Annual Report on External Quality Assessment in Urinalysis in Korea (1998)

Kim KD, Koo SH, Kim EC, Kim JM, Kim CH, Kim JQ, Kim HJ, Moon DS, Min WK, Yoon K, Cheung DJ, Cho SS

  • KMID: 2055384
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):81-93.
One external quality assessment trial which composed of five control materials (four chemical materials, one parasite material) for interlaboratory quality control assessment in urinalysis and parasitology were performed with 324...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on External Quality Assessment in Immunoassay in Korea (1998)

Kwon OH, Lim HS, Kim HS, Kim DA, Kim YK, Kim JQ, Shin S, Jang YS, Cho HS

  • KMID: 2055386
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):107-128.
This is the report of fourth-year trial of external quality assessment for immunoassay in Korea. We attempted one trials of external quality assessments in 1998. A total of 7 specimens...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on External Quality Assessment in Hematology in Korea (1998)

Lee WS, Rho MH, Do WS, Park CJ, Song KS, Yang DU, Yoon HD, Yoon HS, Lee KS, Chung W, Cho HI, Chi HS, Choi JT, Han KJ

  • KMID: 2055382
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):23-36.
Four trials of external quality assessment in diagnostic hematology were performed in 1998 with 350 participating laboratories in Korea. We performed quality assessment for white blood cell count, hemoglobin, red...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Study on Home Made Lyophilized Plasma for Quality Control

Lee WS

  • KMID: 2055397
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):209-215.
BACKGROUND: The use of frozen plasma is possible for internal quality control. Lyophilized plasma is expensive and is currently imported from abroad. The aim of present study was to prepare...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on External Quality Assessment in Immunoserology in Korea (1998)

Kim JR, Kim DJ, Kim MJ, Kim TY, Kim EJ, Kim HS, Moon JS, Park MH, Park AJ, Baek DH, Son HC, Lee KS, Lee HR, Jang YW, Cha YJ

  • KMID: 2055383
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):37-80.
The followings are the results for quality assessment in immunoserology for 1998: 1. Evaluation of external quality assessment was done in 2 trials, the first was participated by 81.0% and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Lyophilized Quality Control Material for Clinical Chemistry and Coagulation

Park H, Lee DH, Yoon YM, Jung HJ, Song J, Park SS, Kim JQ

  • KMID: 2055392
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):175-180.
BACKGROUND: Quality control material is essential reagent/material for maintaining the precision of clinical laboratory analysis. The manufacturing effort or study of the quality control material in Korea is in its...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on External Quality Assessment in Diagnostic Gentics in Korea (1998)

Cho HC, Kim SH, park SS, Yoon HR, Kim EC, Park SJ, Park JW, Seo SP, Song KS, Lee YK, Jeon HJ, Joo SI, Chi HS

  • KMID: 2055389
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):147-158.
The importance of quality control for dramatically growing genetic tests continues to be emphasized with increasing clinical demands. Diagnostic genetics subcommittee of KSQACP performed one proficiency trial for molecular genetic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on External Quality Assessment in Inborn Error of Metabolism in Korea (1998)

Kim JW, Kwon KC, Kim CH, Min WK, Park SY, Baik BY, Song JH, Lee SY, Lee EH, Choi TY

  • KMID: 2055388
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):143-146.
Second trial of external quality assessment for inborn error of metabolism was performed in 1998. A total six specimens for neonatal screening test were distributed to 57 laboratories with a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on External Quality Assessment in Therapeutic Drug Monitoring in Korea (1998)

Kim JQ, Kwon OH, Kwon HJ, Kim YK, Kim JW, Kim TJ, Song J, Lee KN, Jung YS

  • KMID: 2055387
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):129-141.
Two trials of external quality assessment for therapeutic drug monitoring (TDM) were performed in 1998. A total of two specimens covering 26 test items were distributed. First specimen was distributed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on External Quality Assessment in Clinical Chemistry in Korea (1998)

Min WK, Kim YK, Kwon OH, Kim KD, Kim SS, Kim JW, Kim JQ, Kim TJ, Park MR, Ahn KS, Jung NS, Jung HS, Hong KS

  • KMID: 2055380
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):1-11.
Ten trials of external quality assessment for clinical chemistry in general chemistry and blood gas were performed in 1998. All the control materials were sent in specifically-made plastic box at...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on External Quality Assessment of Clinical Microbiology Laboratory in Korea (1998)

