A Design Thinking Process with 'Aspie': Developing a New Intervention for People with Asperger's Syndrome

Ryu H, Han G

People with Asperger's syndrome (AS) have a rather different thinking style. They may create new ideas that the designer can see this awkward thinking style as the driver for developing...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development of a Safe Syringe Disposal System Moving towards Automated Syringe Data Collection

Kim Y, Oh K, Kim N, Yun J

OBJECTIVES: An automatic needle destroyer (ANDY) was developed to prevent needlestick injuries, and usability tests were conducted in several hospitals. The addition of extra features to the ANDY is in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Difficulty in Removal of a Femoral Intramedullary Nail: The Geometry of the Distal End of the Nail

Bombaci H, Gorgec M

Different difficulties can be encountered during removal of an intramedullary femoral nail depending partly upon the design of the nail but mainly on bone ingrowth. This possibility is higher in...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Feasibility and Functional Evaluation of Noninvasive Ventilation Capable Equipment from the Delivery Room to Neonatal Intensive Care Unit: A Bench Study

Cho HJ, Kim EJ, Son DW, Jeon IS, Lee JS

OBJECTIVE: The use of noninvasive ventilation (NIV) for newborns requiring respiratory support in delivery room (DR) is recommended. However, the details related to such use are not well established. A...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of Two Novel Integrated Stand-Alone Spacer Designs Compared with Anterior and Anterior-Posterior Single-Level Lumbar Fusion Techniques: An In Vitro Biomechanical Investigation

Kuhns CA, Harris JA, Hussain MM, Muzumdar A, Bucklen BS, Khalil S

STUDY DESIGN: In vitro biomechanical investigation. PURPOSE: To compare the biomechanics of integrated three-screw and four-screw anterior interbody spacer devices and traditional techniques for treatment of degenerative disc disease. OVERVIEW OF LITERATURE:...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bilateral fractures of Hydroflex penile prostheses: an unusual complication

Kim SC, Chang YS, Ahn SY

We report bilaterally fractured Hydroflex implants in 2 patients. One fracture was complete and three were incomplete. All the fractures occurred at the junction of the rear reservoir and the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Effect of Positive End-Expiratory Pressure on Air Leakage: Comparison of Cuff Designs

In J, Shim GS, Chung S

BACKGROUND: Recently developed taper-shaped cuffs (TG cuffs) of endotracheal tubes (ETTs) are known to have a more potent sealing effect than cylindrical high-volume low-pressure cuffs (HL cuffs) of conventional ETTs....
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Interventional Cardiology for Congenital Heart Disease

Kenny D

Congenital heart interventions are now replacing surgical palliation and correction in an evolving number of congenital heart defects. Right ventricular outflow tract and ductus arteriosus stenting have demonstrated favorable outcomes...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The artificial urinary sphincter and male sling for postprostatectomy incontinence: Which patient should get which procedure?

Comiter CV, Dobberfuhl AD

Surgery is the most efficacious treatment for postprostatectomy incontinence. The ideal surgical approach depends on a variety of patient factors including history of prior incontinence surgery or radiation treatment, bladder...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Study of the Pulse Waveform and the Design of the Portable, Non-invasive, Electromagnetic Stimulation for Enhancement of Fracture Healing

Kim YH, Kim WK, Kim SJ

Since the concept of bioelectrical potentials in the bone was developed, various electrical systems have been utilized to heal non-united fractures. The asymmetrical and time varied pulsed electromagnetic stimulator was...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Development and animal study of a pediatric ventricular assist device

Park YH, Kim SH

We have developed a pneumatic type ventricular assist device (VAD) for pediatric use and implanted it in six mongrel dogs to study its efficacy and to identify any problems. The...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of an Experimentally Designed Stereotactic Guidance System for Determining Needle Entry Point during Uniplanar Fluoroscopy-guided Intervention

Lee JH, Jeon GR, Ro JH, Byoen GJ, Kim TK, Kim KH

BACKGROUND: In discography performed during percutaneous endoscopic lumbar discectomy (PELD) via the posterolateral approach, it is difficult to create a fluoroscopic tunnel view because a long needle is required for...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Using the High Frequency Ventilation during Neonatal Transport

Lee SH, Chae MH, Cho HJ, Ryoo E, Shim SY, Son DW

PURPOSE: To present and evaluate a system of high-frequency oscillatory ventilator (HFOV) during intra-/inter-hospital neonate transport. METHODS: The system includes a charged HFOV (SOPHIE, Fritz Stephan GmbH, Dusseldorf, Germany), an incubator,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Cementless Bony lngrowth Total Hip Prosthesis (Anatomical Contact Porous Coated Total Hip Prosthesis) Design using Computed Axial Tomography and Computer Aid Design

Kim YH, Park YP, Suh JS

The purpose of this study is to design an Anatomical Contact Porous Coated Total Hip Prosthesis(ACP) which can transmit stress to the bone more physiologically and which can also eliminate...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
In Vitro Biomechanical and Fluoroscopic Study of a Continuously Expandable Interbody Spacer Concerning Its Role in Insertion Force and Segmental Kinematics

Torretti J, Harris JA, Bucklen BS, Moldavsky , Khalil SE

STUDY DESIGN: In vitro cadaveric study. PURPOSE: To compare biomechanical performance, trial and implant insertion, and disc distraction during implant placement, when two interbody devices, an in situ continuously expandable spacer...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Directional Coronary Atherectomy (Simpson AtheroCath) : Reasons for Device Selection, Angiographic and Histologic Findings, and Its Mechanisms

Park SJ, Park SW, Kim JJ, Song JK, Doo YC, Lee SJ, Yu ES, Gong GY, Lee IC

BACKGROUND: Despite improved operator technique and advanced equipment designs, acute closure and restenosis remain as serious limitations to both the short and long-term success of balloon angioplasty. Atherectomy is a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Breakage of a Lag Screw of Cephalomedullary Nail: A Technique of Removal

Tantigate , Riansuwan , Mahaisavariya B, Sukjaitham K

A broken lag screw of the cephalomedullary nail is a rare condition. Removal of the retained lag screw from the femoral head is also very challenging. This article describes a...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Real-time Emergency Telemedicine System: Prototype Design and Functional Evaluation

Yoo SK, Kim KM, Jung SM, Kim NH, Kim SH, Park JB, Park IC, Oh JH, Kim SH

In this paper, an emergency telemedicine system was designed for the transmission of real-time multimedia for remote consultation, including radiological images, patient records, video-conferencing, full-quality video, ECG, BP, respiration, temperature,...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Purple urine bag syndrome in a patient with a urethral balloon catheter and a history of ileal conduit urinary diversion

Kenzaka T

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

Pausawasadi N, Soontornmanokul T, Rerknimitr R

Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr