A Comparison of Central Corneal Thickness Measurements and Measurement Repeatability Using Three Imaging Modalities

Woo SE, Lee SH

Purpose: To compare and analyze central corneal thickness (CCT) measurements and measurement repeatability according to the corneal thickness obtained with anterior segment optical coherence tomography (AS-OCT), ultrasound pachymetry (USP), and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Pericardial Patch Graft Thickness for Glaucoma Implant, Using Anterior Segment Optical Coherence Tomography

Kang MG, Suh JS, Lee YG, Hwang YH

Purpose: To compare the thickness of the processed pericardial patch graft for glaucoma implant tube coverage using anterior segment optical coherence tomography (AS-OCT). Methods: Thicknesses of seven samples of two pericardial...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Laser In Situ Keratomileusis Flap Morphology and Predictability by WaveLight FS200 Femtosecond Laser and Moria Microkeratome: An Anterior Segment Optical Coherence Tomography Study

Eldaly ZH, Abdelsalam MA, Hussein MS, Nassr MA

PURPOSE: To evaluate laser in situ keratomileusis (LASIK) flap thickness predictability and morphology by femtosecond (FS) laser and microkeratome (MK) using anterior segment optical coherence tomography. METHODS: Fifty-two candidates for the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Anterior Segment Parameters Obtained by Anterior Segment Optical Coherence Tomography and Dual Rotating Scheimpflug Camera

Ha DY, Jung JW

PURPOSE: To compare the anterior segment measurements with a Galilei® dual Scheimpflug analyzer and anterior segment optical coherence tomography (Cirrus OCT®). METHODS: Forty-eight eyes of 24 normal young adults were assessed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical and Anterior Segment Anatomical Features in Primary Angle Closure Subgroups Based on Configurations of Iris Root Insertion

Hong JW, Yun SC, Sung KR, Lee JE

PURPOSE: To compare the clinical and anterior segment anatomical features in primary angle closure sub-groups based on configurations of iris root insertion. METHODS: Primary angle closure patients were imaged using anterior...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Utility of the Swept Source Optical Coherence Tomography for Measurements of Central Corneal Thickness

Kim IG, Lee CE, Lee JS, Seo S, Lee KW

PURPOSE: To evaluate the efficacy of swept source optical coherence tomography (SS-OCT) by comparing the measurement of central corneal thickness (CCT) to the measurement obtained using Orbscan II, anterior segment...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Estimation of Intraocular Lens Power Calculation after Myopic Corneal Refractive Surgery: Using Corneal Height in Anterior Segment Optical Coherence Tomography

Kim DH, Kim MK, Wee WR

PURPOSE: To investigate the feasibility of estimating effective lens position (ELP) and calculating intraocular lens power using corneal height (CH), as measured using anterior segment optical coherence tomography (AS-OCT), in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Changes in Area of Conjunctiva and Tear Meniscus Measured Using Anterior Segment Optical Coherence Tomography after Conjunctivochalasis Surgery

Kim JS, Bae JB, Seo JW, Park WC

PURPOSE: To evaluate cross-sectional areas of conjunctiva and tear meniscus of conjunctivochalasis using Fourier-Domain RTVue-100 optical coherence tomography (OCT) before and after conjunctivochalasis surgery. METHODS: Thirty-one patients (33 eyes) with symptomatic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Utility of the Noncontact Specular Microscopy for Measurements of Central Corneal Thickness

Yang YS, Koh JW

  • KMID: 2338591
  • J Korean Ophthalmol Soc.
  • 2014 Jan;55(1):59-65.
PURPOSE: To evaluate the efficacy of noncontact specular microscopy (NCSM) by comparing the measurement of central corneal thickness (CCT) to the measurement with anterior segment optical coherence tomography (AS-OCT) and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Morphological Changes in Main Corneal Incision (2.2 mm vs. 2.8 mm) Evaluated Using Anterior Segment Optical Coherence Tomography

Kim JH, Kim TI, Kim EK, Lee HK

PURPOSE: To investigate wound characteristics and ultrastructural changes in the 2.2-mm and 2.8-mm main corneal incisions. METHODS: Forty-four eyes of 34 patients undergoing cataract surgery were randomized to receive a 2.2-mm...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Location of the Tube Tip in the Anterior Chamber and Change in Corneal Endothelium after Ahmed Valve Implantation

Oh WH, Kim TW, Park KH, Kim DM

PURPOSE: To evaluate the impact of location of a silicone tube tip in the anterior chamber on corneal endothelium after Ahmed glaucoma valve implantation. METHODS: We measured the distance from the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Choice of One-Piece Intraocular Lens Power and Changes of Anterior Chamber in Sulcus Implantation due to Posterior Capsular Rupture during Cataract Surgery

Yang JY, Ma KT, Kim JH

  • KMID: 2338193
  • J Korean Ophthalmol Soc.
  • 2012 Jun;53(6):775-780.
PURPOSE: To evaluate the appropriate correction of predicted intraocular lens (IOL) power when sulcus implantation due to posterior capsular rupture was performed and to compare the anterior chamber angle of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Corneal Thickness Measured by Dual Scheimpflug, Anterior Segment Optical Coherence Tomography, and Ultrasound Pachymetry

Kim DW, Yi KY, Choi DG, Shin YJ

  • KMID: 2338263
  • J Korean Ophthalmol Soc.
  • 2012 Oct;53(10):1412-1418.
PURPOSE: To compare central corneal thickness (CCT) as measured by dual rotating Scheimpflug camera (Galilei), anterior segment optical coherence tomography (AS-OCT), and ultrasound pachymetry (USP). METHODS: The measurements of CCT using...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Change in Angle Parameters Measured by Anterior Segment Optical Coherence Tomography after Laser Peripheral Iridotomy Alone versus Laser Peripheral Iridotomy and Argon Laser Peripheral Iridoplasty

Park HJ, Park KH, Kim SH, Kim TW, Kim DM

PURPOSE: To compare the changes in angle parameters after laser peripheral iridotomy (LPI) alone versus LPI and ALPI (argon laser peripheral iridoplasty) in primary angle closure patients by using anterior...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Flap Thickness Measured with Ultrasound Subtraction Method, Direct Method, and Optical Coherence Tomography

Lee SH, Lee JE, Kim JY, Kim MJ, Tchah HW

PURPOSE: To compare the flap thicknesses measured with the ultrasound (US) subtraction method, the direct method, and optical coherence tomography (OCT) in femtosecond laser-assisted LASIK eyes. METHODS: The present study included...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Changes in Anterior Chamber Depth and Angle After Phacoemulsification measured by Anterior Segment Optical Coherence Tomography

Shin CJ, Lee JE, Kim JY, Tchah HW

  • KMID: 2337807
  • J Korean Ophthalmol Soc.
  • 2010 Mar;51(3):353-358.
PURPOSE: To evaluate changes in anterior chamber depth (ACD) and angle after phacoemulsification and intraocular lens implantation using anterior segment optical coherence tomography (AS-OCT). METHODS: Seventy-eight eyes of 69 patients had...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Detection of Occludable Angles with the Pentacam and the Anterior Segment Optical Coherence Tomography

Hong S, Yi JH, Kang SY, Seong GJ, Kim CY

PURPOSE: To assess efficacy of the Pentacam (PTC) and the anterior segment optical coherence tomography (AOCT) for detection of occludable angles. MATERIALS AND METHODS: Fourty-one eyes with gonioscopically diagnosed occludable...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close