable Rod: An Unusual Late Complication

Kucukturkmen I, Topcu YK, Degirmenci T, Aydogdu O, Bozkurt IH, Yarimoglu , Polat S

A 75-year-old male had failed to respond conservative therapy for erectile dysfunction and had undergone insertion of a malleable penile prosthesis in 1995. Twenty years after the initial implant he...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
New Technique for Removal of the Ulnar Intramedullary Nail Failed to Remove: Broken Assembly Piece in the Nail

Yi JW, Oh BH, Kim SB, Heo YM, Kim TG, Kim DH, Jung YS

Methods about removal of intramedullary nail in complicated cases were reported in some literatures but there are no reports about nail removal in the ulna. The authors would like to...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

Lee JH, Lee JB, Kim MY, Yoon JH, Choi SH, Kim YT

PURPOSE: The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Optic Fracture of the Preloaded Intraocular Lens during Insertion

Lee JY, Kim JY

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2023 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr