Skip Navigation
Skip to contents
Filter

ARTICLE TYPE

PUBLICATION DATE

10 results
Display

The effect of mechanical or electrical stimulation on apnea length in mice

Jawde SB, Scheuermann A, Bartolák-Suki E, Suki B

  • Biomed Eng Lett.
  • 2018 Aug;8(3):329-335.
  • doi: 10.1007/s13534-018-0076-1
Premature birth is a leading cause of infant mortality which is often attributed to irregular breathing and apnea of prematurity. A common treatment for apnea is caffeine to stimulate the...
Automatic disease stage classification of glioblastoma multiforme histopathological images using deep convolutional neural network

Yonekura A, Kawanaka H, Surya Prasath VB, Aronow BJ, Takase H

  • Biomed Eng Lett.
  • 2018 Aug;8(3):321-327.
  • doi: 10.1007/s13534-018-0077-0
In the field of computational histopathology, computer-assisted diagnosis systems are important in obtaining patient-specific diagnosis for various diseases and help precision medicine. Therefore, many studies on automatic analysis methods for...
Characteristics of the pulsating jet flow through a dynamic glottal model with a lens-like constriction

Mattheus W, Brücker C

  • Biomed Eng Lett.
  • 2018 Aug;8(3):309-320.
  • doi: 10.1007/s13534-018-0075-2
A computational study of the pulsating jet in a squared channel with a dynamic glottal-shaped constriction is presented. It follows the model experiments of Triep and Brücker (J Acoust Soc...
A novel hinged ankle foot orthosis for gait performance in chronic hemiplegic stroke survivors: a feasibility study

Lee SH, Choi C, Lee D, Lee S, Song S, Pyo S, Hong S, Lee G

  • Biomed Eng Lett.
  • 2018 Aug;8(3):301-308.
  • doi: 10.1007/s13534-018-0074-3
Stroke survivors with gait disturbances may use ankle foot orthoses (AFOs). However, most AFOs come in one-piece styles, which make it difficult for spasticity-affected stroke survivors to don. AFOs are...
Monitoring osseointegrated prosthesis loosening and fracture using electrical capacitance tomography

Gupta S, Loh KJ

  • Biomed Eng Lett.
  • 2018 Aug;8(3):291-300.
  • doi: 10.1007/s13534-018-0073-4
A noncontact, noninvasive, electrical permittivity imaging technique is proposed for monitoring loosening of osseointegrated prostheses and bone fracture. The proposed method utilizes electrical capacitance tomography (ECT), which employs a set...
Validation of foot pitch angle estimation using inertial measurement unit against marker-based optical 3D motion capture system

Sharif Bidabadi S, Murray I, Lee GY

  • Biomed Eng Lett.
  • 2018 Aug;8(3):283-290.
  • doi: 10.1007/s13534-018-0072-5
Gait analysis is relevant to a broad range of clinical applications in areas of orthopedics, neurosurgery, rehabilitation and the sports medicine. There are various methods available for capturing and analyzing...
Electrodeless conductivity tensor imaging (CTI) using MRI: basic theory and animal experiments

Sajib SZ, Kwon OI, Kim HJ, Woo EJ

  • Biomed Eng Lett.
  • 2018 Aug;8(3):273-282.
  • doi: 10.1007/s13534-018-0066-3
The electrical conductivity is a passive material property primarily determined by concentrations of charge carriers and their mobility. The macroscopic conductivity of a biological tissue at low frequency may exhibit...
Mechanical properties and cytotoxicity of PLA/PCL films

Jeong H, Rho J, Shin JY, Lee DY, Hwang T, Kim KJ

  • Biomed Eng Lett.
  • 2018 Aug;8(3):267-272.
  • doi: 10.1007/s13534-018-0065-4
Thermodynamically immiscible poly(lactic acid) (PLA) and poly(ε-caprolactone) (PCL) were blended and solution-cast by adding the 3% compatibilizer (tributyl citrate, TBC) of the PCL weight. In the PLA/PCL composition range of...
The application of ECG cancellation in diaphragmatic electromyographic by using stationary wavelet transform

Luo G, Yang Z

  • Biomed Eng Lett.
  • 2018 Aug;8(3):259-266.
  • doi: 10.1007/s13534-018-0064-5
In this paper, we present and investigate a special kind of stationary wavelet algorithm using “inverse” hard threshold to eliminate the electrocardiogram (ECG) interference included in diaphragmatic electromyographic (EMGdi). Differing...
Surface morphology characterization of laser-induced titanium implants: lesson to enhance osseointegration process

Tavakoli J, Khosroshahi ME

  • Biomed Eng Lett.
  • 2018 Aug;8(3):249-257.
  • doi: 10.1007/s13534-018-0063-6
The surface properties of implant are responsible to provide mechanical stability by creating an intimate bond between the bone and implant; hence, play a major role on osseointegration process. The...

Go to Top

Copyright © 2020 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr