Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

17 results
Display

The effect of fibronectin-coated implant on canine osseointegration

Kim S, Myung WC, Lee JS, Cha JK, Jung UW, Yang HC, Lee IS, Choi SH

PURPOSE: The purpose of this study was to characterize the osseointegration of the fibronectin-coated implant surface. METHODS: Sand-blasted, large-grit, acid-etched (SLA) surface implants, with or without a thin calcium phosphate and...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Antimicrobial surfaces for craniofacial implants: state of the art

Actis L, Gaviria L, Guda T, Ong JL

In an attempt to regain function and aesthetics in the craniofacial region, different biomaterials, including titanium, hydroxyapatite, biodegradable polymers and composites, have been widely used as a result of the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Surface characteristics of a novel hydroxyapatite-coated dental implant

Jung UW, Hwang JW, Choi DY, Hu KS, Kwon MK, Choi SH, Kim HJ

PURPOSE: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. METHODS: HA was coated on the titanium implant surface...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bone apposition on implants coated with calcium phosphate by ion beam assisted deposition in oversized drilled sockets: a histologic and histometric analysis in dogs

Kim MS, Jung UW, Kim S, Lee JS, Lee IS, Choi SH

PURPOSE: The purpose of this study was to evaluate the osseointegration of calcium phosphate (CaP)-coated implants by ion beam assisted deposition with a lack of primary stability. METHODS: A total of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Osteoblastic behavior to zirconium coating on Ti-6Al-4V alloy

Lee BA, Kim HJ, Xuan YZ, Park YJ, Chung HJ, Kim YJ

PURPOSE: The purpose of this study was to assess the surface characteristics and the biocompatibility of zirconium (Zr) coating on Ti-6Al-4V alloy surface by radio frequency (RF) magnetron sputtering method. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effect of magnesium and calcium phosphate coatings on osteoblastic responses to the titanium surface

Park KD, Lee BA, Piao XH, Lee KK, Park SW, Oh HK, Kim YJ, Park HJ

PURPOSE: The aim of this study was to evaluate the surface properties and in vitro bioactivity to osteoblasts of magnesium and magnesium-hydroxyapatite coated titanium. MATERIALS AND METHODS: Themagnesium (Mg) and magnesium-hydroxyapatite...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bioactive characteristics of an implant surface coated with a pH buffering agent: an in vitro study

Pae HC, Kim SK, Park JY, Song YW, Cha JK, Paik JW, Choi SH

PURPOSE: The purpose of this study was to evaluate the effectiveness of conventional sandblasted, large-grit, acid-etched (SLA) surface coated with a pH buffering solution based on surface wettability, blood protein...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Correspondence Re: Recanalization of an Occluded Intrahepatic Portosystemic Covered Stent via the Percutaneous Transhepatic Approach

Haskal ZJ

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Revision Total Hip Arthroplasty Using an Extensively Porous Coated Femoral Stem

Moon KH, Kang JS, Lee SH, Jung SR

BACKGROUND: To determine the benefit of an extensively porous coated femoral stem in patients receiving revision total hip arthroplasty. METHODS: This study reviewed the results of 35 patients who received...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fibrovascularization of Intraorbital Hydroxyapatite-Coated Alumina Sphere in Rabbits

Chung WS, Song SJ, Lee SH, Kim EA

We investigated the fibrovascular ingrowth and fibrovascular tissue maturation of hydroxyapatite-coated, porous alumina sphere (Alumina sphere) in comparison with the hydroxyapatite sphere (HAp sphere) in rabbits. Alumina spheres and HAp...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fifteen-year Results of Precoated Femoral Stem in Primary Hybrid Total Hip Arthroplasty

Suh DH, Yun HH, Chun SK, Shon WY

BACKGROUND: There has been controversy whether methylmethacrylate precoating of the cemented femoral stem is a solution for aseptic loosening or rather contributes to increased failure rates in cemented total hip...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Local Delivery of Nitric Oxide from an Eluting Stent to Inhibit Neointimal Thickening in a Porcine Coronary Injury Model

Yoon JH, Wu CJ, Homme J, Tuch RJ, Wolff RG, Topol EJ, Lincoff AM

To assess the effect of a NO-eluting stent on reducing neointimal thickening in a porcine coronary artery stent injury model, sodium nitroprusside (SNP), a NO donor, was incorporated into polyurethane...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Seven-year Results of a Tapered, Titanium, Hydroxyapatite-Coated Cementless Femoral Stem in Primary Total Hip Arthroplasty

Cho JH, Garino JP, Choo SK, Han KY, Kim JH, Oh HK

BACKGROUND: Aseptic loosening of cemented hip prostheses is recognized as a long-term problem, and especially in males and younger patients. Much energy has been focused on developing new prostheses that...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Long-term Clinical Results of a Platelet Glycoprotein IIb/IIIa Receptor Blocker (Abciximab: ReoPro (R) ) Coated Stent in Patients with Coronary Artery Disease

Kim W, Jeong MH, Hong YJ, Lee SH, Park WS, Kim JH, Kim IS, Choi MJ, Ahn YK, Cho JG, Park JC, Cho DL, Kim H, Kang JC

  • KMID: 1109520
  • Korean J Intern Med.
  • 2004 Dec;19(4):220-229.
BACKGROUND: Previously, the inhibition of coronary restenosis with Abciximab (ReoPro (R) ) -coated stent in a porcine model was reported. ReoPro (R) inhibits platelet aggregation, the proliferation of vascular smooth...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Recent Advances of Biliary Stent Management

Kida M, Miyazawa S, Iwai T, Ikeda H, Takezawa M, Kikuchi H, Watanabe M, Imaizumi H, Koizumi W

Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Even we employed metallic stents which contributed to higher...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks

Pausawasadi N, Soontornmanokul T, Rerknimitr R

Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Treatment of Malignant Biliary Obstruction with a PTFE-Covered Self-Expandable Nitinol Stent

Han YM, Kwak HS, Jin GY, Lee SO, Chung GH

OBJECTIVE: We wanted to determine the technical and clinical efficacy of using a PTFE-covered self-expandable nitinol stent for the palliative treatment of malignant biliary obstruction. MATERIALS AND METHODS: Thirty-seven...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr