Skip Navigation
Skip to contents
Results by Year

View Wide

Filter

ARTICLE TYPE

more+
SELECT FILTER
 
Close

PUBLICATION DATE

123 results
Display

Recent Advances of Biliary Stent Management

Kida M, Miyazawa S, Iwai T, Ikeda H, Takezawa M, Kikuchi H, Watanabe M, Imaizumi H, Koizumi W

Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Even we employed metallic stents which contributed to higher...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Successful management of colonic perforation with a covered metal stent

Kim SW, Lee WH, Kim JS, Lee HN, Kim SJ, Lee SJ

Self-expandable stents are widely available for the treatment of perforation of the gastrointestinal tract. Because of the risk of migration, there has been no report of the use of self-expandable...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Is There Room for Improvement in Increasing the Stent Patency of Biliary Plastic Stents?

Choe JW, Hyun JJ

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Can improvements in our physiological understanding yield information on the utility of endothelial progenitor cell capture stents?

Kang HJ

No abstract available.
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Two dislodged and crushed coronary stents: treatment of two simultaneously dislodged stents using crushing techniques

Yang DH, Woo SI, Kim DH, Park SD, Jang JH, Kwan J, Shin SH

Coronary stent dislodgement is a rare complication of percutaneous coronary intervention. We report a rare case of dislodgement of two intracoronary stents. On withdrawal of two balloon catheters, one with...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Clinical Outcomes of Ahmed Glaucoma Valve Implantation Using Tube Ligation and Removable External Stents

Lee JJ, Park KH, Kim DM, Kim TW

PURPOSE: To investigate the immediate and long-term outcomes of Ahmed glaucoma valve (AGV) implantation with silicone tube ligation and removable external stents. METHODS: This retrospective non-comparative study investigated the outcomes...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Interventional Management of Esophagorespiratory Fistula

Shin JH, Kim JH, Song HY

An esophagorespiratory fistula (ERF) is an often fatal consequence of esophageal or bronchogenic carcinomas. The preferred treatment is placement of esophageal and/or airway stents. Stent placement must be performed as...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Interventional Management of Malignant Colorectal Obstruction: Use of Covered and Uncovered Stents

Choi JS, Choo SW, Park KB, Shin SW, Yoo SY, Kim JH, Do YS

Objective: We wanted to evaluate usefulness of uncovered stent in comparison with covered stent for the palliative treatment of malignant colorectal obstruction. Materials and Methods: Covered (n = 52, type...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Bile Flow Phantom Model and Animal Bile Duct Dilation Model for Evaluating Biliary Plastic Stents with Advanced Hydrophilic Coating

Kwon CI, Kim G, Jeong S, Lee WS, Lee DH, Ko KH, Hong SP, Hahm KB

BACKGROUND/AIMS: The efforts to improve biliary plastic stents (PSs) for decreasing biofilm formation and overcome short patency time have been continued. The aim of this study is to evaluate the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Evaluation of the Biodurability of Polyurethane-Covered Stent Using a Flow Phantom

Kim DH, Kang SG, Choi JR, Byun JN, Kim YC, Ahn YM

OBJECTIVE:To evaluate the biodurability of the covering material in retrievable metallic stents covered with polycarbonate polyurethane. MATERIALS AND METHODS: Using a peristaltic pump at a constant rate of 1ml/min, bile...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Local Delivery of Nitric Oxide from an Eluting Stent to Inhibit Neointimal Thickening in a Porcine Coronary Injury Model

Yoon JH, Wu CJ, Homme J, Tuch RJ, Wolff RG, Topol EJ, Lincoff AM

To assess the effect of a NO-eluting stent on reducing neointimal thickening in a porcine coronary artery stent injury model, sodium nitroprusside (SNP), a NO donor, was incorporated into polyurethane...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Optimization of Stent Deployment by Intravascular Ultrasound

Yoon HJ, Hur SH

Intravascular ultrasound (IVUS) is a useful diagnostic method that provides valuable information in addition to angiography regarding the coronary vessel lumen, dimensions, plaque burden, and characteristics. The major use of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Efficacy of a Dexamethasone-Eluting Nitinol Stent on the Inhibition of Pseudointimal Hyperplasia in a Transjugular Intrahepatic Portosystemic Shunt: An Experimental Study in a Swine Model

Seo TS, Oh JH, Park YK, Song HY, Park SJ, Yuk SH

OBJECTIVE: We wanted to evaluate the feasibility and efficacy of using a dexamethasone (DM) -eluting nitinol stent to inhibit the pseudointimal hyperplasia following stent placement in the transjugular intrahepatic portosystemic...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
A Unique Use of a Double-Pigtail Plastic Stent: Correction of Kinking of the Common Bile Duct Due to a Metal Stent

Kuwatani M, Kawakami H, Abe Y, Kawahata S, Kawakubo K, Kubo K, Sakamoto N

A 72-year-old man with jaundice by ampullary adenocarcinoma was treated at our hospital. For biliary decompression, a transpapillary, fully covered, self-expandable metal stent (FCSEMS) was deployed. Four days later, the...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Comparison of Effects of Preoperative Stenting for Obstructing Colorectal Cancers according to the Location of the Obstructing Lesion

Kim JS, Oh SY, Seo KU, Lee MH, Cheon SJ, Im HC, Kim JH, Lee KJ

BACKGROUND/AIMS: With the development of self-expanding metallic stents, colonic obstruction can be relieved without the need for surgery. The results of preoperative placement of stents for malignant colorectal obstruction might...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

Sun Z, Chaichana

OBJECTIVE: We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. MATERIALS AND METHODS: Two representative patients who each had...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Impact of an endothelial progenitor cell capturing stent on coronary microvascular function: comparison with drug-eluting stents

Choi WG, Kim SH, Yoon HS, Lee EJ, Kim DW

BACKGROUND/AIMS: Although drug-eluting stents (DESs) effectively reduce restenosis following percutaneous coronary intervention (PCI), they also delay re-endothelialization and impair microvascular function, resulting in adverse clinical outcomes. Endothelial progenitor cell (EPC)...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
The Usefulness of Clip Application in Preventing Migration of Self-expandable Metal Stent in Patients with Malignant Gastrointestinal Obstruction

Park SY, Park CH, Cho SB, Lee JS, Joo SY, Park HC, Lee WS, Joo YE, Kim HS, Choi SK, Rew JS, Kim SJ

  • KMID: 782812
  • Korean J Gastroenterol.
  • 2007 Jan;49(1):4-9.
BACKGROUND/AIMS: Management of malignant gastrointestinal obstruction presents a significant challenge. Recently, self-expandable metal stent (SEMS) has emerged as an effective, safe, and less invasive alternative for the treatment of...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Percutaneous Placement of Self-expandable Metallic Biliary Stents in Malignant Extrahepatic Strictures: Indications of Transpapillary and Suprapapillary Methods

Lee DH, Yu JS, Hwang JC, Kim KH

OBJECTIVE: To compare the efficacy of suprapapillary and transpapillary meth-ods of transhepatic biliary metallic stent placement in malignant biliary strictures and to specify the indications of each method applied. MATERIALS...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close
Effectiveness of Drug-Eluting Stents versus Bare-Metal Stents in Large Coronary Arteries in Patients with Acute Myocardial Infarction

Sim DS, Jeong MH, Ahn Y, Kim YJ, Chae SC, Hong TJ, Seong IW, Chae JK, Kim CJ, Cho MC, Seung KB, Park SJ, other Korea Acute Myocardial Infarction Registry (KAMIR) Investigators

This study compared clinical outcomes of drug-eluting stents (DES) versus bare-metal stents (BMS) in large coronary arteries in patients with acute myocardial infarction (MI). A total of 985 patients who...
CITED
export Copy
Close
SHARE
Twitter Facebook
Close

Go to Top

Copyright © 2024 by Korean Association of Medical Journal Editors. All rights reserved.     E-mail: koreamed@kamje.or.kr