Kim EC, Kang JO, Kim MJ, Kim BC, Kim SI, Lee KW, Lee DH, Lee JH, Lee NY, Lee CK, Shin CH, Chang CH, Choi HS

  • KMID: 2055381
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):13-22.
Two trials of external quality assessment for clinical microbiology laboratory were performed in 1998. A total of ten specimens were distributed. Five specimens were distributed to 430 laboratories with 193...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Annual Report on External Quality Assessment in Blood Bank Tests in Korea (1998)

Kim DW, Kwon SW, Kim WB, Kim HO, Oh YC, Cha YJ, Han KS, Han BN, Choi BR, Ryu KH, Kwon KC, Ryang DW, Hwang YS

  • KMID: 2055385
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):95-105.
Surveys for external quality assessment in blood bank tests were carried out in 1998. The response rate was 90.6% for 1st trial, 80.6% for 2nd trial, and 79.1% for 3rd...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Diagnostic Efficacy of Rapid Whole-Blood Assay for D-dimer in Patients with Disseminated Intravascular Coagulation

Kim HK, Song KS, Park Q

  • KMID: 2055398
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):217-221.
BACKGROUND: Many laboratories are using D-dimer tests for the investigation of suspected disseminated intravascular coagulation (DIC) which need early diagnosis and treatments. Recently, SimpliRED D-dimer assay (AGEN Biomedical Ltd, Australia)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
HLA-DR Typing with PEL-FREEZ(R) DR4 TEST-SSP UNITRAY(TM)

Choi SJ, Won CY, Oh HB

  • KMID: 2055401
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):237-241.
BACKGROUND: PEL-FREEZ(R) DR4 TEST-SSP UNITRAY(TM) (PEL-FREEZ) was recently introduced in Korea, which utilized the technique of sequence specific primer-polymerase chain reaction for HLA-DR typing. METHODS: The performance of PEL-FREEZ was compared...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of the TEST 1 for Measuring Erythrocyte Sedimentation Rate

Shin KS, Kim JS, Son BR

  • KMID: 2055399
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):223-228.
BACKGROUND: Although the erythrocyte sedimentation rate (ESR) test is a diagnostically nonspecific and insensitive laboratory test, it is still considered a reliable indirect indicator of the acute or chronic inflammatory...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Direct Determination of Low-Density Lipoprotein Cholesterol using Homogeneous Method

Lee MK, Lee DS, Park AJ

  • KMID: 2055390
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):159-165.
BACKGROUND: Most clinical laboratories use the Friedewald equation for estimating low-density lipoprotein cholesterol (FLDL-C). However, this equation is invalid when fasting triglyceride (TG) levels are >400 mg/dL. These limitation creates...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of the Home-Made Panel Tray for Panel Reactive Antibody Test

Kim SR, Lee SH, Lee JS, Cho HR, Kim KY, Cho YS, Park RJ, Son HC

  • KMID: 2055400
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):229-235.
BACKGROUND: The panel reactive antibody (PRA) test is critical for predicting the probability of cadaver transplantation to possible organ recipients. In Korea, only a few institutions are performing the PRA...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Penicillin Susceptibility Screening of Streptococcus pneumoniae by Disk Diffusion with Blood Agar Plate; Is It Appropriate

Kim SR, Chang CL, Jeong J, Shin JH, Kim HH, Lee SH, Son HC, Kim SH

  • KMID: 2055395
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):195-200.
BACKGROUND: Blood agar plates (BAP) have been used in penicillin susceptibility tests using the disk diffusion method with 1 microgram oxacillin disk in the country's laboratories, despite the recommendation of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Performance Analysis of ACS : Centaur(TM) Immunoassay System

Woo HY, Song SM, Lee SY, Kim JW

  • KMID: 2055394
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):187-193.
BACKGROUND: As the number of the analytes which are tested with immunologic methods has been increased, the requirement for immunoassay systems with high-capacity and increased efficiency has been also increased....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Use of Serum Separation Tube (SST) for Hormone Assay by Chemiluminescence Immunoassay

Hong SB, Kim HS, Lee DH

  • KMID: 2055393
  • J Clin Pathol Qual Control.
  • 1999 Jun;21(1):181-186.
BACKGROUND: Utilization of serum separation tubes (SST) can shorten sample processing time and minimize the chance of exposure to potentially hazardous aerosols compared to the use of plain tubes. However,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top