Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

8 results
Display

A Case of Pedunculated Localized Nodular Synovitis of the Knee: MR Imaging Findings

Lee JH, Lee JY, Suh KJ

  • KMID: 1511400
  • J Korean Soc Magn Reson Med.
  • 2007 Jun;11(1):54-57.
Localized nodular synovitis of the knee joint is a rare benign tumorous condition, and should be differentially diagnosed with pigmented villonodular synovitis. We report a case of localized nodular synovitis...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Magnetic Resonance Elastography

Kim DH, Yang JW, Kim MJ

  • KMID: 1511394
  • J Korean Soc Magn Reson Med.
  • 2007 Jun;11(1):10-19.
Conventional MRI methods using T1-, T2-, diffusion-, perfusion-weighting, and functional imaging rely on characterizing the physical and functional properties of the tissue. In this review, we introduce an imaging modality...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Osteosarcoma Arising in a Polyostotic Fibrous Dysplasia: A Case Report

Suh KJ

  • KMID: 1511399
  • J Korean Soc Magn Reson Med.
  • 2007 Jun;11(1):49-53.
Fibrous dysplasia is a skeletal developmental anomaly of the bone-forming mesenchyme that manifests as a defect in osteoblastic differentiation and maturation. It is a nonhereditary disorder of unknown cause. In...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cardiac MRI

Lee J

  • KMID: 1511393
  • J Korean Soc Magn Reson Med.
  • 2007 Jun;11(1):1-9.
The obstacles for cardiac imaging are motion artifacts due to cardiac motion, respiration, and blood flow, and low signal due to small tissue volume of heart. To overcome these obstacles,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of Solenoid RF Coil for Animal Imaging in 3T High Magnetic Field MRI

Lee HS, Woo DC, Min KH, Kim YK, Lee HK, Choe BY

  • KMID: 1511395
  • J Korean Soc Magn Reson Med.
  • 2007 Jun;11(1):20-26.
PURPOSE: The purpose of the present study was to develop and optimize solenoid coil for animal- model in 3 T MRI system and investigate and compare with the birdcage coil...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Usefulness of the 3-D Overlapped Reconstruction MR Angiographic Technique in Patients with Hemifacial Spasm - A Preliminary Study

Lee YM, Lim MK, Park SW, Pyun HW, Yoon MK, Kim EY, Suh CH

  • KMID: 1511397
  • J Korean Soc Magn Reson Med.
  • 2007 Jun;11(1):33-38.
PURPOSE: To investigate the applicability of the new three-dimensional overlapped reconstruction MR angiography (3-D ORMRA) technique in patients with hemifacial spasm and to compare the new 3-D reconstruction images with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Mucoid Degeneration of Anterior Cruciate Ligament: Correlation between MR Imaging and Pathologic Findings in Patients with Osteoarthritis of the Knee

Ryu JA, Liew H, Lee SH, Kim SM, Shin MJ, Shin HJ, Cho KJ, Cho WS, Kang CH, Lee MH, Kim MS, Park NH, Lee EJ, Park SI, Park CS

  • KMID: 1511396
  • J Korean Soc Magn Reson Med.
  • 2007 Jun;11(1):27-32.
PURPOSE: To evaluate the mucoid degeneration (MD) of the anterior cruciate ligament (ACL) of the knee by correlation of MRI findings with pathology, in the patients with osteoarthritis (OA). MATERIALS AND...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Comparison between Single Shot Turbo Spin Echo and B-FFE (Balanced Turbo Field-echo) in the Differentiation of Focal Liver Lesions

Kim YC, Kim MJ, Cha SW, Chung YE, Han KH, Choi JS

  • KMID: 1511398
  • J Korean Soc Magn Reson Med.
  • 2007 Jun;11(1):39-48.
PURPOSE: To determine the diagnostic accuracy of four different sequences : moderately T2 weighted, two heavily T2-weighted single shot turbo spin-echo sequence and breath-hold axial-2D balanced turbo field-echo sequence(bFFE) for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr