Commissioning and Validation of a Dedicated Scanning Nozzle at Samsung Proton Therapy Center

Chung K, Han Y, Ahn SH, Kim JS, Nonaka H

In this study, we present the commissioning and validation results of a dedicated scanning nozzle. The dedicated scanning nozzle is installed in one of the two gantry treatment rooms at...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluations of the Space Dose and Dose Reductions in Patients and Practitioners by Using the C-arm X-ray Tube Shielding Devices Developed in Our Laboratory

Kim JS, Kim SH, Lee BH, Kwon SI, Jung H, Hoe SW, Son JH, Kang BS

The present study used a digital angiography x-ray device to measure the space dose and exposure dose of patients and practitioners using x-ray tube shielding devices developed in our laboratory....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of Treatment and Delay Times by Disease Site and Delivery Technique at Samsung Medical Center: Proton Therapy Center

Jo K, Ahn SH, Chung K, Cho S, Shin E, Hong CS, Park S, Kim DH, Lee B, Lee WJ, Seo SK, Jang JY, Choi DH, Lim DH, Han Y

We have treated various disease sites using wobbling and scanning proton therapy techniques since December 2015 at the Samsung Medical Center. In this study, we analyze the treatment time for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Conceptual Study of Brain Dedicated PET Improving Sensitivity

Shin HB, Choi Y, Huh Y, Jung JH, Suh TS

The purpose of this study is to propose a novel high sensitivity neuro-PET design. The improvement of sensitivity in neuro-PET is important because it can reduce scan time and/or radiation...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development Treatment Planning System Based on Monte-Carlo Simulation for Boron Neutron Capture Therapy

Kim MS, Kubo K, Monzen H, Yoon DK, Shin HB, Kim S, Suh TS

The purpose of this study is to develop the treatment planning system (TPS) based on Monte-Carlo simulation for BNCT. In this paper, we will propose a method for dose estimation...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
An Empirical Approach to Dosimetric Effect of Carbon Fiber Couch for Flattening Filter Free Beam of Elekta LINAC

Ahn S, Park K, Kim J, Lee H, Yoon J, Lee E, Park S, Park J, Kim J, Keum KC

Generally, it is recommended that the dosimetric effect of carbon fiber couch should be considered especially for an intensity-modulated therapy with a large portion of monitor units from posterior angles....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility Study of a Custom-made Film for End-to-End Quality Assurance Test of Robotic Intensity Modulated Radiation Therapy System

Kim J, Park K, Yoon J, Lee E, Cho S, Ahn S, Park J, Choi W, Lee H

This paper aims to verify the clinical feasibility of a custom-made film created by a laser cutting tool for End-to-End (E2E) quality assurance in robotic intensity modulated radiation therapy system....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of Target Angle and Thickness on the Heel Effect and X-ray Intensity Characteristics for 70 kV X-ray Tube Target

Kim G, Lee R

To investigate the optimum x-ray tube design for the dental radiology, factors affecting x-ray beam characteristics such as tungsten target thickness and anode angle were evaluated. Another goal of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility Study of Source Position Verification in HDR Brachytherapy Using Scintillating Fiber

Moon SY, Jeong E, Lim YK, Chung WK, Huh HD, Kim DW, Yoon M

The position verification of the radiation source utilized in brachytherapy forms a critical factor in determining the therapeutic efficiency. Currently, films are used to verify the source position; however, this...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Customized 3D Printed Bolus for Breast Reconstruction for Modified Radical Mastectomy (MRM)

Ha JS, Jung JH, Kim MJ, Jeon MJ, Jang WS, Cho YJ, Lee IJ, Kim JW, Suh TS

We aim to develop the breast bolus by using a 3D printer to minimize the air-gap, and compare it to commercial bolus used for patients undergoing reconstruction in breast cancer....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Temperature Distribution in Agar Phantom and Gel Bolus Phantom by Radiofrequency Hyperthermia

Jung DK, Kim SK, Lee JH, Youn SM, Kim HD, Oh SA, Park JW, Yea JW

The usefulness of Gel Bolus phantom was investigated by comparing the temperature distribution characteristic of the agar phantom produced to investigate the dose distribution characteristic of radiofrequency hyperthermia device with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Two Different Immobilization Devices for Pelvic Region Radiotherapy in Tomotherapy

Kim DG, Jung JJ, Cho KH, Ryu MR, Moon SK, Bae SH, Ahn JO, Jung JH

The purpose of this study was to compare the patient setup errors of two different immobilization devices (Feet Fix: FF and Leg Fix: LF) for pelvic region radiotherapy in Tomotherapy....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Dosimetric Validation of the Acuros XB Advanced Dose Calculation Algorithm for Volumetric Modulated Arc Therapy Plans

Park SY, Park JM, Choi CH, Chun M, Kim JI

Acuros XB advanced dose calculation algorithm (AXB, Varian Medical Systems, Palo Alto, CA) has been released recently and provided the advantages of speed and accuracy for dose calculation. For clinical...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Analysis of Physical Properties for Various Compositions of Reusable LMG and LCV Micelle Gel

Kang JM, Lee DH, Cho YR, Hwang SB, Ji YH, Ahn SH, Keum KC, Lee RN, Cho SJ, Noh I

In this study, we evaluated the reusable leuco malachite green (LMG) micelle gel properties dependent on various components of chemical concentration and compared with leuco crystal violet (LCV). The gels...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluating Correlation between Geometrical Relationship and Dose Difference Caused by Respiratory Motion Using Statistical Analysis

Shin DS, Kang SH, Kim DS, Kim TH, Kim KH, Cho MS, Noh YY, Yoon DK, Suh TS

Dose differences between three-dimensional (3D) and four-dimensional (4D) doses could be varied according to the geometrical relationship between a planning target volume (PTV) and an organ at risk (OAR). The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close