Endoscopically Applied Biodegradable Stent in a Rabbit Model of Pediatric Tracheomalacia

Choi JS, Seok J, Eom MR, Jung E, Park SA, Joo SM, Jun YJ, Son KW, Kwon SK

Objectives. A polydioxanone (PDO) stent was developed to treat tracheomalacia in pediatric patients. However, its safety and efficacy need to be verified in animal studies before clinical trials in patients...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparing the Results of Using Bioabsorbable Magnesium Screw with Those Using a Titanium Screw for the Treatment of Mild to Moderate Hallux Valgus: Short-term Follow-Up

Hong Sy, Kim GL, Han W

Purpose: Hallux valgus (HV) is a common foot deformity that causes pain in the first metatarsophalangeal joint. Distal metatarsal osteotomies are commonly performed as a treatment. This retrospective study compared...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Biodegradable implants for orbital wall fracturereconstruction

Jang HU, Kim SY

Background: Due to the different handling properties of unsintered hydroxyapatite particles/poly- L-lactic acid (uHA/PLLA) and polycaprolactone (PCL), we compared the surgical outcomes and the postoperative implantation accuracy between uHA/PLLA and PCL meshes...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Distinctive bone regeneration of calvarial defects using biphasic calcium phosphate supplemented ultraviolet-crosslinked collagen membrane

Hong I, Khalid AW, Pae HC, Cha JK, Lee JS, Paik JW, Jung UW, Choi SH

PURPOSE: To overcome several drawbacks of chemically-crosslinked collagen membranes, modification processes such as ultraviolet (UV) crosslinking and the addition of biphasic calcium phosphate (BCP) to collagen membranes have been introduced....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical courses and degradation patterns of absorbable plates in facial bone fracture patients

Kim YM, Lee JH

BACKGROUND: Absorbable plates are widely used in open reduction and internal fixation surgeries for facial bone fractures. Absorbable plates are made of polyglycolic acid (PGA), polylactic acid (PLA), polydioxane (PDS),...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Early experience and favorable clinical outcomes of everolimus-eluting bioresorbable scaffolds for coronary artery disease in Korea

Kwon O, Ahn JM, Kang DY, Kang SH, Lee PH, Kang SJ, Lee SW, Kim YH, Lee CW, Park SW, Park DW, Park SJ

BACKGROUND/AIMS: Compared with metallic drug-eluting stents (DES), bioresorbable vascular scaffolds (BVS) may further improve long-term outcomes of percutaneous coronary intervention (PCI) in patients with coronary artery disease. We report our...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Delayed formation of sterile abscess after zygomaticomaxillary complex fracture treatment with bioabsorbable plates

Doh G, Bahk S, Hong KY, Lim S, Han KM, Eo S

We present a patient who showed a sterile abscess after facial bone fixation with bioabsorbable plates and screws. He had zygomaticomaxillary complex and periorbital fracture due to falling down. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Biomechanical Analysis of Biodegradable Cervical Plates Developed for Anterior Cervical Discectomy and Fusion

Cho PG, Ji GY, Park SH, Shin DA

STUDY DESIGN: In-vitro biomechanical investigation. PURPOSE: To evaluate the biomechanical effects of the degeneration of the biodegradable cervical plates developed for anterior cervical discectomy and fusion (ACDF) on fusion and adjacent...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Study on Percutaneous Intramedullary Bioresorbable Pin Fixation for Fourth and Fifth Metacarpal Bone Fracture

Lee SH, Kim SH, Park ES, Nam SM, Shin HS

PURPOSE: Metacarpal fracture of a ring and little finger occurs frequently. Percutaneous intramedullary fixation is a simple and effective method with a low incidence of complications. To date, Kirschner wire...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Efficacy of Bioabsorbable Mesh in Craniofacial Trauma Surgery

Choi WC, Choi HG, Kim JN, Lee MC, Shin DH, Kim SH, Kim CK, Jo DI

BACKGROUND: The ultimate goal of craniofacial reconstructive surgery is to achieve the most complete restoration of facial functions. A bioabsorbable fixation system which does not need secondary operation for implant...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Absorbable Plate-Related Infection after Facial Bone Fracture Reduction

Choi SH, Lee JH

Absorbable plates are used widely for fixation of facial bone fractures. Compared to conventional titanium plating systems, absorbable plates have many favorable traits. They are not palpable after plate absorption,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Treatment of Nonsyndromic Craniosynostosis Using Multi-Split Osteotomy and Rigid Fixation with Absorbable Plates

Nam SB, Nam KW, Lee JW, Song KH, Bae YC

BACKGROUND: Nonsyndromic craniosynostosis is a relatively common craniofacial anomaly and various techniques were introduced to achieve its operative goals. Authors found that by using smaller bone fragments than that used...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Delayed Foreign Body Reaction Caused by Bioabsorbable Plates Used for Maxillofacial Fractures

Jeon HB, Kang DH, Gu JH, Oh SA

BACKGROUND: Bioabsorbable plates and screws are commonly used to reduce maxillofacial bones, particularly in pediatric patients because they degrade completely without complications after bone healing. In this study, we encountered...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Volumetric quantification of bone-implant contact using micro-computed tomography analysis based on region-based segmentation

Kang SW, Lee WJ, Choi SC, Lee SS, Heo MS, Huh KH, Kim TI, Yi WJ

PURPOSE: We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Medial Wall Orbital Reconstruction using Unsintered Hydroxyapatite Particles/Poly L-Lactide Composite Implants

Park H, Kim HS, Lee BI

BACKGROUND: Poly-L-lactide materials combined with hydroxyapatite (u-HA /PLLA) have been developed to overcome the drawbacks of absorbable materials, such as radiolucency and comparably less implant strength. This study was designed...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Absorbable Mesh Plate versus Titanium-Dynamic Mesh Plate in Reconstruction of Blow-Out Fracture: An Analysis of Long-Term Outcomes

Baek WI, Kim HK, Kim WS, Bae TH

BACKGROUND: A blow-out fracture is one of the most common facial injuries in midface trauma. Orbital wall reconstruction is extremely important because it can cause various functional and aesthetic sequelae....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Two-Year Follow-up on the Use of Absorbable Mesh Plates in the Treatment of Medial Orbital Wall Fractures

You JP, Kim DW, Jeon BJ, Jeong SH, Han SK, Dhong ES, Kim WK

BACKGROUND: Absorbable materials offer many advantages in the reconstruction of orbital walls; however, the possibility of postoperative enophthalmos after complete absorption cannot be excluded. We evaluated the postoperative results of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Efficacy of Bioabsorbable Mesh as an Internal Splint in Primary Septoplasty

Kim JN, Choi HG, Kim SH, Park HJ, Shin DH, Jo DI, Kim CK, Uhm KI

Nasal bone fractures are often accompanied by septal fractures or deformity. Posttraumatic nasal deformity is usually caused by septal fractures. Submucosal resection and septoplasty are commonly used surgical techniques for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Absorbable Plate as a Perpendicular Strut for Acute Saddle Nose Deformities

Kim JG, Rhee SC, Cho PD, Kim DJ, Lee SH

BACKGROUND: Nasal pyramid fractures accompanied by saddle nose deformities are not easily corrected by closed reduction. We used an absorbable plate as a perpendicular strut to support the collapsed "keystone...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Results from Over One Year of Follow-Up for Absorbable Mesh Insertion in Partial Mastectomy

Koo MY, Lee SK, Hur SM, Bae SY, Choi MY, Cho DH, Kim S, Choe JH, Kim JH, Kim JS, Lee JE, Nam SJ, Yang JH